Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    A0021E Search Results

    SF Impression Pixel

    A0021E Price and Stock

    Advantech Co Ltd AMK-A0021E

    Solid State Drives - SSD
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Mouser Electronics AMK-A0021E
    • 1 $154.58
    • 10 $154.58
    • 100 $154.58
    • 1000 $154.58
    • 10000 $154.58
    Get Quote

    A0021E Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    PJ-3057-P

    Abstract: Battery 006P 006P C6080 C6080-02 C6080-03
    Text: UV POWER METERS C6080 SERIES A Wide Lineup of 248 nm, 365 nm and 436 nm Type The C6080 series is a compact UV power meter specifically designed to measure the intensity of UV radiation emitted from the light guide output end of a UV spot light source. The C6080


    Original
    C6080 C6080 G200-hours SE-171-41 1005E06 PJ-3057-P Battery 006P 006P C6080-02 C6080-03 PDF

    g-sensor

    Abstract: UV diode 365 nm IC6080-02 E8718-02 uv sensor 006P C6080 C6080-02 C6080-03 C6080-13
    Text: UV POWER METERS C6080 SERIES A Wide Lineup of 248 nm, 365 nm and 436 nm Type The C6080 series is a compact UV power meter specifically designed to measure the intensity of UV radiation emitted from the light guide output end of a UV spot light source. The C6080


    Original
    C6080 C6080 G200-hours SE-171-41 1005E07 g-sensor UV diode 365 nm IC6080-02 E8718-02 uv sensor 006P C6080-02 C6080-03 C6080-13 PDF

    R8811

    Abstract: R8810
    Text: PRELIMINARY Specifications Parameter R8810 Gain Typ. 2x Dark Current (Typ.) Operating Pressure Level (Max.) 103 R8811 (at -1000 V) 1x 105 (at -1500 V) 3 x 10-14 A (at -1000 V) 3 x 10-14 A (at -1500 V) 1 Pa * 1 x 10-2 Pa 350 °C Bake-Out Temperature (at 10-4 Pa, Max.)


    Original
    R8810 R8811 R8810 B0061EA B0036EA R8811 PDF

    R5150

    Abstract: R5150-90
    Text: PRELIMINARY Compact Ion Detectors R5150-50, -90 Detection Efficiency vs. Input Ion Energy Structure R5150-90 GND Q-POLE FARADAY-CUP The electron lens created by the Faraday cup, the ion deflection electrodes and the electron multiplier electrodes maintains high detection efficiency even when input ion energy increases.


    Original
    R5150-50, R5150-90 R5150- B0059EA SE-171-41 R5150 R5150-90 PDF

    Untitled

    Abstract: No abstract text available
    Text: ELECTRON MULTIPLIER R8811 For Compact Mass Spectrometers OVERVIEW Quadrupole mass spectrometers used for residual gas analyzers have been downsized to solve problems of limited installation space. A trend of the downsizing would be an ever-greater degree in the future. However, it cannot be achieved just by reducing the ion source and Quadrupole electrode sizes. Small ion


    Original
    R8811 SE-164 TPMH1340E02 B1201 PDF