Untitled
Abstract: No abstract text available
Text: SPECIFICATION FOR APPROVAL REF. : SS0906□□□□L□-□□□ ABC'S DWG NO. PROD. Shielded SMD Power Inductor NAME REV. 20130109-B PAGE 1 Ⅰ﹒Configuration and dimensions: 1 8 B 101 Marking 4 5 Dot is start winding & Inductance code C A F F' 10.3
|
Original
|
PDF
|
SS0906â
20130109-B
MIL-STD-202
JESD22-B111
JIS-C-6429
AR-001C
J-STD-002
|
Untitled
Abstract: No abstract text available
Text: SPECIFICATION FOR APPROVAL REF. : PROD. NAME SS0805□□□□F□-□□□ ABC'S DWG NO. Shielded SMD Power Inductor REV. 20130104-A PAGE 1 A 101 Ⅰ﹒Configuration and dimensions: Marking Inductance Code C B F D E H D G I I PCB Pattern Unit:m/m
|
Original
|
PDF
|
SS0805â
0130104-A
30sec
MIL-STD-202
JESD22-B111
JIS-C-6429
AR-001C
J-STD-002
|
Untitled
Abstract: No abstract text available
Text: GSP4 Connectors Inlets/Outlets www.schurter.com/PG07 IEC Appliance Inlet C20 or C24, Split panel or screw-on mounting, PCB Terminal Split panel mounting Snap-in PCB Split panel mounting Screw-on PCB C20 C24 70° C 70° C Description - Panel Mount: Splitpanel (sandwich) or screw-on from backside
|
Original
|
PDF
|
com/PG07
VAC19KS
|
Untitled
Abstract: No abstract text available
Text: KP FH Power entry modules without line filter www.schurter.com/PG05 IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole Inlet with fuseholder (5x20 mm) Medical fuse drawer KPF Filter Module (not enclosed) C14 70° C Description - Panel Mount: Sandwich/rear-side
|
Original
|
PDF
|
com/PG05
E93617
0102-G
|
Untitled
Abstract: No abstract text available
Text: KP Switch Power entry modules without line filter www.schurter.com/PG05 IEC Appliance Inlet C14 with Line Switch 1- or 2-pole Inlet with line switch KPF Filter Module (not enclosed) C14 70° C Description - Panel Mount: Sandwich/rear-side - 2 Functions:
|
Original
|
PDF
|
com/PG05
E96454
0102-G
|
Untitled
Abstract: No abstract text available
Text: 6200 Power entry modules without line filter www.schurter.com/PG05 IEC Appliance Inlet C14 with Fuseholder 1-pole Screw-on version Snap-in version C14 70° C Description - Panel Mount: Screw-on version from front or rear side, snap-in version from front side
|
Original
|
PDF
|
com/PG05
E93617
0102-G
|
Untitled
Abstract: No abstract text available
Text: 6220 Power entry modules without line filter www.schurter.com/PG05 IEC Appliance Inlet C14 with Fuseholder 2-pole Screw-On Version Plug removal necessary for fuse replacement Snap-In Version C14 70° C Description - Panel Mount: Screw-on version from front or rear side, snap-in version from front
|
Original
|
PDF
|
com/PG05
0102-G
|
Untitled
Abstract: No abstract text available
Text: DIGITRON SEMICONDUCTORS MCR12LD, MCR12LM, MCR12LN SILICON CONTROLLED RECTIFIERS Available Non-RoHS standard or RoHS compliant (add PBF suffix). Available as “HR” (high reliability) screened per MIL-PRF-19500, JANTX level. Add “HR” suffix to base part number.
|
Original
|
PDF
|
MCR12LD,
MCR12LM,
MCR12LN
MIL-PRF-19500,
MCR12LD
MCR12LM
O-220AB
|
Untitled
Abstract: No abstract text available
Text: TTC3710B バイポーラトランジスタ シリコンNPNエピタキシャル形 TTC3710B 1. 用途 • 大電流スイッチング用 2. 特長 1 コレクタエミッタ間飽和電圧が低い: VCE(sat) = 0.4 V (最大) (IC = 6 A , IB = 0.3 A) (2)
|
Original
|
PDF
|
TTC3710B
TTA1452Bã
O-220SIS
|
Untitled
Abstract: No abstract text available
Text: DIGITRON SEMICONDUCTORS 2N4167-2N4174 SILICON CONTROLLED RECTIFIERS MAXIMUM RATINGS Rating Symbol Peak repetitive forward and reverse blocking voltage 2N4167 2N4168 2N4169 2N4170 2N4172 2N4174 Forward current RMS Value 25 50 100 200 400 600 VDRM, VRRM IT RMS
|
Original
|
PDF
|
2N4167-2N4174
2N4167
2N4168
2N4169
2N4170
2N4172
2N4174
MIL-PRF-19500,
|
Untitled
Abstract: No abstract text available
Text: DIGITRON SEMICONDUCTORS MCR25D, MCR25M, MCR25N SILICON CONTROLLED RECTIFIERS Available Non-RoHS standard or RoHS compliant (add PBF suffix). Available as “HR” (high reliability) screened per MIL-PRF-19500, JANTX level. Add “HR” suffix to base part number.
