y 803
Abstract: No abstract text available
Text: Series 803 “Mighty Mouse” Bayonet Connectors Normal and Alternate Key Positions Series 803 Links Series 803 Series 803 Bayonet Connectors are available in four keying positions: N — Normal X — Alternate Key #1 Y — Alternate Key #2 Z — Alternate Key #3
|
Original
|
818-te
y 803
|
PDF
|
mighty mouse
Abstract: No abstract text available
Text: Series 80 Mighty Mouse Series 80 “Mighty Mouse” Filter Connector Normal and Alternate Key Positions and Panel Cut-Out Dimensions A — Normal Keying B — Alternate #1 C — Alternate #2 Plug Key Positions Receptacle Key Positions A° B°
|
Original
|
|
PDF
|
Normal and Alternate Key Positions
Abstract: Filter Connectors
Text: Filter Connectors Series 80 Mighty Mouse Filter Connector Normal and Alternate Key Positions SERIES Plug Key Positions Receptacle Keyway Positions 801 804 805 A° A° B° B° Series 80 Mighty Mouse Alternate Key Positions Key Position Notes A° B° A Normal
|
Original
|
|
PDF
|
alternate key positions
Abstract: No abstract text available
Text: MIL-DTL-5015 Type MIL-DTL-5015 Type Hermetic Power and Signal Connectors Alternate Key Positions Alternate Key Positions Alternate Key Positions Dash Number W° X° Y° Z° Dash Number W° X° Y° Z° 8S-1 – – – – 20-22 80 110 250 280 10S-2 – –
|
Original
|
MIL-DTL-5015
MIL-DTL-5015
10S-2
10SL-3
10SL-4
12S-3
12S-4
14S-1
alternate key positions
|
PDF
|
14S-5
Abstract: 14S-7 14S-6
Text: MIL-DTL 5015 Type MIL-DTL-5015 Type Hermetic Power and Signal Connectors Alternate Key Positions Alternate Key Positions Alternate Key Positions Dash Number W° X° Y° Z° Dash Number W° X° Y° Z° 8S-1 – – – – 20-22 80 110 250 280 10S-2 – –
|
Original
|
MIL-DTL-5015
10S-2
10SL-3
10SL-4
12S-3
12S-4
14S-1
14S-2
14S-5
14S-7
14S-6
|
PDF
|
Normal and Alternate Key Positions
Abstract: No abstract text available
Text: Mighty Mouse Series 80 Mighty Mouse Filter Connector Normal and Alternate Key Positions SERIES Plug Key Positions Receptacle Keyway Positions 801 804 805 C A° A° B° B° Series 80 Mighty Mouse Alternate Key Positions Key Notes A° Position B° A Normal 150°
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Amphenol Aerospace MIL-DTL-83723, Series III, Matrix Insert Availability and Identification, Alternate Keying Positions, Alternate Rotations INSERT ARRANGEMENTS ALTERNATE KEYING POSITIONS Rotation of key/keyway of shell Contact Size To avoid cross-plugging problems in
|
Original
|
MIL-DTL-83723,
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Miniature Cylindrical MIL-C-83723, Series III alternate positioning ALTERNATE KEYING POSITIONS Rotation of key/keyway of shell ALTERNATE CLOCKING POSITIONS (Rotation of insert) To avoid cross-plugging problems in applications requiring the use of more than one connector of the same size and arrangement, alternate keying positions are available as indicated in the
|
Original
|
MIL-C-83723,
alter15
MIL-STD-1554.
