Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CLASS J BLOWN FUSE INDICATOR Search Results

    CLASS J BLOWN FUSE INDICATOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCKE800NA Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE800NL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE812NA Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE812NL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, Fixed Over Voltage Clamp, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE712BNL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 13.2 V, 3.65 A, Latch, Adjustable Over Voltage Protection, WSON10 Visit Toshiba Electronic Devices & Storage Corporation

    CLASS J BLOWN FUSE INDICATOR Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    LR29862

    Abstract: CLASS J blown fuse indicator blown fuse indicator APPLICATIONS
    Text: JTD_ID Series Indicator POWR-PRO Class J Fuses 600 VAC • Time Delay ■ 8/10 – 600 Amperes POWR-PRO FUSES SPECIFICATIONS Voltage ratings: AC: 600 Volts DC: Contact Factory Interrupting ratings: AC: 200,000 amperes rms symmetrical. 300,000 amperes rms symmetrical


    Original
    PDF E81895) LR29862) LR29862 CLASS J blown fuse indicator blown fuse indicator APPLICATIONS

    LR29862

    Abstract: blown fuse indicator APPLICATIONS
    Text: JTD_ID Series Indicator POWR-PRO Class J Fuses 600 VAC • Time Delay ■ 8/10 – 600 Amperes SPECIFICATIONS Voltage Ratings: AC: 600 Volts DC: Contact Factory Interrupting Ratings: AC: 200,000 amperes rms symmetrical 300,000 amperes rms symmetrical Littelfuse self-certified


    Original
    PDF E81895) LR29862) num15A LR29862 blown fuse indicator APPLICATIONS

    blown fuse indicator APPLICATIONS

    Abstract: LR29862 jtd 100 id
    Text: JTD_ID Series Indicator POWR-PRO Class J Fuses 600 VAC • Time Delay ■ 8/10 – 600 Amperes SPECIFICATIONS Voltage Ratings: AC: 600 Volts DC: Contact Factory Interrupting Ratings: AC: 200,000 amperes rms symmetrical 300,000 amperes rms symmetrical Littelfuse self-certified


    Original
    PDF E81895) LR29862) blown fuse indicator APPLICATIONS LR29862 jtd 100 id

    blown fuse indicator

    Abstract: datasheet of blown fuse indicator LR29862
    Text: POWR-PRO Fuses JTD_ID Series Indicator® POWR-PRO® Class J Fuses 600 VAC • Time Delay • 8/10 – 600 Amperes Applications POWR-PRO® Fuses Fused combination motor controllers to provide IEC Type 2 “No Damage” motor branch circuit short-circuit and ground fault


    Original
    PDF

    TI-600

    Abstract: of blown fuse indicator blown fuse TI600 ti-1500 CLASS J blown fuse indicator Ferraz ShawmuT AMPTRAP blown fuse indicator Ferraz Shawmut microswitches
    Text: BLOWN FUSE INDICATORS ACCESSORIES TRIGGER INDICATOR Before After The Trigger Indicator Catalog Number suffix TI is available on many blade type fuses, primarily Form 101 semiconductor fuses and some Class L fuses. The TI allows blown fuses to be identified visually, eliminating the need


    Original
    PDF TI-130) TI-600) TI-1500) TI-600 of blown fuse indicator blown fuse TI600 ti-1500 CLASS J blown fuse indicator Ferraz ShawmuT AMPTRAP blown fuse indicator Ferraz Shawmut microswitches

    blown fuse indicator APPLICATIONS

    Abstract: LPSG30-1MI LPSG30-2MI LPSG30-3MI LPSG60-1MI CLASS J blown fuse indicator
    Text: Introducing the Global Pro System Offering World Class Performance and Global Acceptance The International Challenge The benefits of the Global Pro System include: Engineers and equipment designers are faced with a dilemma when choosing the right circuit protection for their


    Original
    PDF LPSG30-1MI LPSG30-2MI LPSG30-3MI LPSG60-1MI LPSG60-2MI LPSG60-3MI LPSG100-1MI LPSG100-2MI LPSG100-3MI 1-800-TEC-FUSE blown fuse indicator APPLICATIONS LPSG30-1MI LPSG30-2MI LPSG30-3MI LPSG60-1MI CLASS J blown fuse indicator

    Littelfuse FLNR 30

    Abstract: FLSR_ID FLSR100ID LR600 LR250 LR29862 250 volt to 600 volt fuse
    Text: FLNR_ID/FLSR_ID IndicatorTM Class RK5 Fuses 250/600 VAC • Dual-Element, Time Delay ■ 1/10 – 600 Amperes SPECIFICATIONS Voltage Ratings: AC: 250 Volts FLNR_ID ; 600 Volts (FLSR_ID) DC: 125 Volts (FLNR 1/10 – 30A); 125 Volts (FLNR_ID 35 – 600A); 300 Volts (FLSR_ID)


    Original
    PDF E81895) LR29862) WF-1814 Littelfuse FLNR 30 FLSR_ID FLSR100ID LR600 LR250 LR29862 250 volt to 600 volt fuse

