220v AC to 110v AC circuit diagram
Abstract: IEC414 magnetic transducers ud 99 AC110V DIN46277 IEC688
Text: S3 SERIES S3-PD, S3-UD POWER FACTOR, PHASE ANGLE TRANSDUCER FEATURES Accuracy 0.5% RO. PD , 1 (UD) Excellent long term stability (4~20mA, 500 ) Precision measurement even for distorted wave High impulse & surge protection(5KV) The case can be mounted on a 35mm rail which complies with DIN46277
|
Original
|
DIN46277
90V/110V
08V/120V)
80V/220V
16V/240V)
AC220V
220v AC to 110v AC circuit diagram
IEC414
magnetic transducers
ud 99
AC110V
DIN46277
IEC688
|
PDF
|
nais relay
Abstract: nais relays hp SP2-DC24V SP2-L2-DC24V SP4-L2-DC24V 202C10 Nais latching relays nais 68 TIP 126 LR26550
Text: SP 15A 2C , 10A (4C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY UL File No.: E43028 CSA File No.: LR26550 a 50 1.969 • High Vibration/Shock Resistance Vibration resistance: 18 G, amplitude 3 mm (10 to 55 Hz) Shock resistance: 40 G (11 ms) • Latching types available
|
Original
|
E43028
LR26550
nais relay
nais relays hp
SP2-DC24V
SP2-L2-DC24V
SP4-L2-DC24V
202C10
Nais latching relays
nais 68
TIP 126
LR26550
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SF SLIM COMPACT SAFETY RELAY SF-RELAYS Slim type FEATURES Max. 13 .512 Max. 40 1.575 Max. 24 .945 mm inch RoHS Directive compatibility information http://www.nais-e.com/ • Forced guide contact structure EN50205 ClassA TÜV recognized • Slim profile (mm inch)
|
Original
|
EN50205
|
PDF
|
NAIS Relay s2 - 24v
Abstract: nais relay cross reference Nais Relay s2 12v nais relay 12v 10a three relay stabilizer circuit diagram nais relay tq nais RELAY s2 24v Relay NAIS tq SCR TRIGGER PULSE TRANSFORMER 4503 Nais S2 -12V RELAY
Text: SP 15A 2C , 10A (4C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY UL File No.: E43028 CSA File No.: LR26550 a 50 1.969 • High Vibration/Shock Resistance Vibration resistance: 18 G, amplitude 3 mm (10 to 55 Hz) Shock resistance: 40 G (11 ms) • Latching types available
|
Original
|
E43028
LR26550
NAIS Relay s2 - 24v
nais relay cross reference
Nais Relay s2 12v
nais relay 12v 10a
three relay stabilizer circuit diagram
nais relay tq
nais RELAY s2 24v
Relay NAIS tq
SCR TRIGGER PULSE TRANSFORMER 4503
Nais S2 -12V RELAY
|
PDF
|
rtc ds130
Abstract: No abstract text available
Text: Surge Protection AC & DC Power Photovoltaic Telecom Dataline Coaxial SURGE PROTECTORS for AC & DC Power, Photovoltaic, Telecom, Dataline, & Coaxial - 9 t h e d i t i o n , N o r t h A m e r i c a 9 th E d i t i o n North America 1 9 th E d i t i o n North America
|
Original
|
RU-105082
rtc ds130
|
PDF
|
luminous inverter circuit diagram for repairing
Abstract: citel 08 90v
Text: 9 th e d i t i o n Surge Protection Electrical Installations Photovoltaic Telecom Data Radiocommunication General Catalog 9th edition p. 6 DIN RAIL AC POWER SURGE PROTECTORS p. 60 p. 70 AC POWER SURGE PROTECTORS p. 78 p. 94 HIGH FREQUENCY COAXIAL SURGE PROTECTORS
