Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    BREAKING CAPACITY Search Results

    BREAKING CAPACITY Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TPS2300IPW Texas Instruments 3-13V Dual HotSwap IC w/ Independent Channel Circuit Breaking & Power Good Report, Act-Low Enable 20-TSSOP -40 to 85 Visit Texas Instruments Buy
    TPS2310IPW Texas Instruments 3-13V Dual HotSwap IC w/ Inter-dependent Channel Circuit Breaking & Pwr Good Report, Act-Low Enable 20-TSSOP -40 to 85 Visit Texas Instruments Buy
    TPS2320IDR Texas Instruments 3-13V Dual Hot-Swap IC w/ Independent Channel Circuit Breaking, Act-Low Enable 16-SOIC -40 to 85 Visit Texas Instruments Buy
    TPS2321IPW Texas Instruments 3-13V Dual Hot-Swap IC w/ Independent Channel Circuit Breaking, Act-High Enable 16-TSSOP -40 to 85 Visit Texas Instruments Buy
    TPS25944ARVCR Texas Instruments 18V, 5A, 42mΩ Circuit Breaking Power MUX eFuse w/Integrated Reverse Current Protection, IMON & PG 20-WQFN -40 to 125 Visit Texas Instruments Buy

    BREAKING CAPACITY Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    relay 230v 6 pin

    Abstract: tk2r1 relay 230v 8 pin
    Text: Output elements Relay output 1 or 2 changeover relays, AgNi cadmium-free 2000 VA / 80 W. Rated power : 2000 V A / 80W. Maximum breaking current : 8 A AC 8 A DC. Minimum breaking current : 10 mA / 5 VDC. Voltage breaking capacity : 250V AC/VDC. Electrical life : 105 operations 8 A 250V resistive.


    Original
    PDF

    GZM4

    Abstract: No abstract text available
    Text: T-R4 time relays Terminals circuit / contacts Contact number & arrangement Contact material Max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Max. breaking capacity Min. breaking capacity Resistance


    Original
    T-R4E-2014-23-1012 GZM4 PDF

    GZM4

    Abstract: M42G MS1056 m92g
    Text: PIR4 with socket GZM4 interface relays Contacts Contact number & arrangement Contact material Max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Max. breaking capacity Min. breaking capacity Resistance


    Original
    GZT4-0040, GZT4-0035. PIR4-012DC-00LD PIR4-230AC-00LV GZT4-0035 GZM4 M42G MS1056 m92g PDF

    C250

    Abstract: No abstract text available
    Text: PIR2 with socket GZM2 interface relays Contacts Contact number & arrangement Contact material Max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Max. breaking capacity Min. breaking capacity Resistance


    Original
    GZT4-0040, GZT4-0035. PIR2-012DC-00LD PIR2-230AC-00LV GZT4-0035 C250 PDF

    B400

    Abstract: C250 EC35 GZT92 RM87 RM87N
    Text: RM87 miniature relays 77 RM87N sensitive Contacts Contact number & arrangement Contact material Max. switching voltage Min. switching voltage Rated load AC/DC AC1 DC1 Min. switching current Max. inrush current Rated current Max. breaking capacity Min. breaking capacity


    Original
    RM87N RM87N, RM87L, RM87P) B400 C250 EC35 GZT92 RM87 PDF

    DTH circuit diagram

    Abstract: DTH block diagram
    Text: MOULDED CASE CIRCUIT BREAKERS 2 DS Page DTH.E Page DG Page Adjustable Overload & Fixed Short-circuit Fixed Overload & Fixed Short-circuit Fixed Overload & Fixed Short-circuit release with Normal Breaking Capacity release with High Breaking Capacity Technical Data


    Original
    2/58ROTECTION DTH circuit diagram DTH block diagram PDF

    zen M20 CIRCUIT diagram

    Abstract: limit switch bracket film hot
    Text: Enclosed Switches ZE/ZV/ZV2/XE/XV/XV2 General-purpose Enclosed Switches with High Breaking Capacity and High Durability • Z General-purpose Basic Switches are built into ZE, ZV, and ZV2 Switches. They provided high durability and high breaking capacity.


