Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    .37 KW MOTOR Search Results

    .37 KW MOTOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TB67H451AFNG Toshiba Electronic Devices & Storage Corporation Brushed Motor Driver/1ch/Vout(V)=50/Iout(A)=3.5 Visit Toshiba Electronic Devices & Storage Corporation
    TB67H450AFNG Toshiba Electronic Devices & Storage Corporation Brushed Motor Driver/1ch/Vout(V)=50/Iout(A)=3.5 Visit Toshiba Electronic Devices & Storage Corporation
    TB67S580FNG Toshiba Electronic Devices & Storage Corporation Stepping Motor Driver/Unipolar Type/Vout(V)=50/Iout(A)=1.6 Visit Toshiba Electronic Devices & Storage Corporation
    TB67S581FNG Toshiba Electronic Devices & Storage Corporation Stepping Motor Driver/Unipolar Type/Vout(V)=50/Iout(A)=2.5 Visit Toshiba Electronic Devices & Storage Corporation
    TB67B001BFTG Toshiba Electronic Devices & Storage Corporation Brushless Motor Driver/3 Phases Driver/Vout(V)=25/Iout(A)=3/Square Wave Visit Toshiba Electronic Devices & Storage Corporation

    .37 KW MOTOR Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    PKZM4-58

    Abstract: pkzm4 VDE 0660 IP 65
    Text: Type: PKZM4−58 Article No.: 222394 Ordering information Connection technique Screw terminals Motor rating AC−3 220 V 230 V 240 V P kW 17 Motor rating AC−3 380 V 400 V 415 V P kW 30 Motor rating AC−3 440 V P kW 37 Motor rating AC−3 500 V P kW 37 Motor rating AC−3 690 V


    Original
    PDF PKZM4-58 D-53115 HPL-C2006GB-INT PKZM4-58 pkzm4 VDE 0660 IP 65

    PKZM4-63

    Abstract: Moeller PKZM4-63
    Text: Type: PKZM4−63 Article No.: 222413 Ordering information Connection technique Screw terminals Motor rating AC−3 220 V 230 V 240 V P kW 18.5 Motor rating AC−3 380 V 400 V 415 V P kW 34 Motor rating AC−3 440 V P kW 37 Motor rating AC−3 500 V P kW 45


    Original
    PDF PKZM4-63 D-53115 HPL-C2006GB-INT PKZM4-63 Moeller PKZM4-63

    klixon start relay motor

    Abstract: sensor PT1000 temperature sensor PT1000 5kw sine wave inverter klixon relay PT1000 thermistor 5kw inverter circuit klixon ptc relay Klixon 2kw pure sine wave power inverter
    Text: 2002-04-10 PRODUKTINFORMATION Vi reserverar oss mot fel samt förbehåller oss rätten till ändringar utan föregående meddelande ELFA artikelnr 37-646-10 NFO Frekvensomriktare 370W 37-646-28 NFO Frekvensomriktare 750W 37-646-36 NFO Frekvensomrik. 1,5 kW


    Original
    PDF

    230V 5A OMRON Auxiliary RELAY

    Abstract: star delta wiring diagram with pneumatic timer 220-240v varistor 230V 5A OMRON RELAY NC Contacts J73KN-b-01 transformer winding formula 220v Ac to 110v Ac 3phase winding data 3.7 kw to 110 kw J7KN-14-10 AC415-440V timer omron J74KN-LG-9030
    Text: Motor Contactor J7KN Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 37 kW • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof (BGV A2) • System contactors for Fuseless Load Feeders with integrated


    Original
    PDF 380/415V) omron247 J06E-EN-01A 230V 5A OMRON Auxiliary RELAY star delta wiring diagram with pneumatic timer 220-240v varistor 230V 5A OMRON RELAY NC Contacts J73KN-b-01 transformer winding formula 220v Ac to 110v Ac 3phase winding data 3.7 kw to 110 kw J7KN-14-10 AC415-440V timer omron J74KN-LG-9030

    3phase winding data 3.7 kw to 110 kw

    Abstract: feeder J74-WKR-B J7KN24 DOL reversing wiring diagram motor J7KNG-22-4 wiring diagram 3 phase dol compressor magnetic Contactor wiring diagrams J7KN14-01 J74KN-C-RC24
    Text: Motor Contactor J7KN • Range from 4 to 500 kW AC 3, 380/415 V • AC and DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting (35 mm DIN rail) upto 37 kW • Compliant to the global standards • Finger proof (BGV A2) • System contactors for Fuseless Load Feeders with integrated