|
Original
|
RU-105082
FL33025
luminous inverter circuit diagram for repairing
citel 08 90v
|
PDF
|
SFS3-L-DC24V
Abstract: DIN terminal socket Of SFS2-DC24V SFS2-L-DC24V ups PURE SINE WAVE schematic diagram SFS2-DC24V SFS3-DC24V SFS4-DC12V SFS4-DC24V
Text: SFS SLIM COMPACT SAFETY RELAY SF RELAYS Slim type FEATURES RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/ 1. Forcibly guided contact structure EN50205 ClassA TÜV recognized 2. Slim profile (mm inch) Compact size with slim profile relay
|
Original
|
EN50205
200gher
SFS3-L-DC24V
DIN terminal socket Of SFS2-DC24V
SFS2-L-DC24V
ups PURE SINE WAVE schematic diagram
SFS2-DC24V
SFS3-DC24V
SFS4-DC12V
SFS4-DC24V
|
PDF
|
DIN46277-1
Abstract: electrical house wiring Ellison Sensors International DIN43650 PR3000 pressure circuit diagram Pressure transmitter 4 WIRE
Text: PROTRAN PR3000 DIN RAIL MOUNTED PRESSURE TRANSMITTER HIGH STABILITY CERAMIC SENSOR SUPPLY VOLTAGE 13 - 36Vdc 4-20mA TWO-WIRE OUTPUT ZERO + SPAN ADJUSTMENT ON-SITE RANGES 500mbar to 400bar DIN RAIL MOUNTABLE DIN 46277-1 PROTECTED TO IP65 INTRINSICALLY SAFE MODELS
|
Original
|
PR3000
36Vdc
4-20mA
500mbar
400bar
0-10bar
PR3000
DIN46277-1
electrical house wiring
Ellison Sensors International
DIN43650
pressure circuit diagram
Pressure transmitter 4 WIRE
|
PDF
|
nais relays
Abstract: nais relay S2 nais relay nais sp2 matsushita relay sp4 SP4-DC24V SP4-DC48V SP4-L2-DC24V DC24V SP2-DC24V
Text: 15A 2C , 10A (4C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY FEATURES a 50 1.969 SP RELAYS • High Vibration/Shock Resistance Vibration resistance: 18 G, amplitude 3 mm (10 to 55 Hz) Shock resistance: 40 G (11 ms) • Latching types available • High Sensitivity in Small Size 150 mW pick-up, 300 mW
|
Original
|
|
PDF
|
SP2-DC12V
Abstract: SP2-DC24V SP2-DC48V SP2-L2-DC12V SP2-L2-DC24V SP2-L2-DC48V SP4-DC12V SP4-DC24V SP4-DC48V
Text: SP 15A 2 Form C , 10A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY SP RELAYS FEATURES Taking advantage of the 4-gap balanced armature mechanism, S relays have met a number of relay needs and earned a reputation for the characteristics that they provide. Building on the same structure,
|
Original
|
DIN46277)
300108D
SP2-DC12V
SP2-DC24V
SP2-DC48V
SP2-L2-DC12V
SP2-L2-DC24V
SP2-L2-DC48V
SP4-DC12V
SP4-DC24V
SP4-DC48V
|
PDF
|
HC2K-DC48V-F
Abstract: relay magnetic HC2K-AC100V-F Panasonic RELAY Cross Reference HC2K-DC24V-F HC2K-AC24V-F HC2K-DC24V HC2K-AC24V HC2-SS-K HC2K-DC100V-F
Text: HC LATCHING KEEP HC LATCHING (KEEP) RELAYS MAGNETIC MEMORY TYPE HC RELAY FEATURES About Cd-free contacts We have introduced Cadmium free type products to reduce Environmental Hazardous Substances. (The suffix “F” should be added to the part number.)
