Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    EN60950 EN41003 Search Results

    EN60950 EN41003 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    EN41003

    Abstract: BS6305 TLA4529 TLA4529-1 TLA4529-2
    Text: Audio TLA4529 Line Matching Transformer TLA4529 is a 1:1 line matching transformer with the following features. • BABT certified for reinforced reinforced inDesigned to meet sulation totoEN41003 & & insulation EN609500 EN60950. . EN41003 Certificate #: CT/T/0054


    Original
    PDF TLA4529 TLA4529 EN41003 EN609500 EN60950. CT/T/0054 AS3260 BS6305) EN41003 BS6305 TLA4529-1 TLA4529-2

    EIA 481-A IEC 286-3

    Abstract: 300SMD Critchley 85x Resistor CRITCHLEY transformer
    Text: CRITCHLEY IOOSMD ISSUE B - 08110197 A compact encapsulated line isolating transformer, BABT and BSi certified to EN41003:1993. The component is BSi certified to EN60950:1992 IEC950 for reinforced isolation (Certificate Nos. 7082 and 7456). ELECTRICAL SPECIFICATION


    Original
    PDF 250mV EN41003 EN60950 IEC950) 200Hz 2000Hz 4000Hz EIA 481-A IEC 286-3 300SMD Critchley 85x Resistor CRITCHLEY transformer

    T-995

    Abstract: EN41003 en60950
    Text: ISDN "S" Interface Transformer Reinforced Insulation per EN41003/EN60950 Turns Ratio 1CT:2CT PARAMETER @25oC Inductance MIN. MAX. 25 Leakage Inductance UNITS mH 20 µH Primary DC Resistance 2.0 3.0 Ohms Secondary DC Resistance 2.8 4.2 Ohms 10 pF Interwinding Capacitance


    Original
    PDF EN41003/EN60950 T-995 T-995 EN41003 en60950

    Untitled

    Abstract: No abstract text available
    Text: P Premier M Magnetics Inc. "INNOVATORS IN MAGNETICS TECHNOLOGY" T1/CEPT/ISDN-PRI 3KV - REINFORCED THRU-HOLE TRANSFORMERS Ê Reinforced Insulation Per EN41003/EN60950 Ë 3000Vrms Minimum Isolation Voltage Ì For T1/CEPT/ISDN-PRI Line Interfaces Í Matched to Leading Tranceiver Chips


    Original
    PDF EN41003/EN60950 3000Vrms UL94-V0 PM-IS30 PM-IS31 PM-IS32 PM-IS33 PM-IS34 PM-IS35 PM-IS36

    Untitled

    Abstract: No abstract text available
    Text: DPDT HSMR SERIES 2A FEATURES ・Offers excellent board space savings ・Surge withstand voltage up to 2500V, meets FCC Part 68 and Telecordia ・Meets EN60950/EN41003 ・High contact capacity 2A 30VDC ・SMT and DIP types available ・Single side stable and latching type available


    Original
    PDF EN60950/EN41003 30VDC 125VAC 250VAC/220VDC

    bs6305 -ul1459

    Abstract: BS6305 TLA4529 TLA4529-1 TLA4529-2
    Text: Audio TLA4529 Line Matching Transformer TLA4529 is a 1:1 line matching transformer with the following features. • BABT certified for reinforced insulation to EN41003 & EN60950. . Certificate #: CT/T/0054 • Also conforms to U.S. FCC part 68, Canadian CS 03 and Australian AS3260 regulations.