    Original
    PDF J74KN-C-RC J74KN-B-RC J74KN-LG-9030 J74KN-LG-11224 J74KN-LG-10404 J74KN-LG-11457 J74KN-P J74-WKR-B J74-WKR-C J74-WKSD-B 3phase winding data 3.7 kw to 110 kw feeder J7KN24 DOL reversing wiring diagram motor J7KNG-22-4 wiring diagram 3 phase dol compressor magnetic Contactor wiring diagrams J7KN14-01 J74KN-C-RC24

    ACS100-PAN

    Abstract: acs-chk-c abb acs 101 NPBA-02 PEC-98-0008 SACL22 NOCH-0070-6X NCAN-02 334 te 2395 acs 143
    Text: Technical Catalogue Instant ordering and advice Low power AC drives 0.12 kW - 37 kW Easy to pay, most credit cards accepted Fast delivery within hours Simple documentation easy to read Support line 2 year worldwide warranty ABB Automation 1 Nobody looks after you better. Every drive you buy comes with


    Original
    PDF R0225 ACS100-PAN acs-chk-c abb acs 101 NPBA-02 PEC-98-0008 SACL22 NOCH-0070-6X NCAN-02 334 te 2395 acs 143

    rj12 rs485

    Abstract: 10 HP CAPACITOR START SINGLE PHASE motor WIRING DIAGRAM RJ12 to RS485 edr40 RJ12 connector
    Text: Prices as of April 16, 2014. Check Web site for most current prices. DURApulse AC Drives – Introduction DURApulse Drives Motor Rating Hp 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 kW .75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 Single/Three-Phase Input 230V 4 4 4


    Original
    PDF 230VClass RS-485 SJ100-055HFU GS2-47P5 GS3-47P5 SJ100-075HFU GS2-4010 GS3-4010 eDR-95 rj12 rs485 10 HP CAPACITOR START SINGLE PHASE motor WIRING DIAGRAM RJ12 to RS485 edr40 RJ12 connector

    LC1-D09

    Abstract: dimension LC1-D09 LC1-D25 LC1-D09 installation manual LC1-D25 wiring LC1-D2500 LP1-D09 380V 415v motor LC1 D25008 LP1-D25
    Text: Motor Control Device 1-1 Magnetic latching contactors GCR1-F series magnetic latching contactors Magnetic latching contactors of both block and bar mounted types are fitted with a special electromagnet which enables them to remain in the "On" position when the coil is no longer energised.


    Original
    PDF GLE1-D09 GLE1-D018 GLE1-D25 GLE1-D32 GLE1-D40 GLE1-D95 LC1-D09 dimension LC1-D09 LC1-D25 LC1-D09 installation manual LC1-D25 wiring LC1-D2500 LP1-D09 380V 415v motor LC1 D25008 LP1-D25

    pst44

    Abstract: PSTB720-600-70 PSTB470-600-70 PSTB570-600-70 PST250-600-70 PSTB370-600-70 1SFT98000-012C3 DNP21-FBP PST72-600-70 PSS25-400B
    Text: Mykstartere Type PSS Type PST/PSTB - New range Ny 1SFC132016F0201 Katalog 1SEC132001C2101, Juli 2003 PSS03 . PSS25 For normal starts Operator panels Application PSS25 The softstarter types PSS03 . PSS25 are compact solutions for small motors. It is easy to install and to adjust as access for connections and


    Original
    PDF 1SFC132016F0201 1SEC132001C2101, PSS03 PSS25 PSS25 PSS12 pst44 PSTB720-600-70 PSTB470-600-70 PSTB570-600-70 PST250-600-70 PSTB370-600-70 1SFT98000-012C3 DNP21-FBP PST72-600-70 PSS25-400B

    LC1 D09 10

    Abstract: LC1D40A tesys d contactors LC1 D12 P7 D65A LC1 D09 BD LC2-D12 LC1-D40A LC1 D38 LC2-D09
    Text: TeSys contactors References 526172 TeSys D, 3-pole reversing contactors for motor control up to 75 kW at 400 V, in category AC-3 Horizontally mounted, pre-assembled 3-pole reversing contactors for connection by screw clamp terminals Pre-wired power connections.