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Series 801 “Mighty Mouse” Double-Start Receptacle Connectors Normal and Alternate Key Positions Series 801 Links Series 801 Double-Start Plugs and Receptacles feature a Master Key and two Secondary Keys for positive mating. Four key positions are available:
|
Original
|
|
PDF
|
VDE0660
Abstract: Airpax 5003 Z151 288-1315-ND Airpax Z15-20 Z1533-ND A22S-3M-20 Airpax motor A22S-2M
Text: A22 Series Switches Cont. Key Type Selector Switches Key Selector switches for secured switching or resetting. Available in either momentary or Alternate Action. (IP65 oil and dust tight construction.) Comes complete with 2 keys. Contact: 10A@110VAC or 24VDC
|
Original
|
110VAC
24VDC
288-1339-ND
288-1329-ND
288-1330-ND
288-1340-ND
288-1341-ND
288-1342-ND
288-1331-ND
288-1337-ND
VDE0660
Airpax 5003
Z151
288-1315-ND
Airpax
Z15-20
Z1533-ND
A22S-3M-20
Airpax motor
A22S-2M
|
PDF
|
Alternate Keying Positions
Abstract: No abstract text available
Text: SERIES 23 Filter connectors Alternate keying positions MIL-DTL-38999 Series III type PLUG RECEPTACLE MASTER KEY MASTER KEYWAY W° W° Z° Z° X° X° Y° Y° NOTE: ALL MINOR KEYS AND KEYWAYS ARE ROTATED TO PROVIDE POLARIZATION WHILE MASTER KEY AND KEYWAY REMAIN FIXED.
|
Original
|
MIL-DTL-38999
Alternate Keying Positions
|
PDF
|
patt 602
Abstract: SAV-CON
Text: Sav-Con Connector Savers PATT 105 - PATT 602 Sav-Con® Connector Savers 94 0 L 009 N 24 G 61 P AA-B 131 Modification Codes* Omit for None Alternate Position A,B,C,D,E,F (N = Normal) Alternate Key Configuration AA, BB, CC, DD P = Pins, Plug Side S = Sockets, Plug Side
|
Original
|
|
PDF
|
m2-v hydraulic fluid
Abstract: AE833 MS3186 m85049 instructions AE83384
Text: MIL-DTL-83723 Series III Features and Application Bayonet and Threaded Coupling Features and Application Shell Polarization – Alternate key/keyway positions prevent cross mating of adjacent connectors having same insert arrangement. MIL-DTL-83723 Series III family offers connectors with
|
Original
|
MIL-DTL-83723
MIL-DTL-26500
AE833
MIL-STD-1554
m2-v hydraulic fluid
MS3186
m85049 instructions
AE83384
|
PDF
|
MS27488-20-1
Abstract: M81969/14-11 MIL-PRF-7808 MS27488-16-1 m39029/5-115 m39029/4-110 m39029/5-118 M22520/2-02 MS27488-16 M22520/1-02
Text: MIL-DTL-83723 Series III Features and Application Bayonet and Threaded Coupling Features and Application Shell Polarization – Alternate key/keyway positions prevent cross mating of adjacent connectors having same insert arrangement. MIL-DTL-83723 Series III family offers connectors with
|
Original
|
MIL-DTL-83723
MIL-DTL-26500
MIL-STD-1554
MIL-STD-1554
MS27488-20-1
M81969/14-11
MIL-PRF-7808
MS27488-16-1
m39029/5-115
m39029/4-110
m39029/5-118
M22520/2-02
MS27488-16
M22520/1-02
|
PDF
|
|
multimod
Abstract: harness assembly
Text: Make 120 Connector Combinations from Only 12 Components With Glenair’s “Plug and Play” Multi-Mod Connector Bayonet Coupling Plug 5 Alternate Color-Coded Key Positions Pins or Sockets in Plug or Receptacle SPECIFICATIONS Voltage: 400 VAC Sea Level 550 VDC Sea Level
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: CD00272690 Rev 1.1 IN APPROVAL PAGE A ft 15 Watt regulated Triac-dimmable LED driver for the North American 115 V market -D ra Technical Literature Alternate Identifier(s) Key process 17474 Product Development Dr ISO Definition aft CUSTOM ATTRIBUTES ft -
|
Original
|
CD00272690
STEVAL-ILL016V2,
|
PDF
|
Mighty Mouse to AlphaLink Flex Jumpers
Abstract: No abstract text available
Text: mighty mouse to alphalink flex jumpers Contact arrangements • dimensions • alternate key positions Mighty Mouse to AlphaLink Flex Jumpers Glenair Series 801 double-start ACME thread and Series 804 quick-disconnect Mighty Mouse receptacles in 8 contact arrangements terminated with rugged polyimide-based flex to highperformance AlphaLink SL board level connectors.