    Original
    PDF TLA4529 TLA4529 EN41003 EN60950. CT/T/0054 AS3260 BS6305) TLA4529-1 bs6305 -ul1459 BS6305 TLA4529-1 TLA4529-2

    Untitled

    Abstract: No abstract text available
    Text: TYPE 24Z - ISOLATION TRANSFORMERS Dual ISDN S Interface FEATURES Designed for ISDN S/T telecom applications. Meets CCITT 1.430 pulse template. 1500 Vrms, basic insulation per IEC 950:1991, Mod. EN60950:1992 +A1 +A2:1993, EN41003:1990 TUV Bauart certificate # B 95 04 18725 002


    Original
    PDF EN60950 EN41003 24Z489X 24Z4892 24Z4893 24Z4894 24Z4895 24Z4896

    Untitled

    Abstract: No abstract text available
    Text: TYPE 18Z - SINGLE THROUGH-HOLE TRANSFORMERS ISDN-S Interface FEATURES Designed for ISDN S/T telecom applications. Meets CCITT I.430 pulse template. 1500 Vrms, basic insulation per IEC 950:1991, Mod. EN60950:1992 +A1 +A2:1993, EN41003:1990 Picture removed for faster downloading


    Original
    PDF EN60950 EN41003 18Z489X 18Z4893 18Z4894 18Z4895 18Z4896

    Untitled

    Abstract: No abstract text available
    Text: TYPE 24Z - ISOLATION TRANSFORMERS Dual ISDN S Interface FEATURES Designed for ISDN S/T telecom applications. Meets CCITT 1.430 pulse template. 1500 Vrms, basic insulation per IEC 950:1991, Mod. EN60950:1992 +A1 +A2:1993, EN41003:1990 TUV Bauart certificate # B 95 04 18725 002


    Original
    PDF EN60950 EN41003 24Z489X 24Z4892 24Z4893 24Z4894 24Z4895 24Z4896

    24z transistor

    Abstract: EN41003 24Z4892 24Z4893 24Z4894 24Z4895 24Z4896 24Z4897 24Z4898
    Text: TYPE 24Z - ISOLATION TRANSFORMERS Dual ISDN S Interface FEATURES Designed for ISDN S/T telecom applications. Meets CCITT 1.430 pulse template. 1500 Vrms, basic insulation per IEC 950:1991, Mod. EN60950:1992 +A1 +A2:1993, EN41003:1990 TUV Bauart certificate # B 95 04 18725 002


    Original
    PDF EN60950 EN41003 24Z489X 24Z4892 24Z4893 24Z4894 24Z4895 24Z4896 24Z4897 24z transistor 24Z4892 24Z4893 24Z4894 24Z4895 24Z4896 24Z4897 24Z4898

    PE-65389

    Abstract: PE-65566 PE-65835 PE-65831 PE-65415 bs 6301 PE-65830 PE-65832 PE-65834 PE-65837
    Text: T1/CEPT/ISDN-PRI TRANSFORMERS Reinforced Insulation, 3 KVrms Certified for reinforced insulation per EN41003/EN60950 For T1/CEPT line interfaces Matched to leading transceiver ICs Designed to meet ITU-T G.703 Electrical Specifications @ 25°C — Operating Temperature 0°C to 70°C Unless Otherwise Noted


    Original
    PDF EN41003/EN60950 PE-65389 PE-65566 PE-65835 PE-65831 PE-65415 bs 6301 PE-65830 PE-65832 PE-65834 PE-65837

    Untitled

    Abstract: No abstract text available
    Text: TYPE 18Z - SINGLE THROUGH-HOLE TRANSFORMERS ISDN-S Interface FEATURES Designed for ISDN S/T telecom applications. Meets CCITT I.430 pulse template. 1500 Vrms, basic insulation per IEC 950:1991, Mod. EN60950:1992 +A1 +A2:1993, EN41003:1990 TÜV Bauart certificate # B 95 04 18725 002


    Original
    PDF EN60950 EN41003 18Z489X 18Z4893 18Z4894 18Z4895 18Z4896

    H20R1202

    Abstract: EPR1541 EPR1542 EPR1543 EPR1544 EPR1545 EPR1546 EPR1546E
    Text: T1/CEPT Line Interface Transformers ELECTRONICS INC. • Optimizied for Leading Transceiver I.C.’s • • Reinforced Insulation per UL1459 & UL1950, EN41003 & EN60950 • • 3000 Vrms Isolation • • See Selection Guide for I.C. Cross Reference • • Standard Operating Temperature : 0°C to 70°C •


