Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    108SERIES Search Results

    108SERIES Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    LGA 1207 socket F

    Abstract: pcb warpage after reflow pcb warpage* in smt reflow amd socket 1207 MMC socket Socket-F Tyco LGA 1207 socket F datasheet SN63 PB37 THERMO PROFILES transistor 1207 PEAK tray drawing
    Text: SOCKET F 1207 Application Specification 114-5383 7 MAY ‘07 Rev.C 1. INTRODUCTION This specification covers the requirements for application of lever-actuated Socket F 1207 position onto printed circuit (pc) boards. These sockets accept 1207-position LGA package


    Original
    1207-position LGA 1207 socket F pcb warpage after reflow pcb warpage* in smt reflow amd socket 1207 MMC socket Socket-F Tyco LGA 1207 socket F datasheet SN63 PB37 THERMO PROFILES transistor 1207 PEAK tray drawing PDF

    25003

    Abstract: pneumatic arm CHAMPOMATOR 2.5 BENCH TERMINATING MACHINE flat ribbon cable notcher SN60 SN62 408-6790 408-series
    Text: Application Specification 114- 25032 AMPMODU* Mass Termination MT Interconnection System NOTE i 23 OCT 09 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.


    Original
    PDF

    am2 SOCKET PIN LAYOUT

    Abstract: socket 940 am2 pin socket am2 am2 socket pin out socket 939 socket 940 socket AM2 retention AM2 socket data MMC socket tl081 datasheets
    Text: APPLICATION SPECIFICATION 114-13092 LEVER-ACTUATED ZERO INSERTION FORCE ZIF MICRO PIN GRID ARRAY (PGA) SOCKETS 940, 939 & AM2 NOTE : 1. All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimetres. Unless otherwise specified,


    Original
    AMP-QA-183 am2 SOCKET PIN LAYOUT socket 940 am2 pin socket am2 am2 socket pin out socket 939 socket 940 socket AM2 retention AM2 socket data MMC socket tl081 datasheets PDF

    Height gage

    Abstract: msds light yellow E81956 sealant 79016
    Text: Application Specification 114- 6010 Tel- Splice Connectors NOTE i 16 SEP 09 Rev E All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.


    Original
    PDF

    466779

    Abstract: 408-6976 Tyco AMP document 408-6976 58080-3 Tyco faston insulated proper hand crimping procedure 408-9902 B 722 P UL-310 Tyco (AMP) document 408-6976 AMP crimper 69710-1 408-2095
    Text: Application Specification Ultra- Fast Series 110, 125, 187, 205, and 250 Fully- Insulated FASTON* Terminals NOTE i 114- 2123 02 OCT 09 Rev F All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: MULTILOCK* 040/070 and 070/250 Series Hybrid Connectors NOTE i Application Specification 114- 8005 20 APR 11 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.


    Original
    040--series 070--series PDF

    tyco 114-25026

    Abstract: 58342-1 6414 tube LR7189 SN60 SN62 408-7424 tube 6922 Alpha 611 RMA msds CRIMPING
    Text: Application Specification 114- 25026 AMPMODU* MTE Interconnection System NOTE i 15 FEB 10 Rev D All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.


    Original
    PDF

    LGA1366

    Abstract: 1981467-1 LGA-1366 LGA rework Socket 1366 reflow profiles MMC socket socket LGA 1366 PEAK tray drawing X-1981837-X pcb warpage* in smt reflow
    Text: Lever Actuated Land Grid Array LGA1366 Socket Application Specification 114-5432 24 Sep ’08 Rev.A 1. INTRODUCTION This specification covers the requirements for application of lever-actuated LGA1366 Socket position onto printed circuit board PCB . The socket accepts 1366-position LGA


    Original
    LGA1366 LGA1366 1366-position 016mm Table12. Table12 1981467-1 LGA-1366 LGA rework Socket 1366 reflow profiles MMC socket socket LGA 1366 PEAK tray drawing X-1981837-X pcb warpage* in smt reflow PDF

    911788-2

    Abstract: B1115 kester 5778 91173 JIS B1122 114-5159 III-G AMPOMATOR 75543 408-9640 B1122
    Text: MULTILOCK* 040/070 and 070/250 Series Hybrid Connectors NOTE i Application Specification 114- 8005 02 NOV 09 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.


    Original
    040--series 070--series 911788-2 B1115 kester 5778 91173 JIS B1122 114-5159 III-G AMPOMATOR 75543 408-9640 B1122 PDF

    D2186

    Abstract: def5134 DEF5134-1 17151 622j
    Text: Electrolytic capacitors book 3 part 1 long life. small 108Series to I.E.C. 103 Type 1 Typ e No. 10813151 108 13331 10813471 10813102 108 13152 10813222 10814101 108 14221 108 14331 108 14681 10 8 14102 108 14152 108 15689 108 15151 10 8 1 5 2 2 1 108 15471


    OCR Scan
    108Series 100Hz, D2186 DEF5134-1 def5134 DEF5134-1 17151 622j PDF