|
Original
|
25Y-3N,
25Y-3S
25-3X,
1071-A
25-3S
25-3TA
25-M3
HC2K-DC48V-F
relay magnetic
HC2K-AC100V-F
Panasonic RELAY Cross Reference
HC2K-DC24V-F
HC2K-AC24V-F
HC2K-DC24V
HC2K-AC24V
HC2-SS-K
HC2K-DC100V-F
|
PDF
|
hc4-dc12v
Abstract: HC4-DC24V HC2-DC24V HC2-SS-K HC3-DC24V HC3-DC6V-D-F nichifu HC4-DC24V-D HC1-DC12V HC2-L-DC24V-D-F
Text: HC Has built-in diode to absorb surge For use in semiconductor circuits HC RELAY WITH DIODE TYPE FOR DC FEATURES 1. The built-in diode absorbs surge voltage arising when the coil goes to the off state (for DC type). Diode characteristics; Reverse breakdown voltage: 1,000V,
|
Original
|
25Y-3N,
25Y-3S
25-3X,
1071-A
25-3S
25-3TA
25-M3
hc4-dc12v
HC4-DC24V
HC2-DC24V
HC2-SS-K
HC3-DC24V
HC3-DC6V-D-F
nichifu
HC4-DC24V-D
HC1-DC12V
HC2-L-DC24V-D-F
|
PDF
|
HC2-SS-K
Abstract: HC4-SFD-K hc2-ac100v-r-f
Text: HC Able to absorb surge voltage in AC specification CR circuit is built-in HC RELAYS WITH CR CIRCUIT FEATURES 1. With CR circuits built in, surge voltage arising in the AC type when the coil goes to the off state is absorbed. 2. HC relay with LED indication type
|
Original
|
25Y-3N,
25Y-3S
25-3X,
1071-A
25-3S
25-3TA
25-M3
HC2-SS-K
HC4-SFD-K
hc2-ac100v-r-f
|
PDF
|
mitsubishi plc FX SERIES
Abstract: cable diagram mitsubishi plc FX2N SERIES mitsubishi plc FX2N SERIES Mitsubishi PLC Communication Cable mac 50 JY992D88101 mitsubishi plc FX1s wiring diagrams fx2n manual FX2N-64DNET fx2n mitsubishi plc cable fx series
Text: USER’S MANUAL FX2N-64DNET DeviceNet Interface Block FX2N-64DNET DeviceNet Interface Block Foreword • This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-64DNET DeviceNet Interface Block. It should be read and understood befre attempting
|
Original
|
FX2N-64DNET
JY992D48301
JY992D88101
J24532
JY992D86301A
mitsubishi plc FX SERIES
cable diagram mitsubishi plc FX2N SERIES
mitsubishi plc FX2N SERIES
Mitsubishi PLC Communication Cable mac 50
mitsubishi plc FX1s wiring diagrams
fx2n manual
fx2n
mitsubishi plc cable fx series
|
PDF
|
|
LEM Components
Abstract: DC24 DIN46277
Text: 电量传感器 VBT450-NND1D7 用于测量交流电压 原 VPN = 450V 副边之间高度绝缘 电参数 vPN vP ISN 原边额定电压 原边电压测量范围 副边输出电流 Va IC Vd 辅助电源 电流消耗 直流电压耐压测试 , 1 min 450 120 当Ip=0: Is=4
|
Original
|
VBT450-NND1D7
00A/m
94-V0
DIN46277
160ppm
VBT450-NND1D7
LEM Components
DC24
|
PDF
|
DIN46277-3
Abstract: ttl 4511 61000-6-2 74 4511 IEC 61000-4-3 UL-508C ip 20, IEC 529
Text: Industrial Power Supplies TTL Series 480 Watt Features Pending 3-Phase Universal Input 360–575VAC, 50/60Hz Pending Easy snap-on mounting on DIN-Rails Output Voltage adjustable Power Good Signal Low Output Ripple and Noise High Efficiency Overload Protection
|
Original
|
575VAC,
50/60Hz
EN55011,
DIN46277-3
CH-8002
DIN46277-3
ttl 4511
61000-6-2
74 4511
IEC 61000-4-3
UL-508C
ip 20, IEC 529
|
PDF
|
BLYT10-NND1D7
Abstract: DIN46277 DC24
Text: 电 量 传 感 器 BLYT-NND1D7系 列 用于测量交流电流 原 IPN = 5A , 10A 副边之间高度绝缘 电参数 IPN IP ISN 原边额定电流 原边电流测量范围 副边输出电流 VC IC Vd 辅助电源 电流消耗 电压耐压测试 50Hz, 1 min
|
Original
|
BLYT10-NND1D7
EN50178
94-V0
DIN46277
DIN35mm
BLYT10-NND1D7
DC24
|
PDF
|
FX2N-8AD
Abstract: mitsubishi plc FX2N SERIES mitsubishi plc FX1s wiring diagrams FX2N HARDWARE MANUAL Mitsubishi FX1N JY992D88201 Hardware manual JY992D88101 Mitsubishi PLC FX1S user manual K2050 FX programming manual mitsubishi plc FX1s SERIES cable
