Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    DEBOUNCING TIMER Search Results

    DEBOUNCING TIMER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    N82C54-2 Rochester Electronics LLC Programmable Timer, CMOS Visit Rochester Electronics LLC Buy
    P82C54-2 Rochester Electronics LLC Programmable Timer, CMOS Visit Rochester Electronics LLC Buy
    MC6840CFN-G Rochester Electronics LLC MC6840 - Programmable Timer Module(PTM) Visit Rochester Electronics LLC Buy
    MC6840CP-G Rochester Electronics LLC MC6840 - Programmable Timer Module(PTM) Visit Rochester Electronics LLC Buy
    MR8254/R Rochester Electronics LLC 8254 - Programmable Interval Timer Visit Rochester Electronics LLC Buy

    DEBOUNCING TIMER Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    bach prelude

    Abstract: Bach 001H 018H ACE1202 AN-2005 ACE Fairchild JPH2000
    Text: AN-2005 Debouncing Input Switches Using the ACE Fairchild App Note 2005 July 2000 1.0 Introduction state. If debouncing is not implemented, the microcontroller may read these rapid transitions as rapidly switching on/off signals and malfunction as a result. The principle of key debouncing is to wait


    Original
    AN-2005 interr793-856858 AN-2005 bach prelude Bach 001H 018H ACE1202 ACE Fairchild JPH2000 PDF

    12c508 timer

    Abstract: 12C508 debouncing 12C508 APPLICATION P12C508 PIC12C5XX 12c508 based timer DS40160A 12c508/p04
    Text: Consumer Appliance, Widget, Gadget Debouncing 8 Buttons in 7 Clock Cycles Author: Marc Hoffknecht Aachen, Germany email: [email protected] APPLICATION OPERATION: The code fragment described here is capable of protecting against noise and debouncing with eight button


    Original
    PIC12C5xx 12C508 DS40160A/5 001-page 12c508 timer 12C508 debouncing 12C508 APPLICATION P12C508 12c508 based timer DS40160A 12c508/p04 PDF

    A0926

    Abstract: 10v ZENER DIODE
    Text: HV301/HV311 HV301/HV311 Hot Swap Controller Negative Supply Rail Ordering Information Features ! ! ! ! ! ! ! ! ! ! ! ! ! ±10V to ±90V Operation Built-in “normally on” turn-on clamp eliminates components UV/OV Lock Out & Power-on-Reset for Debouncing


    Original
    HV301/HV311 HV301/HV311 A092605 A0926 10v ZENER DIODE PDF

    6020EC

    Abstract: No abstract text available
    Text: APPLICATION NOTE M16C/26 Using Timer A in One-Shot Mode 1.0 Abstract One-shot timers are commonly found in designs, as they are useful for debouncing switches, “cleaning” up sensor inputs, etc. Timer A on the M16C/26 can be configured as one-shots, reducing the need for external


    Original
    M16C/26 M16C/26 M30262 16-bit M16C/60 6020EC PDF

    IRF530 application

    Abstract: hv301 hv311 HV311 HV301 HV301LG HV311LG IRF530 dc to dc converter 48v to 12v 10a diagram
    Text: HV301/HV311 HV301/HV311 Hot Swap Controller Negative Supply Rail Ordering Information Features ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ±10V to ±90V Operation Built-in “normally on” turn-on clamp eliminates components UV/OV Lock Out & Power-on-Reset for Debouncing


    Original
    HV301/HV311 A092605 IRF530 application hv301 hv311 HV311 HV301 HV301LG HV311LG IRF530 dc to dc converter 48v to 12v 10a diagram PDF

    microcontroller relay interfacing

    Abstract: stocker yale SWITCH debouncing abstract for robotics project advantages of microcontroller -based relay 102B 74HC14 MAX1617 MAX6816 MAX6817
    Text: Maxim > App Notes > SWITCHES AND MULTIPLEXERS Keywords: switch debouncers, 15kV, ESD, switch protection, debouncing, Jul 24, 2001 APPLICATION NOTE 764 Interfacing Switches and Relays to the Real World in Real Time Abstract: This note discusses the effects on switches when used to connect loads. High currents through a


    Original
    MAX6816/MAX6817/MAX6818 com/an764 MAX6816: MAX6818: AN764, APP764, Appnote764, microcontroller relay interfacing stocker yale SWITCH debouncing abstract for robotics project advantages of microcontroller -based relay 102B 74HC14 MAX1617 MAX6816 MAX6817 PDF

