Untitled
Abstract: No abstract text available
Text: Remote I/O system excom module rack, non-Ex, for 24 modules MT24-N The module rack MT24-3G consists of a backplane and the actual rack system. It can accommodate 2 gateways, 2 power supply units as well as 24 I/O modules. Up to 192 binary in/outputs or 96 analog in/outputs resp. a mix
|
Original
|
MT24-N
MT24-3G
2013-07-14T00
D-45472
STB16-4RS/1
STB16-4RC/1
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom module rack, zone 1, for 16 modules MT18-R024 The MT18-R024 module rack consists of a backplane and the actual rack system. It can accommodate 2 gateways, 2 power supply units as well as 16 I/O modules. Up to 128 binary in/outputs or 64 analog in/outputs resp. a
|
Original
|
MT18-R024
MT18-R024
D-45472
STB16-4RS/1
STB16-4RC/1
2013-07-14T00
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom module rack, zone 2, for 24 modules MT24-3G The module rack MT24-3G consists of a backplane and the actual rack system. It can accommodate 2 gateways, 2 power supply units as well as 24 I/O modules. Up to 192 binary in/outputs or 96 analog in/outputs resp. a mix
|
Original
|
MT24-3G
MT24-3G
mod37
D-45472
STB16-4RS/1
STB16-4RC/1
2013-07-14T00
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom power supply unit, 24 VDC, zone 2 PSM24-3G The PSM24-3G module supplies the excom® system with power to the full extension. The power supply module can be used in zone 2. The PSM24-3G supplies 24 VDC. • DC power module for supply of a fully
|
Original
|
PSM24-3G
PSM24-3G
2013-07-13T18
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom potentiometer module, 4-channel AI43-N The analog input module AI43-N is used for the connection of potentiometers in 3 or 4wire technology. If 3-wire potentiometers are used, the terminals at the module rack have to be bridged. Resistance measurements, hence
|
Original
|
AI43-N
AI43-N
2013-07-13T19
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom output module, analog, 4-channel, HART® AOH40-N The output module AOH40-N is used for connection of intrinsically safe analog actuators such as control valves or process indicators. The outputs are not galvanically separated from each other. When connecting the field
|
Original
|
AOH40-N
AOH40-N
2013-07-13T19
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom System enclosure EG-VA6555/BV680212 • ■ ■ ■ Stainless steel housing with integrated module rack Stainless steel housing with M20 flange plate Integrated filter 1 pcs. and MT18 module rack Cage clamps for the signal connection
|
Original
|
EG-VA6555/BV680212
2013-07-13T19
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom dummy modules for empty slots BM1 • Type code Ident no. BM1 6884036 Housing material Plastic Protection class Ambient temperature Relative humidity Vibration test Shock test EMC IP20 -20…+70 °C ð 95% at 55 °C acc. to EN 60068-2
|
Original
|
2013-07-13T19
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom System enclosure EG-VA6555/BV680111 • ■ ■ ■ Stainless steel housing with integrated module rack Stainless steel housing with M16 flange plate Integrated filter 1 pcs. and MT18 module rack Mini-Combicon terminals for the signal
|
Original
|
EG-VA6555/BV680111
2013-07-13T19
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom Universal module rack for 16 modules MT18-C230 The MT18-C230 module rack consists of a backplane and the actual rack system. It can accommodate 2 gateways, 2 power supply units resp. AC converters as well as 16 I/O modules. Up to 128 binary in/outputs or 64
|
Original
|
MT18-C230
MT18-C230
2013-07-14T00
D-45472
|
PDF
|
IEC 60947-5-6
Abstract: No abstract text available
Text: Remote I/O system excom input module, digital, 4-channel DI40EX The input module DI40Ex is used for the connection of NAMUR sensors DIN EN 60947-5-6 or mechanical contacts. • ■ Input module for intrinsically safe sensors Complete galvanic separation
|
Original
|
DI40EX
DI40Ex
2013-07-13T19
D-45472
IEC 60947-5-6
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom input module, analog, passive, 4-channel, HART® AIH41EX The input module AIH41Ex is designed to connect 4-wire transducers active input = sink mode / transducer active . The module features protection class Ex ib IIC and can be mounted in zone 1 in combination
|
Original
|
AIH41EX
AIH41Ex
2013-07-13T19
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom input module, analog, active, 4-channel, HART® AIH40-N The input module AIH40-NEx is used for the connection of 2-wire transducers active input = source mode / transducer passive . The inputs are not galvanically separated from
|
Original
|
AIH40-N
AIH40-NEx
2013-07-13T19
D-45472
|
PDF
|
profibus
Abstract: No abstract text available
Text: Remote I/O system excom PROFIBUS-DP fiber-optic coupler for zone 1 OC11Ex/2G.2 The optocoupler OC11Ex/2G.2 converts the PROFIBUS-DP signals into optical signals and transmits them safely over long distances via optical fibers from the non-Ex to the Ex area .
