Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    EN 61373 CATEGORY 1 CLASS B Search Results

    EN 61373 CATEGORY 1 CLASS B Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MP-5XRJ45UNNE-007 Amphenol Cables on Demand Amphenol MP-5XRJ45UNNE-007 Category 5E 3/4/176900Base-T Crossover Cable, RJ45 / RJ45 7ft Datasheet
    MP-5XRJ45UNNE-003 Amphenol Cables on Demand Amphenol MP-5XRJ45UNNE-003 Category 5E 3/4/176900Base-T Crossover Cable, RJ45 / RJ45 3ft Datasheet
    MP-5XRJ45UNNE-010 Amphenol Cables on Demand Amphenol MP-5XRJ45UNNE-010 Category 5E 3/4/176900Base-T Crossover Cable, RJ45 / RJ45 10ft Datasheet
    MP-5XRJ45UNNE-025 Amphenol Cables on Demand Amphenol MP-5XRJ45UNNE-025 Category 5E 3/4/176900Base-T Crossover Cable, RJ45 / RJ45 25ft Datasheet
    MP-5XRJ45UNNE-005 Amphenol Cables on Demand Amphenol MP-5XRJ45UNNE-005 Category 5E 3/4/176900Base-T Crossover Cable, RJ45 / RJ45 5ft Datasheet

    EN 61373 CATEGORY 1 CLASS B Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    st 6062

    Abstract: st1-16v
    Text: Technical data sheet • Relay Module Subject to technical modification 762120 Identification Use/Area of application Description Input Nominal voltage UN Voltage range Rated current at UN Status Indication Rated insulation voltage Input voltage Interrupting voltage


    Original
    EN50155/61373 st 6062 st1-16v PDF

    3 phase monitoring relays

    Abstract: No abstract text available
    Text: Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. Characteristics –– Monitoring of three-phase mains for phase sequence and


    Original
    V0012 3 phase monitoring relays PDF

    G221

    Abstract: No abstract text available
    Text: Extract from the online catalog PLC-RSP- 24UC/21/RW Order No.: 2987011 6.2 mm PLC complete relay module with spring-cage connections for railway applications, input nominal voltage 24 V DC, range: 0.7 x UN to


    Original
    24UC/21/RW IF-2009) 24UC/21/RW G221 PDF

    EN 61373 Category 1 Class B

    Abstract: CN200 EN50155 IEC60571 CN30A110 CN200A CN100A110-12 CN200A110
    Text: • 60 - 160VDC Input to EN50155/IEC60571 • EN/IEC 61373 Shock and Vibration • Base plate Cooled • Full Power at 100°C base plate • Five Year Warranty Key Market Segments & Applications Railway Applications Suitable for battery powered railway systems


    Original
    160VDC EN50155/IEC60571 110VDC CN30A110, CN50A110, CN100A110, CN200A110 Sept10 EN 61373 Category 1 Class B CN200 EN50155 IEC60571 CN30A110 CN200A CN100A110-12 CN200A110 PDF

    IEC60571

    Abstract: EN 61373 Category 1 Class B CN200 NEMIC-LAMBDA Nemic-Lambda CN EN50155 battery EX34 CN30A110 CN100A110-24 CN50A110-24
    Text: • 60 - 160VDC Input to EN50155/IEC60571 • EN/IEC 61373 Shock and Vibration • Base plate Cooled • Full Power at +100°C base plate • Five Year Warranty Key Market Segments & Applications Railway Applications Suitable for battery powered railway systems


    Original
    160VDC EN50155/IEC60571 110VDC CN30A110, CN50A110, CN100A110, CN200A110 Jan11 IEC60571 EN 61373 Category 1 Class B CN200 NEMIC-LAMBDA Nemic-Lambda CN EN50155 battery EX34 CN30A110 CN100A110-24 CN50A110-24 PDF

    Untitled

    Abstract: No abstract text available
    Text: Data sheet Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages The CM-ESS.1 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of phase loss. Characteristics –– Monitoring of DC and AC voltages 3-600 V


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.21 and CM-MPS.41 Characteristics –– Monitoring of three-phase mains for phase sequence can be switched off , phase failure, over- and undervoltage as well as phase unbalance –– TRMS measuring principle


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: www.martekpower.com www.martekpower.fr ICR 007, 016, 035 DC/AC INVERTERS FOR RAILWAY APPLICATIONS > Description This series of inverters is designed to supply interior fluorescent tubes in rolling stocks applications. Depending on its different versions, it is possible to supply 1 or 2 tubes from 5 W to


    Original
    V/100ms 01V/100ms 54V/100ms STM-E-001 PDF

    Untitled

    Abstract: No abstract text available
    Text: Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of phase loss. Characteristics –– Monitoring of DC and AC voltages 3-600 V


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Technical data sheet • Timing relay module DC 24–110 V, programmable with positive action contacts Subject to technical modification 815008.00 Identification Product version Datasheet version Use/Area of application Description Interfaces UART Interface