    Original
    PDF UL1459 UL1950, EN41003 EN60950 EPR1546E) EPR1541 EPR1542 EPR1543 EPR1544 EPR1545 H20R1202 EPR1541 EPR1542 EPR1543 EPR1544 EPR1545 EPR1546 EPR1546E

    18Z4893

    Abstract: 18Z4894 18Z4897 18Z4898 18Z4899
    Text: TYPE 18Z - SINGLE THROUGH-HOLE TRANSFORMERS ISDN-S Interface FEATURES Designed for ISDN S/T telecom applications. Meets CCITT I.430 pulse template. 1500 Vrms, basic insulation per IEC 950:1991, Mod. EN60950:1992 +A1 +A2:1993, EN41003:1990 TÜV Bauart certificate # B 95 04 18725 002


    Original
    PDF EN60950 EN41003 18Z489X 18Z4893 18Z4894 18Z4895 18Z4896 18Z4897 18Z4893 18Z4894 18Z4897 18Z4898 18Z4899

    Untitled

    Abstract: No abstract text available
    Text: TYPE 18Z - SINGLE THROUGH-HOLE TRANSFORMERS ISDN-S Interface FEATURES Designed for ISDN S/T telecom applications. Meets CCITT I.430 pulse template. 1500 Vrms, basic insulation per IEC 950:1991, Mod. EN60950:1992 +A1 +A2:1993, EN41003:1990 TÜV Bauart certificate # B 95 04 18725 002


    Original
    PDF EN60950 EN41003 18Z489X 18Z4893 18Z4894 18Z4895 18Z4896 18Z4897

    cr0059

    Abstract: "Critchley Components" Critchley CRITCHLEY transformer Part-5 TBR-21 ETS300
    Text: Critchley Components Limited CRITCHLEY 9025 ISSUE G - 17/08/98 PO Box 246 Queens Drive Industrial Estate Nottingham NG2 1NQ A compact encapsulated line isolating transformer, BABT, UL and BSi certified. Tested and approved in accordance with the requirements of EN41003: 1997, EN60950: 1992 IEC950 , EN60065: 1994 and AS/NZS 3260:1993 (BSi Certificate


    Original
    PDF EN41003: EN60950: IEC950) EN60065: UL1459, UL1950 234-M90 E171368 250mV cr0059 "Critchley Components" Critchley CRITCHLEY transformer Part-5 TBR-21 ETS300

    cr0059

    Abstract: CRITCHLEY* 9005 CRITCHLEY "Critchley Components" critchley 100 Critchley transformers critchley 9005 resistor 220 ETS300 115 986 1126
    Text: Critchley Components Limited CRITCHLEY 9005 ISSUE C - 23/03/98 PO Box 246 Queens Drive Industrial Estate Nottingham NG2 1NQ A compact encapsulated line isolating transformer, BABT, UL and BSi certified. Tested and approved in accordance with the requirements of EN41003: 1997, EN60950: 1992 IEC950 , EN60065: 1994 and AS/NZS 3260:1993 (BSi Certificate


    Original
    PDF EN41003: EN60950: IEC950) EN60065: UL1459, UL1950 234-M90 E171368 EN60950 cr0059 CRITCHLEY* 9005 CRITCHLEY "Critchley Components" critchley 100 Critchley transformers critchley 9005 resistor 220 ETS300 115 986 1126

    TXD2-3V

    Abstract: TXD2-5V
    Text: TX-D HIGH INSULATION RELAYS Conforming to the supplementary insulation class of EN Standards EN41003/EN60950 TX-D RELAYS UL File No.: E43149 CSA File No.: LR26550 • 2,000 V breakdown voltage between contact and coil. contacts ensures high contact reliability.