|
Original
|
PDF
|
MCR25D,
MCR25M,
MCR25N
MIL-PRF-19500,
MCR25D
MCR25M
O-220AB
|
Untitled
Abstract: No abstract text available
Text: DIGITRON SEMICONDUCTORS MCR16N SILICON CONTROLLED RECTIFIERS Available Non-RoHS standard or RoHS compliant (add PBF suffix). Available as “HR” (high reliability) screened per MIL-PRF-19500, JANTX level. Add “HR” suffix to base part number. MAXIMUM RATINGS
|
Original
|
PDF
|
MCR16N
MIL-PRF-19500,
O-220AB
|
Untitled
Abstract: No abstract text available
Text: A Dimensions: [mm] B Recommended land pattern: [mm] D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 100 kHz/ 1 mA L 82 µH ±20% Rated current ∆T = 40 K IR 0.46 A max. Saturation current |ΔL/L| < 35% 0.68 A typ. DC Resistance
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: A Dimensions: [mm] B Recommended land pattern: [mm] D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 100 kHz/ 1 mA L 0.22 µH ±30% Rated current ∆T = 40 K IR 5.00 A max. Saturation current |ΔL/L| < 35% 13.0 A typ. DC Resistance
|
Original
|
PDF
|
|
|
Untitled
Abstract: No abstract text available
Text: A Dimensions: [mm] B Recommended land pattern: [mm] D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 100 kHz/ 1 mA L 22 µH ±20% Rated current ∆T = 40 K IR 0.65 A max. Saturation current |ΔL/L| < 35% 1.10 A typ. DC Resistance
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: A Dimensions: [mm] B Recommended land pattern: [mm] D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 100 kHz/ 1 mA L 0.82 µH ±20% Rated current ∆T = 40 K IR 3.40 A max. Saturation current |ΔL/L| < 35% 7.10 A typ. DC Resistance
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: A Dimensions: [mm] B Recommended land pattern: [mm] D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 100 kHz/ 1 mA L 8.2 µH ±20% Rated current ∆T = 40 K IR 1.75 A max. Saturation current |ΔL/L| < 35% 2.20 A typ. DC Resistance
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: A Dimensions: [mm] B Recommended land pattern: [mm] D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 100 kHz/ 1 mA L 8.2 µH ±20% Rated current ∆T = 40 K IR 1.40 A max. Saturation current |ΔL/L| < 35% 2.20 A typ. DC Resistance
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: A Dimensions: [mm] B Recommended land pattern: [mm] D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 100 kHz/ 1 mA L 2.2 µH ±20% Rated current ∆T = 40 K IR 2.10 A max. Saturation current |ΔL/L| < 35% 3.60 A typ. DC Resistance
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: KEB1 Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Inlet C14 with Line Switch 1-pole C14 70° C Description Characteristics - Panel Mount: Screw-on version from front or rear side, snap-in version from front side - 2 Functions:
|
Original
|
PDF
|
com/pg05
E96454
0102-G
|
Untitled
Abstract: No abstract text available
Text: GSP4 Connectors Inlets/Outlets www.schurter.com/PG07 IEC Appliance Inlet C20 or C24, Split panel or screw-on mounting, PCB Terminal Split panel mounting Snap-in PCB Split panel mounting Screw-on PCB C20 C24 70° C 70° C Screw-on panel mounting Snap-in PCB
|
Original
|
PDF
|
com/PG07
VAC19KS
|
Untitled
Abstract: No abstract text available
Text: 8843.ZP30 Connectors Inlets/Outlets www.schurter.com/PG07 IEC Appliance Inlet C14, Screw-on Mounting, Front Side, PCB Terminal C14 70° C Description Other versions on request - Panel Mount: Screw-on mounting on PCB from front side - 1 Function: Appliance Inlet, Pin temperature 70 °C, Protection class I
|
Original
|
PDF
|
com/PG07
0102-G
|
Untitled
Abstract: No abstract text available
Text: 8843.ZP30 Connectors Inlets/Outlets www.schurter.com/PG07 IEC Appliance Inlet C14, Screw-on Mounting, Front Side, Solder Terminal C14 70° C Description Weblinks - Panel Mount: Screw-on mounting on PCB from front side - 1 Function: - Appliance Inlet, Pin temperature 70 °C, Protection class I
|
Original
|
PDF
|
com/PG07
E96454
|
Untitled
Abstract: No abstract text available
Text: KP Switch Power entry modules without line filter www.schurter.com/PG05 IEC Appliance Inlet C14 with Line Switch 1- or 2-pole Inlet with line switch KPF Filter Module (not enclosed) C14 70° C Description Characteristics - Panel Mount: Sandwich/rear-side
|
Original
|
PDF
|
com/PG05
0102-G
|