    E81895

    Abstract: FLSR100ID LR250 LR29862 LR600 QPL - 8000 Series
    Text: FLNR_ID/FLSR_ID IndicatorTM Class RK5 Fuses 250/600 VAC • Dual-Element, Time Delay ■ 1/10 – 600 Amperes SPECIFICATIONS Voltage ratings: AC: 250 Volts FLNR_ID ; 600 Volts (FLSR_ID) DC: 125 Volts (FLNR 1/10-30A); 125 Volts (FLNR_ID 35-600A); GENERAL 300 Volts (FLSR_ID)


    Original
    PDF 1/10-30A) 5-600A) E81895) LR29862) E81895MPERES E81895 FLSR100ID LR250 LR29862 LR600 QPL - 8000 Series

    Littelfuse 16A 250v fuse

    Abstract: FLSR100ID LR250 LR29862 LR600 Littelfuse FLNR 30 6002F FLSR_ID FLS-R-10
    Text: General Purpose Fuses FLNR_ID/FLSR_ID Indicator Class RK5 Fuses 250/600 VAC • Dual-Element, Time Delay • 1/10 – 600 Amperes Applications General Purpose Fuses Service entrance switches Switchboard main and feeder switches Motor control center mains and motor branch circuits


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: General Purpose Fuses FLNR_ID/FLSR_ID Indicator Class RK5 Fuses 250/600 VAC • Dual-Element, Time Delay • 1/10 – 600 Amperes Applications General Purpose Fuses Service entrance switches Switchboard main and feeder switches Motor control center mains and motor branch circuits


    Original
    PDF

    Ferraz Shawmut cms 101

    Abstract: holder fuse CMS 101 ferraz protistor 600v ferraz protistor 660V AC 80A ferraz protistor fuse cc1051 dc motor controller forklift holder fuse CMS 101 ferraz Ferraz Shawmut fuse 315A ferraz protistor ferraz protistor 660V AC 400A
    Text: Product Guide Product Guide Amp-Trap 2000 Fuses AJT A2D & A6D A4BQ ATDR & ATQR Class J Time Delay 1 to 600A 600V AC, 200kA I.R. 300kA I.R. UL Witnessed 500V DC, 100kA I.R. Current Limiting UL Listed CSA Certified Smart Spot Indicator Motor, motor controller, control


    Original
    PDF 200kA 300kA 100kA Ferraz Shawmut cms 101 holder fuse CMS 101 ferraz protistor 600v ferraz protistor 660V AC 80A ferraz protistor fuse cc1051 dc motor controller forklift holder fuse CMS 101 ferraz Ferraz Shawmut fuse 315A ferraz protistor ferraz protistor 660V AC 400A

    Untitled

    Abstract: No abstract text available
    Text: AJT Time-delay/Class J SmartSpot with maximum circuit protection Amp-Trap 2000® SmartSpot AJT fuses now provide a visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they


    Original
    PDF 600VAC 0-600A

    LR21455

    Abstract: 6J60A3B 6SM30A2 6CC30A1SPQ 6SC30A2-C 6CC30A3SPQ CLASS J blown fuse indicator 6M30A3S 6SM30A3 6SM30A2I
    Text: 1264-2012.qxp:QuarkCatalogTempNew 9/4/12 7:00 AM Page 1264 POWER ENCLOSURES INTERCONNECT TEST & MEASUREMENT 14 Fuse Holders Applications. Marathon Fuse Holders can be used in various applications, including control panels, lighting and heating circuits, motor circuits, circuit breaker protection, switchgear equipment, appliances, electric heat, air conditioning and refrigeration


    Original
    PDF E35113 UL4248-1 FSM25E FSM37E FSM50E LR21455 6J60A3B 6SM30A2 6CC30A1SPQ 6SC30A2-C 6CC30A3SPQ CLASS J blown fuse indicator 6M30A3S 6SM30A3 6SM30A2I

    JTD60ID

    Abstract: LR29862
    Text: POWR-GARD Fuse Datasheet UL Class J JTD_ID Series Indicator ® POWR-PRO ® FUSES 600 VAC • Time Delay • 8 /10 – 600 Amperes Specifications Voltage Ratings: AC: DC: 600 V 300 V 8 ⁄10 –100 A ; 500 V (110–600 A) Interrupting Rating: AC: 


    Original
    PDF E81895) LR29862) JTD60ID LR29862

    LPSG100-3MI

    Abstract: of blown fuse indicator LPSG30-3MI LPSG100-1MI LPSG100-2MI LPSG30-1MI LPSG30-2MI LPSG60-1MI
    Text: International Products LPSG Series Global Pro Fuseholders Applications • • • • Motor control centers Motor branch circuits Primary and secondary protection for transformers Equipment designed for export Features And Benefits The Global Pro Fuseholder also accepts IEC dimension cartridge style


    Original
    PDF LPSG30-1MI LPSG30-2MI LPSG30-3MI LPSG60-1MI LPSG60-2MI LPSG60-3MI LPSG100-1MI LPSG100-2MI LPSG100-3MI 200kA LPSG100-3MI of blown fuse indicator LPSG30-3MI LPSG100-1MI LPSG100-2MI LPSG30-1MI LPSG30-2MI LPSG60-1MI