    Original
    PDF D12pp kW/400 24503-EN LC1 D09 10 LC1D40A tesys d contactors LC1 D12 P7 D65A LC1 D09 BD LC2-D12 LC1-D40A LC1 D38 LC2-D09

    194E-A125-1754

    Abstract: 194E-A250-1753 194E-B250-1753 194E 194E-E125-1753 DC22A 194ehe8g175 194E-A160-1753 194E-AB AC21A
    Text: IEC Load Switches Bulletin 194E 125 Amps to 315 Amps Features • • • • • • • • • • Description Bulletin 194E load switches are designed for use in North America as local motor isolation and for IEC disconnect switch applications outside of North America. Available in 3- and 4-pole versions with


    Original
    PDF 194Es 194E-HE-8A-8I-8G-8N) 194E-HE-13A-13I-13G-13N) G3515 194E-A125-1754 194E-A250-1753 194E-B250-1753 194E 194E-E125-1753 DC22A 194ehe8g175 194E-A160-1753 194E-AB AC21A

    schneider LC1-D38

    Abstract: LC1-D38 LC1-D09 LC1-D123 lc1d128 LC1-D093 LC1D09 schneider LC1-DT25 schneider LC1-D258 schneider LC1-D09
    Text: References TeSys contactors For motor control up to 75 kW at 400 V, in category AC-3 Control circuit: a.c., d.c. or low consumption 810356 3-pole contactors for connection by screw clamp terminals or connectors Standard power ratings of 3-phase motors 50/60 Hz in category AC-3


    Original
    PDF LC1-D09// LC1-D12// LC1-D18// LC1-D25// LC2-DT20. schneider LC1-D38 LC1-D38 LC1-D09 LC1-D123 lc1d128 LC1-D093 LC1D09 schneider LC1-DT25 schneider LC1-D258 schneider LC1-D09

    bva04

    Abstract: D656 tesys d contactors K065 D406 D806 M7230 IEC 60439-1 start return ac motors LE4-D09
    Text: TeSys enclosed starters Characteristics, references 2 2 D.O.L. starters for motor control 1 2.2 to 45 kW, with isolating device Characteristics Conforming to standards IEC 60947-4-1 and IEC 60439-1, VDE 0660-102, EN 60947 Ambient air temperature IP 659: LEp K


    Original
    PDF D09907 D09F7A04. 24103-EN bva04 D656 tesys d contactors K065 D406 D806 M7230 IEC 60439-1 start return ac motors LE4-D09

    DIL00AM

    Abstract: DIL4M115 DIL3AM85 dil00m DIL4AM145 DIL00BM-10 DIL00M-10 DIL00M-G dil3m80 DIL2AM-G
    Text: I06_012-013_b_gb.fm Seite 12 Dienstag, 18. März 2003 1:27 13 6/12 Moeller HPL0211-2003/2004 3-pole Screw terminals DIL contactors 3-pole, 4-pole basic units Rated operational current AC-3 380 V 400 V Ie A Max. rating for three-phase motors, 50 – 60 Hz AC-3


    Original
    PDF HPL0211-2003/2004 DIL3M80 24VDC) DIL3AM85 DIL4M115 230V50HZ) DIL4AM145 DIL00AM dil00m DIL00BM-10 DIL00M-10 DIL00M-G DIL2AM-G

    22-HIM-A3

    Abstract: AK-R2-360P500 22-HIM-C2S 20AC015A0AYNANC0 22A D4P0N104 Powerflex User Manual wireless 3-phase starter using rf technology wireless 3-phase motor starter using RF technology 20b-enc-1 22F-A4P2N103 140M-F8E-C45
    Text: SELECTION GUIDE POWERFLEX AC DRIVES THE INTELLIGENT MOTOR CONTROL SOLUTION FOR YOUR APPLICATION REQUIREMENTS AUTOMOTIVE BREWING BEVERAGE FOOD PACKAGING PHARMACEUTICAL PETROCHEMICAL WATER WASTEWATER MINING AGGREGATE CEMENT OIL & GAS PRINTING & PUBLISHING


    Original
    PDF PFLEX-SG102E-EN-P PFLEX-SG102D-EN-P 22-HIM-A3 AK-R2-360P500 22-HIM-C2S 20AC015A0AYNANC0 22A D4P0N104 Powerflex User Manual wireless 3-phase starter using rf technology wireless 3-phase motor starter using RF technology 20b-enc-1 22F-A4P2N103 140M-F8E-C45

    LC1 D38

    Abstract: lc1 f265 LC1 F400 LC1-k16 LP1 K12 contactor LC1-D25 Lc1 f630 LP1 K09 LC1-D09 LC1-D18
    Text: Selection 5 TeSys contactors 5 For utilisation category AC-3 Operational current and power conforming to IEC θ y 60 °C 1 Contactor size Maximum operational current in AC-3 Rated operational power P (standard motor power ratings) 2 3 y 440 V A LC1/ LP1


    Original
    PDF

    LC1-D50A

    Abstract: LC1D40A schneider LC1-D09 LC1-DWK12 LC1D65A LC1-D09 LAD4TBDL LC1-D18 LC1-D09 installation manual LC1-D12
    Text: Motor control 1 TeSys range provide you more simplicity, compactness, openness and flexibility . so many evolutions and new items to aid your productivity. 2 Accurate and reliable control of motors 3 4 5 6 7 Increase your productivity, adopt our solutions which help to simplify