Text: USER’S MANUAL FX2N-8AD Analog input block FX2N-8AD Analog input block Foreword • This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-8AD Analog input block. It should be read and understood before attempting to
|
Original
|
JY992D48301
JY992D88101
J24532
JY992D86001A
MEE0005)
FX2N-8AD
mitsubishi plc FX2N SERIES
mitsubishi plc FX1s wiring diagrams
FX2N HARDWARE MANUAL
Mitsubishi FX1N JY992D88201 Hardware manual
Mitsubishi PLC FX1S user manual
K2050
FX programming manual
mitsubishi plc FX1s SERIES cable
|
PDF
|
essailec
Abstract: 1SNA892461R1500 entrelec diode XUS001735 1SNA XUS001738 367-17 SNBT23 0165 830.21 n0190
Text: Short Form Catalog Terminal blocks Terminal blocks Product index Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 0. Table of contents and alphanumeric listing 1. Screw clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 - 37
|
Original
|
C0201
essailec
1SNA892461R1500
entrelec diode
XUS001735
1SNA
XUS001738
367-17
SNBT23
0165 830.21
n0190
|
PDF
|
MTL5544D
Abstract: MTL5575 MTL5516 MTL5546Y MTL5504 MTL5517 MTL5541S MTL5532
Text: MTL5500 Series isolating interface units Instruction Manual INM5500 ii INM5500-4 October 2013 Contents 1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
|
Original
|
MTL5500
INM5500
INM5500-4
MTL5544D
MTL5575
MTL5516
MTL5546Y
MTL5504
MTL5517
MTL5541S
MTL5532
|
PDF
|
pdx matsua
Abstract: pdx matsushita Hc2 matsua 110v relay cross reference MATSUA HC4ED-H-DC24V MATSUA HC4 HC2E-H-AC100V-F relay dc 24V matsua 5A 8 pole relay 220v ac HC1E-HTM-AC12V-F HC4ED-H-AC24V
Text: HC Plug-in type PC board type TM type SEALED CONSTRUCTION High reliability ensured in challenging environments. HC RELAYS AMBER SEALED TYPE FEATURES TYPICAL APPLICATIONS 1. Even when left for long periods in challenging environments, resistance values for the contacts remain stable.
|
Original
|
25Y-3N,
25Y-3S
25-3X,
1071-A
25-3S
25-3TA
25-M3
pdx matsua
pdx matsushita
Hc2 matsua 110v
relay cross reference MATSUA HC4ED-H-DC24V
MATSUA HC4
HC2E-H-AC100V-F
relay dc 24V matsua
5A 8 pole relay 220v ac
HC1E-HTM-AC12V-F
HC4ED-H-AC24V
|
PDF
|
matsua relay sp4
Abstract: nais relay SP4-DC12V nais relay DC24V
Text: SP 15A 2C , 10A (4C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY FEATURES a 50 1.969 SP RELAYS 22 .866 mm inch 2C 4C a 25.6 1.008 36.8 1.449 • High Vibration/Shock Resistance Vibration resistance: 18 G, amplitude 3 mm (10 to 55 Hz) Shock resistance: 40 G (11 ms)
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SP 15A 2 Form C , 10A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY SP RELAYS FEATURES Taking advantage of the 4-gap balanced armature mechanism, S relays have met a number of relay needs and earned a reputation for the characteristics that they provide. Building on the same structure,
|
Original
|
DIN46277)
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Disconnect Terminal Blocks Type WK10/TK32 10 mm2 95 W ire Size fin e S tra n d e d 1-10 S tra n d e d 10-16 C SA 6 0 0V 6 AW G 27A UL 6 0 0V 6 -1 6 AW G 27 A I III A p p ro v a ls w id th /w ire s trip le n g th w id th 12mm w ire s trip le n g th 9mm Materials
|
OCR Scan
|
WK10/TK32
WK10/TK32
9008U
10/Si
10/Si-4_
10/Si-5_
10/Si-6
|
PDF
|