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: RM87 miniature relays 77 RM87N sensitive Contact data Number and type of contacts Contact material Max. switching voltage Min. switching voltage Rated load AC/DC AC1 DC1 Min. switching current Max. inrush current Rated current Max. breaking capacity Min. breaking capacity


    Original
    RM87N RM87N, RM87L, RM87P) PDF

    Untitled

    Abstract: No abstract text available
    Text: 12 HelioFuse Product offering D  C120-123 1 100VDC Minimum Breaking Capacity = 2In; Maximum Breaking Capacity = 100kA Rated voltage Rated Current Size Cat. Number 50A 120 DC120GC12C050EF 1 63A 120 DC120GC12C063EF 1 80A 120 DC120GC12C080EF 1 100A 121 DC121GC12C100EF


    Original
    DC120-123 100VDC 100kA DC120GC12C050EF DC120GC12C063EF DC120GC12C080EF DC121GC12C100EF DC121GC12C125EF DC121GC12C160EF DC121GC12C200EF PDF

    gb10963

    Abstract: MINIATURE CIRCUIT BREAKER Breaking capacity IEC60898 mcb DATASHEET Breaking Capacity mcb circuit breaker GB109 AC miniature circuit breaker
    Text: XMB0 series high breaking capacity mini circuit breaker MCB XMB0 Series miniature circuit breaker is of high breaking capacity and current-limiting characteristic, with power insulated function. Dual-use terminal can connect with both bus bar and lead with optional insertion direction. MCB


    Original
    50Hz/60Hz, 230/400V, IEC60898 GB10963. gb10963 MINIATURE CIRCUIT BREAKER Breaking capacity mcb DATASHEET Breaking Capacity mcb circuit breaker GB109 AC miniature circuit breaker PDF

    EN60127

    Abstract: No abstract text available
    Text: B Fuses Fuses mm FX0287 FX0287/Rating. Approvals: BSI Glass, Time Delay T, anti-surge, low breaking capacity. C onstruction: Spiral element wound on fibreglass core. Conforms to EN60 127-2, Sheet 3. Breaking Capacity: 35A or 10 In whichever is greater @ cos


    OCR Scan
    FX0287 FX0287/Rating. FX0287 60min 200ms 600ms 150ms 10msecified EN60127 PDF

    DIN43625

    Abstract: 43625
    Text: PowerIT Current Limiting Fuses, CEF Rated voltage: 3,6/7,2-36 kV Rated current: 6-200 A Catalogue 1YMB631080-en • • • • • • Low minimum breaking current Low power losses,specially suitable in compact switchgearand ring main units High breaking capacity


    Original
    1YMB631080-en 1YMB631080-en DIN43625 43625 PDF

    Untitled

    Abstract: No abstract text available
    Text: SHF 6.3x32 Non resettable fuses www.schurter.com/PG01_2 Cartridge Fuse, 6.3x32 mm, 500 VAC, 1-8 A, High Breaking Capacity of 1500 A UL 248-14 • 500 VAC · Quick-Acting F Description Applications - High breaking capacity - High rated current - Pigtails optional


    Original
    com/PG01 E41599 PDF

    PT 10000

    Abstract: No abstract text available
    Text: SHT 6.3x32 Pigtail Non resettable fuses www.schurter.com/pg01_2 Axial Lead Fuse, 6.3x32 mm, 500 VAC, 1-8 A, high Breaking Capacity of 1500 A UL 248-14 • 500 VAC · Time-Lag T Description Applications - High breaking capacity - High rated current


    Original
    com/pg01 500VAC E41599 PT 10000 PDF

    Untitled

    Abstract: No abstract text available
    Text: SHT 6.3x32 Non resettable fuses www.schurter.com/pg01_2 Cartridge Fuse, 6.3x32 mm, 500 VAC, 1-8 A, high Breaking Capacity of 1500 A UL 248-14 • 500 VAC · Time-Lag T Description Applications - High breaking capacity - High rated current - More rated currents will follow


    Original
    com/pg01 E41599 Ra1400 PDF

    MST100

    Abstract: XS125 WM1003N 40118 hrc fuse 16.5ka tag 440 XS16 XS125 fuse GE xs35 NS32M40
    Text: SAFECLIP SAFECLIP HRC Fuse Links SAFECLIP BS 88-1 or 6:1988 SAFECLIP IEC 269-1 Applications Technical Data Current Rating Voltage Rating ac Breaking Capacity ac V up to 440 (kA) 80 Approvals Max Operating Ambient Temperature (°C) 40 ASTA 20 Certified Breaking Capacity