    Untitled

    Abstract: No abstract text available
    Text: APPLICATION NOTE M16C/62 Using the M16C/62 Timers in One-Shot Mode 1.0 Abstract One-shots are commonly found in designs because they are useful for debouncing switches, “cleaning” up sensor inputs, and so on. The A timers on the M16C/62 can be configured as one-shots, reducing the need for


    Original
    M16C/62 M16C/62 16-bit PDF

    CRC16-polynomial circuit design

    Abstract: CRC16 DS2423 DS2423P DS2423X
    Text: DS2423 4kbit 1-Wire RAM with Counter www.maxim-ic.com FEATURES § § § § § § § § § § § 4096 bits of SRAM Four 32-bit, read-only counters Active-low external trigger inputs for two of the counters with on-chip debouncing compatible with reed and Wiegand switches


    Original
    DS2423 32-bit, 64-bit 48bit 256-bit 16-bit CRC16-polynomial circuit design CRC16 DS2423 DS2423P DS2423X PDF

    DS2423

    Abstract: CRC16 DS2423P DS2423X CRC16-polynomial circuit design DS2423 equivalent
    Text: DS2423 4kbit 1-Wire RAM with Counter www.maxim-ic.com FEATURES § § § § § § § § § § § 4096 bits of SRAM Four 32-bit, read-only counters Active-low external trigger inputs for two of the counters with on-chip debouncing compatible with reed and Wiegand switches


    Original
    DS2423 32-bit, 64-bit 48bit 256-bit 16-bit DS2423 CRC16 DS2423P DS2423X CRC16-polynomial circuit design DS2423 equivalent PDF

    IRF530

    Abstract: No abstract text available
    Text: HV301/HV311 HV301 HV311 Hot Swap Controller Negative Supply Rail Features ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Ordering Information ±10V to ±90V Operation Built-in “normally on” turn-on clamp eliminates components UV/OV Lock Out & Power-on-Reset for Debouncing


    Original
    HV301/HV311 HV301 HV311 IRF530 PDF

    U840B

    Abstract: U840B-FP debouncing relay contact
    Text: U840B Digital / Wipe-Wash Control for Rear or Front Wiper Description The circuits U840B DIP8 and U840B-FP (SO8) are designed as interval wipe/ wash timer for automotive applications. The interval pause t3 can be set in a range from 0.8 s to 22 s by an external 30 kW potentiometer. All


    Original
    U840B U840B-FP D-74025 03-Feb-97 U840B U840B-FP debouncing relay contact PDF

    SWITCH debouncing

    Abstract: DOWNLOAD DATA ABOUT RELAY SWITCH U840B U840B-FP
    Text: U840B Digital Interval Wipe/ Wash Control for Rear/ Front Wiper Description The circuit U840B is designed as interval wipe/ wash timer for automotive applications. The interval pause can be set in a range from 0.8 s to 22 s by an external 30 kW potentiometer. All other time periods are determined by


    Original
    U840B U840B D-74025 27-Mar-01 SWITCH debouncing DOWNLOAD DATA ABOUT RELAY SWITCH U840B-FP PDF

    U840B

    Abstract: U840B-FP
    Text: U840B Digital Interval Wipe/Wash Control for Rear or Front Wiper Description The circuit U840B is designed as interval wipe/ wash timer for automotive applications. The interval pause can be set in a range from 0.8 s to 22 s by an external 30 kW potentiometer. All other time periods are determined by


    Original
    U840B U840B D-74025 07-Jun-99 U840B-FP PDF

    U840B

    Abstract: U840B-FP
    Text: U840B Digital Interval Wipe/Wash Control for Rear or Front Wiper Description The circuit U840B is designed as interval wipe/ wash timer for automotive applications. The interval pause can be set in a range from 0.8 s to 22 s by an external 30 kW potentiometer. All other time periods are determined by


    Original
    U840B U840B D-74025 02-Dec-97 U840B-FP PDF

    automotive relay driver IC

    Abstract: U840B U840B-FP
    Text: U840B Digital Interval Wipe/ Wash Control for Rear/ Front Wiper Description The circuit U840B is designed as interval wipe/ wash timer for automotive applications. The interval pause can be set in a range from 0.8 s to 22 s by an external 30 kW potentiometer. All other time periods are determined by