    OCR Scan
    PDF EN41003/EN60950) E43149 LR26550 TXD2-3V TXD2-5V

    Untitled

    Abstract: No abstract text available
    Text: BXA30 SERIES Single, dual and triple output Recommended for new design-ins • Designed to meet telecom power supply interface standard prETS300-132 ■ Designed to meet EN60950 2nd Ed., UL1950, EN41003, UL1459 2nd ED., CSA950 ■ Internal implementation of VDE0878-A and EN55022-A


    OCR Scan
    PDF BXA30 prETS300-132 EN60950 UL1950, EN41003, UL1459 CSA950 VDE0878-A EN55022-A EN61000-4-2,

    BXA30-12D12

    Abstract: BXA30-48S12-F BXA3048T BXA30-24D15 bxa30-24s05 BXA30 CSA950 EN55022-A EN61000-4-2 VDE0878-A
    Text: BXA30 SERIES Single, dual and triple output Recommended for new design-ins • Designed to meet telecom power supply interface standard prETS300-132 ■ Designed to meet EN60950 2nd Ed., UL1950, EN41003, UL1459 2nd ED., CSA950 ■ Internal implementation of VDE0878-A and EN55022-A


    OCR Scan
    PDF BXA30 prETS300-132 EN60950 UL1950, EN41003, UL1459 CSA950 VDE0878-A EN55022-A EN61000-4-2, BXA30-12D12 BXA30-48S12-F BXA3048T BXA30-24D15 bxa30-24s05 CSA950 EN55022-A EN61000-4-2

    VDE-0871

    Abstract: LXF Series Chemicon International U 420 B BXA30-48S12-F
    Text: ^ 0 SERIES 30 Wait Wîcle Input Telecom DC/DC Converters • Designed to Meet Telecom Power Supply Interface Standards • Designed to meet EN60950 2nd ED, UL1950, EN41003, UL1459 • • • • • Internal Implementation of VDE0871-A and IEC801-2 Fixed Frequency Operation at 350 kHz


    OCR Scan
    PDF EN60950 UL1950, EN41003, UL1459 VDE0871-A IEC801-2 BXA30 2V/15V -12V/15V VDE-0871 LXF Series Chemicon International U 420 B BXA30-48S12-F

    BXA15-24D15

    Abstract: bxa15 48s05
    Text: SERIES Wsde Input Telecom DC/DC Converters a 15 • 3" X 2.4" X 0.5" Package With Standoffs • Designed to Meet EN60950 2nd Edition, UL1950, EN41003, UL1459 2nd Edition • Internal Im plem entation of VDE0871-A and IEC801-2 • Fixed Frequency O peration at 350 kHz


    OCR Scan
    PDF EN60950 UL1950, EN41003, UL1459 VDE0871-A IEC801-2 8-36V 6-75V BXA15 2V/15V BXA15-24D15 48s05

    XA1548

    Abstract: BXA15-24D15
    Text: BXA15 SERIES Single, dual and triple output Recom m ended for new deslgn-lns • Designed to meet telecom power supply interface standard prETS300-132 ■ Designed to meet EN60950 2nd ED, UL1950, EN41003, UL1459 2nd ED., CSA22.2-950 ■ Internal implementation of VDE0878-A and EN55022-A


    OCR Scan
    PDF BXA15 prETS300-132 EN60950 UL1950, EN41003, UL1459 CSA22 VDE0878-A EN55022-A EN61000-4-2, XA1548 BXA15-24D15

    BXA30-48S12-F

    Abstract: BXA30
    Text: BXA30 SERIES Single, dual and triple output R ecom m ended for new design-ins • Designed to meet telecom power supply interface standard prETS300-132 ■ Designed to meet EN60950 2nd Ed., UL1950, EN41003, UL1459 2nd ED., CSA950 ■ Internal implementation of VDE0878-A and EN55022-A


    OCR Scan
    PDF BXA30 prETS300-132 EN60950 UL1950, EN41003, UL1459 CSA950 VDE0878-A EN55022-A EN61000-4-2, BXA30-48S12-F