    Untitled

    Abstract: No abstract text available
    Text: International Products LPSG Series Global Pro Fuseholders Applications • • • • Motor control centers Motor branch circuits Primary and secondary protection for transformers Equipment designed for export Features And Benefits The Global Pro Fuseholder also accepts IEC dimension cartridge style


    Original
    PDF LPSG30-1MI LPSG30-2MI LPSG30-3MI LPSG60-1MI LPSG60-2MI LPSG60-3MI LPSG100-1MI LPSG100-2MI LPSG100-3MI 200kA

    CLASS J blown fuse indicator

    Abstract: of blown fuse indicator E71611
    Text: LgD Series Global ProTM-tection Fuses 600 Volts AC • GlobalPro Time-Delay ■ 1 – 100 Amperes GLOBAL CIRCUIT PROTECTION SPECIFICATIONS Voltage Ratings: 600 Volts AC UL 690 Volts AC (IEC) Interrupting Rating: AC: 200,000 amperes rms symmetrical Ampere Range: 1 – 100* amperes


    Original
    PDF E71611) LR29862) CLASS J blown fuse indicator of blown fuse indicator E71611

    Untitled

    Abstract: No abstract text available
    Text: Technical Datasheet 1SNK162045D0201 Catalogue Page 1SNK162022S0201 ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator - Protect your circuits with 5x20 fuse terminal blocks compliant with IEC 60947-7-3 standard fuse not supplied


    Original
    PDF 1SNK162045D0201 1SNK162022S0201 1SNK162091V0014 1SNK500181F0000 1SNC500511 F0000 F-69685 1SNK162045D0201

    1492-IFM40

    Abstract: 1492-IFM40F Allen-Bradley 1746-OW16 1492-IFM40F-2 1746-IB16 1746-OW16 1492-IFM40F-F24-2 1492-IFM20F-F24-2 1492-IFM40D24A-2 1492IFM40F2
    Text: A–B ALLENĆBRADLEY PLC/SLC Wiring Systems Interface Modules and Cables Bulletin 1492 Product Data 94Ć593Ć8 Contents 93Ć242Ć2 94Ć593Ć7 This product data contains: Section Description Features and Benefits of IFMs (Interface Modules) and PreĆwired Cables


    Original
    PDF Specifications10 1492-IFM40 1492-IFM40F Allen-Bradley 1746-OW16 1492-IFM40F-2 1746-IB16 1746-OW16 1492-IFM40F-F24-2 1492-IFM20F-F24-2 1492-IFM40D24A-2 1492IFM40F2

    LFJ60

    Abstract: din 68-150
    Text: POWR-GARD Fuse Datasheet JTD Series Indicator ® POWR-PRO ® FUSES 600 VAC • Time Delay • 8 /10 -600 A Specifications Voltage Ratings AC : 600 V DC: 300 V 8 ⁄10 –100 A 500 V (110–600 A) 8 ⁄10 –600 A AC: 200 kA rms symmetrical


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: POWR-GARD Fuse Datasheet JTD Series Indicator ® POWR-PRO ® FUSES 600 Vac • Time Delay • 8 /10 -600 A Specifications Voltage Ratings AC: 600 V DC: 300 V 8 ⁄10 –100 A 500 V (110–600 A) 8 ⁄10 –600 A AC: 200 kA rms symmetrical


    Original
    PDF E81895) LR29862)

    Untitled

    Abstract: No abstract text available
    Text: POWR-GARD Fuse Datasheet JTD SERIES INDICATOR ® POWR-PRO ® FUSES 600 VAC • Time Delay • 8 /10 -600 A Specifications AC : 600 V DC: 300 V 8 ⁄10 –100 A 500 V (110–600 A) 8 ⁄10 –600 A AC: 200 kA rms symmetrical 300 kA rms symmetrical DC: 20 kA


    Original
    PDF E81895) LR29862) and80

    Untitled

    Abstract: No abstract text available
    Text: IDSR Series Indicator POWR-PRO Class RK5 600 V AC/DC • Time-Delay ■ 1/10 – 600 Amperes POWR-PRO FUSES SPECIFICATIONS Voltage ratings: AC: 600 Volts DC: 600 Volts Min. 75 volts AC/DC required for indication Interrupting ratings: AC: 200,000 amperes rms symmetrical


    Original
    PDF E81895) LR29862)

    S330020

    Abstract: Z330187 R330111 C330029 y330025 R330019 w330184 V330183 X330185 T330021
    Text: y«\44< *> Semiconductor Fuses European Fuses DIN 000 Fuses 6,6 gRB-URB - 5 URB GERMAN STANDARD 500 - 660 V AC gRB- URB from 20 to 400 A Size: 000 EXTREMELY HIGH INTERRUPTING RATING FUSES: PROTECTION OF POWER SEMICONDUCTORS ACCORDING TO 269.1 AND 4 500- 660 V VOLTAGE RATING RATING 20 TO 400 A


    OCR Scan
    PDF 43653-00C S330020 Z330187 R330111 C330029 y330025 R330019 w330184 V330183 X330185 T330021