    Original
    ZR6-5008 PDF

    Untitled

    Abstract: No abstract text available
    Text: Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that monitors single-phase mains DC or AC for over- and undercurrent from 3 mA to 15 A. Characteristics –– Monitoring of DC and AC currents (3 mA to 15 A)


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: 13/11/2012 www.crouzet.com Resin board version NBR26 Part number 88973063 Vibration resistance Extended temperature range Outputs via removable connectors IP50 seal connectors DB 9-pin programming port via standard RS 232 cable Designed for application-specific functions


    Original
    NBR26 NBR26 PDF

    ABB STOTZ-KONTAKT S 211

    Abstract: HC-49/ABB STOTZ-KONTAKT S 211
    Text: Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31 and CM-PVS.41 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage. Characteristics –– Monitoring of three-phase mains for phase sequence


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: 27/05/2014 www.crouzet.com Resin board version NBR26 Part number 88973061 Vibration resistant Extended temperature range Outputs via removable connectors IP50 seal connectors DB 9-pin programming port via standard RS 232 cable Designed for application-specific functions


    Original
    NBR26 NBR26 Pt100 PDF

    Untitled

    Abstract: No abstract text available
    Text: 27/05/2014 www.crouzet.com Resin board version NBR12 Part number 88973001 Vibration resistant Extended temperature range Outputs via removable connectors IP50 seal connectors DB 9-pin programming port via standard RS 232 cable Designed for application-specific functions


    Original
    NBR12 NBR12 NBR12, Pt100 PDF

    EN 61373 Category 1 Class B

    Abstract: XD26
    Text: 05/09/2012 www.crouzet.com Resin board version NBR26 Part number 88973062 Vibration resistance Extended temperature range Outputs via removable connectors IP50 seal connectors DB 9-pin programming port via standard RS 232 cable Designed for application-specific functions


    Original
    NBR26 NBR12 NBR32 NBR40 NBR26 EN 61373 Category 1 Class B XD26 PDF

    Untitled

    Abstract: No abstract text available
    Text: 27/05/2014 www.crouzet.com Resin board version NBR32 Part number 88973211 Vibration resistant Extended temperature range Outputs via removable connectors IP50 seal connectors DB 9-pin programming port via standard RS 232 cable Designed for application-specific functions


    Original
    NBR32 NBR32 Pt100 PDF

    Untitled

    Abstract: No abstract text available
    Text: 27/05/2014 www.crouzet.com Resin board version NBR12 Part number 88973002 Vibration resistant Extended temperature range Outputs via removable connectors IP50 seal connectors DB 9-pin programming port via standard RS 232 cable Designed for application-specific functions


    Original
    NBR12 NBR12 NBR12, Pt100 PDF

    Untitled

    Abstract: No abstract text available
    Text: 27/05/2014 www.crouzet.com Resin board version NBR40 Part number 88973231 Vibration resistant Extended temperature range Outputs via removable connectors IP50 seal connectors DB 9-pin programming port via standard RS 232 cable Designed for application-specific functions


    Original
    NBR40 NBR40 Pt100 PDF

    Untitled

    Abstract: No abstract text available
    Text: 27/05/2014 www.crouzet.com Resin board version NBR26 Part number 88973062 Vibration resistant Extended temperature range Outputs via removable connectors IP50 seal connectors DB 9-pin programming port via standard RS 232 cable Designed for application-specific functions


    Original
    NBR26 NBR26 Pt100 PDF

    NBR12

    Abstract: NBR26 25AWG16 EN 61373 Category 1 Class B DIN EN 60068-2-2
    Text: 05/09/2012 www.crouzet.com Resin board version NBR26 Part number 88973061 Vibration resistance Extended temperature range Outputs via removable connectors IP50 seal connectors DB 9-pin programming port via standard RS 232 cable Designed for application-specific functions


    Original
    NBR26 NBR12 NBR32 NBR40 NBR26 25AWG16 EN 61373 Category 1 Class B DIN EN 60068-2-2 PDF

    DTREN150002

    Abstract: No abstract text available
    Text: CIR-M12 Series Databus Connectors Catalog VEAM CIR-M12 Series Connectors Product Overview VEAM’s retention clip provides secure retention of the contact in the insulator. In addition, through use of a specially designed tool, the contact is easily removed for


    Original
    CIR-M12 DTREN150002 PDF

    Untitled

    Abstract: No abstract text available
    Text: Technical Specification RQ1BxxxQMXxx Rail Grade DC-DC Power Supply 66-160V Continuous Input 200V/170V 5.0-24V Transient Input Outputs 50W Max Power 3000Vdc REINFORCED Insulation Quarter-brick DC-DC Converter Protection Features ►Input under-voltage lockout


    Original
    6-160V 00V/170V 3000Vdc PDF

    Untitled

    Abstract: No abstract text available
    Text: Technical Specification RQ68xxxQMXxx Rail Grade DC-DC Power Supply 12-150V Continuous Input 170V Transient Input 5.0-24V Outputs Protection Features Input under-voltage lockout Output current limit and short circuit protection Active back bias limit Output over-voltage protection


    Original
    RQ68xxxQMXxx 2-150V 3000Vdc PDF