|
Original
|
OC11Ex/2G
OC11Ex/3G
RS485-IS
2013-07-13T19
D-45472
profibus
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom converter, 115 VAC PPSA115EX The AC/DC converter PPSA115Ex supplies the excom® system with power to the full extension. A combined protection rating of Exm and Ex-e enables application in zone 1. It is also fully potted and installed in a die-cast aluminium frame.
|
Original
|
PPSA115EX
PPSA115Ex
2013-07-13T19
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom PROFIBUS-DP interface GDP-IS/FW2.1 The GDP-IS gateway serves to connect the excom® system to PROFIBUS-DP networks. Connection to the PROFIBUS-DP can be established via fiber optics or with copper cables. The use of fiber optics requires the connection of a coupler pair between wired and
|
Original
|
RS485-IS
RS485
2013-07-13T19
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom RS485-IS connector, PROFIBUS D9T-RS485IS • ■ Type code Ident no. D9T-RS485IS 6890944 Ex approval acc. to conformity certificate Device designation KEMA 04 ATEX 1233 É II 2 G Ex ib IIC T4 Housing material Plastic Protection class
|
Original
|
RS485-IS
D9T-RS485IS
SC12Ex
OC11Ex/2G!
2013-07-13T19ss
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom converter, 230 VAC PPSA230EX The AC/DC converter PPSA230Ex supplies the excom® system with power to the full extension. A combined protection rating of Exm and Ex-e enables application in zone 1. It is also fully potted and installed in a die-cast aluminium frame.
|
Original
|
PPSA230EX
PPSA230Ex
2013-07-13T19
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom System enclosure EG-VA6555/BV680211 • ■ ■ ■ Stainless steel housing with integrated module rack Stainless steel housing with M16 flange plate Integrated filter 1 pcs. and MT18 module rack Cage clamps for the signal connection
|
Original
|
EG-VA6555/BV680211
2013-07-13T19
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom System enclosure EG-VA4055/BV681212 • ■ ■ ■ Stainless steel housing with integrated module rack Stainless steel housing with M20 flange plate Integrated filter 1 pcs. and MT9 module rack Cage clamps for the signal connection
|
Original
|
EG-VA4055/BV681212
2013-07-13T19
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom System enclosure EG-VA6555/BV680112 • ■ ■ ■ Stainless steel housing with integrated module rack Stainless steel housing with M20 flange plate Integrated filter 1 pcs. and MT18 module rack Mini-Combicon terminals for the signal
|
Original
|
EG-VA6555/BV680112
2013-07-13T19
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Remote I/O system excom System enclosure EG-VA4055/BV681211 • ■ ■ ■ Stainless steel housing with integrated module rack Stainless steel housing with M16 flange plate Integrated filter 1 pcs. and MT9 module rack Cage clamps for the signal connection
|
Original
|
EG-VA4055/BV681211
2013-07-13T19
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: POSITIVE ECL FULL SIZE DIP CRYSTAL OSCILLATORS ACPE Series FEATURES: * High Frequency Range * Positive ECL with + 5V or * 5.2 V operation * Compiementatry Output Option * Low output Impedance * Excolent Noise Margin * Hermeticaty seated package STANDARD SPECIFICATIONS
|
OCR Scan
|
50ppm
25ppm
ACPE3-50
000MHZ-B-C-S-G
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Ipizt r□nl[= c omp an e > nt 4 3 9 C o m m e rc e Lane * W e s t Berlin, M ew Jersey 08091 B5G> 3 3 5 -2 2 7 7 * FAX (8 5 6 3 3 5 -7 2 2 3 safes com p excorp, com * w w w .c o m p e x c o rp .c o m
|
OCR Scan
|
|
PDF
|