|
Original
|
|
PDF
|
GC443
Abstract: No abstract text available
Text: Sav-Con connector savers MIL-DTL-38999 Series I GC443 In-Line Bayonet Coupling Gender Changer HOW TO ORDER Sample Part Number GC443 Series GC443 Style A - In-line Finish See Table I Shell Size See Table II Alternate Key Position A, B, C, D, Omit for Normal; See Table III
|
Original
|
MIL-DTL-38999
GC443
GC443
MIL-C-38999
|
PDF
|
0 280 130 122
Abstract: 32A48 32-B22 40A21 32-A48 stegmann+AG+110 GMPM2-B112RCBSXU.110
Text: Insert Rotations Alternate Positions Alternate Positions of Insert Arrangements KEY STATIONARY - INSERT ROTATED Front View of Pin Insert INSERT DEGREES FOR ALTERNATE POSITIONS TYPE W X Y Z 14S-2 14S-5 14S-6 14S-7 14S-9 16S-1 16S-4 16S-5 Insert Rotations Alternate Positions
|
OCR Scan
|
14S-2
14S-5
14S-6
14S-7
14S-9
16S-1
16S-4
16S-5
16S-8
6A-10
0 280 130 122
32A48
32-B22
40A21
32-A48
stegmann+AG+110
GMPM2-B112RCBSXU.110
|
PDF
|
B4750
Abstract: No abstract text available
Text: m o l e x " Circular Industriar Connectors Spirit In field insert keying is achieved by alignment of a molded key Front Shell Assembly letter on the rear of the insert with an indicator on the rear of the shell during assembly. Eight alternate keying positions are
|
OCR Scan
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MIL-C-26482 SERIES II POLARIZING POSITIONS t The normal position N has the insert centerline coinciding with the centerline of the master key (or keyway) of the shell. The alternate clocking positions (W,X,Y, and Z) are accom plished by rotating the pin insert clockwise. The socket insert
|
OCR Scan
|
MIL-C-26482
AE770*
AE772*
AE774*
MS3470*
MS3471*
MS3472*
MS3474*
AE775*
|
PDF
|
Untitled
Abstract: No abstract text available
Text: /T V m o l e x Circular Industrial Connectors Spirit™ In field insert keying is achieved by alignment of a molded key letter on the rear of the insert with an indicator on the rear of Front Shell Assembly the shell during assembly. Eight alternate keying positions are
|
OCR Scan
|
606I-T6
36203M03
36103M03
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MIL-C-83723 III AERO ELECTRIC MIL-C-83723 SERIES III POLARIZING LOCKSMITH KEYED POSITIONS MACHINED IN THE SHELL In the normal position (N) the centerline of the insert is the same as the master key or keyway of the shell. In the alternate positions (6,7,8,9, and Y) the minor keys, or
|
OCR Scan
|
MIL-C-83723
POSITI20Â
|
PDF
|
Untitled
Abstract: No abstract text available
Text: c=iP MIL-C-26500 1 = ^ 1 / — r AERO ELECTRIC MIL-C-26500 POLARIZING LOCKSMITH KEYED POSITIONS (MACHINED IN THE SHELL In the normal position (N) the centerline of the insert is the same as the master key or keyway of the shell. In the alternate positions (6,7,8,9, and Y) the minor keys, or
|
OCR Scan
|
MIL-C-26500
MIL-C-26500
|
PDF
|