    Original
    U840B U840B D-74025 21-Aug-00 automotive relay driver IC U840B-FP PDF

    wiper motor

    Abstract: T4D DIODE U842B v6 4d zener diode wipe wash
    Text: U842B Wiper Control for Intermittent and Wipe/ Wash Mode Description The U842B circuit is designed as an interval and wipe/ wash timer for automotive wiper control. The interval pause can be set in a range from 3 s to 11 s by an external 1-kW potentiometer. Wipe/wash mode has


    Original
    U842B U842B D-74025 03-Feb-97 wiper motor T4D DIODE v6 4d zener diode wipe wash PDF

    TRANSISTOR nf 842

    Abstract: wiper motor U842B operation of wiper motor and relay wipe wash
    Text: U 842 B TELEFUNKEN Semiconductors Wiper control for Intermittent and Wipe/ Wash Mode Description The U 842 B circuit is designed as an interval and wipe/ wash timer for automotive wiper control. The interval pause can be set in a range from 3 s to 11 s by


    Original
    88/540/EEC 91/690/EEC TRANSISTOR nf 842 wiper motor U842B operation of wiper motor and relay wipe wash PDF

    Untitled

    Abstract: No abstract text available
    Text: Tem ic U842B S e m i c o n d u c t o r s Wiper Control for Intermittent and Wipe/ Wash Mode Description The U842B circuit is designed as an interval and wipe/ wash timer for automotive wiper control. The interval pause can be set in a range from 3 s to 11 s by an


    OCR Scan
    U842B U842B D-74025 07-Jun-99 PDF

    td3400

    Abstract: U840B U840B-FP 12 V RELAY
    Text: Temic U840B S e m i c o n d u c t o r s Digital / Wipe-Wash Control for Rear or Front Wiper Description The circuits U840B DIP8 and U840B-FP (S08) are designed as interval wipe/ wash timer for automotive applications. The interval pause t3 can be set in a range


    OCR Scan
    u840b U840B-FP D-74025 03-Feb-97 td3400 U840B U840B-FP 12 V RELAY PDF

    Untitled

    Abstract: No abstract text available
    Text: Tem ic U840B S e m i c o n d u c t o r s Digital Interval Wipe/Wash Control for Rear or Front Wiper Description The circuit U840B is designed as interval wipe/ wash timer for automotive applications. The interval pause can be set in a range from 0.8 s to 22 s by an external 30 kQ


    OCR Scan
    U840B U840B D-74025 07-Jun-99 PDF

    ti67

    Abstract: No abstract text available
    Text: Tem ic U840B S e m i c o n d u c t o r s Digital Interval Wipe/Wash Control for Rear or Front Wiper Description The circuit U840B is designed as interval wipe/ wash timer for automotive applications. The interval pause can be set in a range from 0.8 s to 22 s by an external 30 kQ


    OCR Scan
    U840B U840B D-74025 02-Dec-97 ti67 PDF

    long deLAY ic timer relay

    Abstract: No abstract text available
    Text: Tem ic U842B S e m i c o n d u c t o r s Wiper Control for Intermittent and Wipe/ Wash Mode Description The U842B circuit is designed as an interval and wipe/ wash timer for automotive wiper control. The interval pause can be set in a range from 3 s to 11 s by an


    OCR Scan
    U842B U842B D-74025 02-Dec-97 long deLAY ic timer relay PDF

    automotive relay driver IC

    Abstract: No abstract text available
    Text: Tem ic U842B S e m i c o n d u c t o r s Wiper Control for Intermittent and Wipe/ Wash Mode Description The U842B circuit is designed as an interval and wipe/ wash timer for automotive wiper control. The interval pause can be set in a range from 3 s to 11 s by an


    OCR Scan
    U842B U842B D-74025 07-Apr-99 automotive relay driver IC PDF

    Thermal resistance DIP8

    Abstract: U842B diode 1-35 L V6 automotive relay driver circuit using darlington U842B-FP wiper motor
    Text: Tem ic U842B S e m i c o n d u c t o r s Wiper Control for Intermittent and Wipe/ Wash Mode Description The U842B circuit is designed as an interval and wipe/ wash timer for automotive wiper control. The interval pause can be set in a range from 3 s to 11 s by an


    OCR Scan
    u842b U842B D-74025 03-Feb-97 Thermal resistance DIP8 diode 1-35 L V6 automotive relay driver circuit using darlington U842B-FP wiper motor PDF