    Original
    PDF LC1-F630, F6304 LC1-F500 F5004 LC1-F400 F4004 LC1-D50A LC1D40A schneider LC1-D09 LC1-DWK12 LC1D65A LC1-D09 LAD4TBDL LC1-D18 LC1-D09 installation manual LC1-D12

    siemens soft starter 3rw44

    Abstract: Sirius 3Rv siemens star delta starter 3RW44 siemens soft starter Sirius 3RW40 3RW4900-0KC00 star delta motor starter with siemens contactor 3RW444 3UF7940-0AA00-0
    Text: Siemens AG 2008 Dynamics Reinterpreted The Comprehensive Range of SIRIUS Soft Starters www.siemens.com/softstarter © Siemens AG 2008 The Ideal SIRIUS Soft Starter for All Applications Today, three-phase motors serve as the ultimate drive concept. Yet, for many


    Original
    PDF E20001-A1040-P302-X-7600 21C/9315 siemens soft starter 3rw44 Sirius 3Rv siemens star delta starter 3RW44 siemens soft starter Sirius 3RW40 3RW4900-0KC00 star delta motor starter with siemens contactor 3RW444 3UF7940-0AA00-0

    50 KW dc motor

    Abstract: 3 Kw ac motor control 90 KW motor 15 kw series dc motor IEC 60947-3 MOELLER
    Text: Type: T5B−1−8210/I4 Article No.: 207432 With black thumb−grip and grey front plate Ordering information Design Surface mounting Description With 0 Off position No. of poles M 1 Max. three−phase motor rating (per set of 3 contacts) 50−60 Hz AC−3 400/415


    Original
    PDF T5B-1-8210/I4 T8-3-8342/. AC-21A D-53115 HPL-C2006GB-INT 50 KW dc motor 3 Kw ac motor control 90 KW motor 15 kw series dc motor IEC 60947-3 MOELLER

    AC-21A

    Abstract: No abstract text available
    Text: Type: P3−63/I4 Article No.: 207356 Ordering information Design Surface mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P3-63/I4 AC-21A D-53115 HPL-C2006GB-INT

    3phase winding data 3.7 kw to 110 kw

    Abstract: J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v
    Text: Motor Contactor J7KN Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessories • front mounted single pole additional auxiliary contacts


    Original
    PDF 380/415V) J7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v

    3phase winding data 3.7 kw to 110 kw

    Abstract: 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor
    Text: Motor Contactor Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW W • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessoires • front mounted d single pole additional auxiliary contacts


    Original
    PDF 380/415V) Conta7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor

    2090-XXNFMF-Sxx

    Abstract: servo srm 102 2090-CDNFDMP-Sxx 2090-K6CK-D15M DIN748 SNS-60 8720SM 2090-K6CK 12v DC geared motor 12v 30 RPM DC geared motor
    Text: Technical Data 8720SM Motor Conversions Catalog Numbers 8720SM-005, 8720SM-007, 8720SM-011, 8720SM-015, 8720SM-018, 8720SM-022, 8720SM-030, 8720SM-037, 8720SM-045, 8720SM-055, 8720SM-063, 8720SM-075, 8720SM-093 Topic Page About This Publication 2 About Converting from 8720SM Motors


    Original
    PDF 8720SM 8720SM-005, 8720SM-007, 8720SM-011, 8720SM-015, 8720SM-018, 8720SM-022, 8720SM-030, 8720SM-037, 8720SM-045, 2090-XXNFMF-Sxx servo srm 102 2090-CDNFDMP-Sxx 2090-K6CK-D15M DIN748 SNS-60 2090-K6CK 12v DC geared motor 12v 30 RPM DC geared motor

    star-delta starting motors

    Abstract: Moeller P1-32 moeller dol starters T5B-4-15682 T3-4-15682 p1-32 i2 svb moeller SDAINLM70 SDAINLM115 dol starter ip65 Moeller SDAINLM12
    Text: www.moeller.co.uk Enclosed Motor Starters & Isolators Short Form Catalogue A We keep power under control. 2 Enclosed motor starters and isolators Contents Contents Enclosed motor starters Direct-on-line – compact 3 4 Direct-on-line – insulated enclosures


    Original
    PDF 21-270GB star-delta starting motors Moeller P1-32 moeller dol starters T5B-4-15682 T3-4-15682 p1-32 i2 svb moeller SDAINLM70 SDAINLM115 dol starter ip65 Moeller SDAINLM12