408-8040
Abstract: AMP 565435-5 crimper
Text: 7 D R A W IN G MADE IN T H IR D PART NUMBER ANGLE 1385731 P R O J E C T IO N REV R IR S T USED 1385731 TERMINAL M AC H IN E 1385731 - 1 1385731-2 A 122500-1 A 565435-5 1385731-3 A 354500-1 r e f GUARD AMP ; NAME: MOLEX PN CUST 1572397-5 1572397-6 1572397-7
|
OCR Scan
|
22MAR201Q
15MAR
JUN04
408-8040
AMP 565435-5 crimper
|
PDF
|
amp 408-9938
Abstract: H314 114-13105 455830-1 E2003 408-7424 565435-5 567067-3
Text: Application Specification 114–13105 Miniature Circular Plastic Connector CPC NOTE 16 SEP 03 Rev O All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
114-13089
Abstract: amp hdi applicator 567067-1 567067-3 114-13105 455830-1 408-9640 E2003 H314 408-7347
Text: Application Specification 114–13105 Miniature Circular Plastic Connector CPC NOTE 16 SEP 03 Rev O All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
AMPOMATOR CLS IV
Abstract: amp 114-1016 408-8040 408-9640 MINIAPPLICATOR bellmouth standard
Text: Application Specification 114-1016 Miniature AMP-IN* Contacts NOTE i 01 JUL 08 Rev W All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
466779
Abstract: 408-6976 Tyco AMP document 408-6976 58080-3 Tyco faston insulated proper hand crimping procedure 408-9902 B 722 P UL-310 Tyco (AMP) document 408-6976 AMP crimper 69710-1 408-2095
Text: Application Specification Ultra- Fast Series 110, 125, 187, 205, and 250 Fully- Insulated FASTON* Terminals NOTE i 114- 2123 02 OCT 09 Rev F All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and
|
Original
|
|
PDF
|
AMP crimper
Abstract: 408-8040 general maintenance for applicators tyco crimp height specification 408-9640 90222-6 408-7974 Tyco 408-8059 354500-1 general list of contact crimp height
Text: Application Specification 114-16003 FFC Round Wire Pin and Receptacle Contacts NOTE i 16 MAY 08 Rev E All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
splice conductors
Abstract: No abstract text available
Text: Application Specification 114-2147 Nylon Closed End Splices NOTE i 09 SEP 08 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
maintenance manual 565435-5
Abstract: machine maintenance checklist 466422-2 hand tools 91503-1 91549-1 instruction maintenance manual 354500-1 408-9404 HD-20 91503-1 91549-1
Text: Application Specification 114-10000 HD-20 Precision Formed Contacts NOTE i 09 FEB 09 Rev T All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
HD-20
maintenance manual 565435-5
machine maintenance checklist
466422-2
hand tools 91503-1
91549-1 instruction
maintenance manual 354500-1
408-9404
91503-1
91549-1
|
PDF
|
tyco crimp height chart
Abstract: 408-7424 59824-1 solder crimp height faston crimp height general maintenance for applicators 58433-3 408-9640 59824-1 Tyco Amp 7432 Tyco 408-7424
Text: Application Specification 114-13076 PIDG* FASTON* Tabs and Fully-Insulated Receptacles NOTE 09 JAN 08 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and _ inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
AMP 59974-1 crimper
Abstract: AMP crimper 69015 AMP 59170 46121 crimping tool 59974-1 AMP crimper 59250 AMP 59250 AMP 59239-4 crimper pneumatic tetra AMP crimper 59170
Text: Application Specification 114- 2161 PLASTI- GRIP* Terminals and Splices NOTE i 03 MAY 11 Rev F All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
|
Original
|
|
PDF
|
AMP 59974-1 crimper
Abstract: 59974-1 AMP crimper 59250 AMP 59170 567200-2 AMP 47387 crimper instruction sheet 408-6765 47387 AMP 59250 69051
Text: Application Specification PLASTI- GRIP* Terminals and Splices NOTE i 114- 2161 31 JUL 09 Rev E All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
|
Original
|
22ATION
AMP 59974-1 crimper
59974-1
AMP crimper 59250
AMP 59170
567200-2
AMP 47387 crimper
instruction sheet 408-6765
47387
AMP 59250
69051
|
PDF
|
69120-1
Abstract: No abstract text available
Text: Application Specification 114-2162 STRATO-THERM* Terminals, Splices, and Spare Wire Caps NOTE 19 NOV 08 All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and Rev C _ inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|