    Original
    63M80* 32M40 63M80 100M125 100M160 MST100 XS125 WM1003N 40118 hrc fuse 16.5ka tag 440 XS16 XS125 fuse GE xs35 NS32M40 PDF

    Untitled

    Abstract: No abstract text available
    Text: SHF 6.3x32 Pigtail Non resettable fuses www.schurter.com/PG01_2 Axial Lead Fuse, 6.3x32 mm, 500 VAC, 1-8 A, High Breaking Capacity of 1500 A UL 248-14 • 500 VAC · Quick-Acting F Description Applications - High breaking capacity - High rated current


    Original
    com/PG01 E41599 PDF

    7040.2120

    Abstract: x1kv
    Text: Surge Tolerant Cartridge Fuses FSU 5 x 20mm fuses SSU 5 x 20 mm fuses low breaking capacity L high breaking capacity H especially for telecom applications especially for telecom applications NEW NEW 1. Technical data Pre-arcing time/current characteristic at Ta 23 °C


    Original
    127tion: 7040.2120 x1kv PDF

    Untitled

    Abstract: No abstract text available
    Text: SHT 6.3x32 Non resettable fuses www.schurter.com/PG01_2 Cartridge Fuse, 6.3x32 mm, 500 VAC, 1-8 A, High Breaking Capacity of 1500 A UL 248-14 • 500 VAC · Time-Lag T Description Applications - High breaking capacity - High rated current - Pigtails optional


    Original
    com/PG01 E41599 PDF

    em-232

    Abstract: JET1037-31003-1008 ceramic fuse 500mA 250v
    Text: Type 5HT / 5HTP 5HT May 2012D Pb 5 x 20mm Ceramic Tube RoHS 6 Compliant Time-lag Fuse Series High - Breaking Capacity 5HT / 5HTP Series, 5 x 20mm Time-Lag Fuse Description 5x20mm Time-Lag surge withstand, high breaking capacity, ceramic body cartridge fuse designed,


    Original
    2012D 5x20mm IEC-127-2 63VDC. EIA-296-F em-232 JET1037-31003-1008 ceramic fuse 500mA 250v PDF

    Untitled

    Abstract: No abstract text available
    Text: Type 5HT / 5HTP 5HT May 2012D Pb 5 x 20mm Ceramic Tube RoHS 6 Compliant Time-lag Fuse Series High - Breaking Capacity 5HT / 5HTP Series, 5 x 20mm Time-Lag Fuse Description 5x20mm Time-Lag surge withstand, high breaking capacity, ceramic body cartridge fuse designed,


    Original
    2012D 5x20mm IEC-127-2 63VDC. 296-F 1234235678299A17 DEF89 953875B68299A17 7C32478299A17 PDF

    Untitled

    Abstract: No abstract text available
    Text: SHF 6.3x32 Non resettable fuses www.schurter.com/PG01_2 Cartridge Fuse, 6.3x32 mm, 500 VAC, 1-8 A, High Breaking Capacity of 1500 A UL 248-14 • 500 VAC · Quick-Acting F Description Applications - High breaking capacity - High rated current - Pigtails optional


    Original
    com/PG01 E41599 Distributor-Stock-00 PDF

    Untitled

    Abstract: No abstract text available
    Text: SHF 6.3x32 Pigtail Non resettable fuses www.schurter.com/PG01_2 Axial Lead Fuse, 6.3x32 mm, 500 VAC, 1-8 A, High Breaking Capacity of 1500 A UL 248-14 • 500 VAC · Quick-Acting F Description Applications - High breaking capacity - High rated current


    Original
    com/PG01 E41599 PDF

    Untitled

    Abstract: No abstract text available
    Text: SHT 6.3x32 Non resettable fuses www.schurter.com/PG01_2 Cartridge Fuse, 6.3x32 mm, 500 VAC, 1-8 A, high Breaking Capacity of 1500 A UL 248-14 • 500 VAC · Time-Lag T Description Applications - High breaking capacity - High rated current - More rated currents will follow


    Original