Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    GAS TRIODE Search Results

    GAS TRIODE Result Highlights (1)

    Part ECAD Model Manufacturer Description Download Buy
    P104 Coilcraft Inc Silicon Controlled Rectifier, Visit Coilcraft Inc

    GAS TRIODE Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    CV3524

    Abstract: cold cathode light sensitive trigger circuit Application 1955 BY100
    Text: Ref.: G1/236G Sub-M iniature Cold Cathode Gas-Filled Triode Code: G1/236G CV3524 The G1/236G is a three electrode, gas-filled cold cathode triode. It has been designed prim arily for “ storage ” purposes in telephone circuits but has applications in the field of electronic counting.


    OCR Scan
    G1/236G CV3524) G1/236G GI/236G G1/236Gâ CV3524 cold cathode light sensitive trigger circuit Application 1955 BY100 PDF

    CV413

    Abstract: g150-2d G150/2D 19S8
    Text: Ref.: G150/2D Cold-Cathode Gas-Filled Triode Code: G150/2D CV4I3 T h e G 1 50/ 2D cold cathode, gas-filled t rio d e has an activated cathode g iv in g a lo w m aintaining voltage, to g e th e r w ith a go o d life perform ance. M E C H A N IC A L D A T A


    OCR Scan
    G150/2D G150/2D CV413) G150/2Dâ CV413 g150-2d 19S8 PDF

    CV2174

    Abstract: G240
    Text: Ref.: G 240/2D Cold-Cathode Gas-Filled Triode Code: G240 2D CV2174 T h e G 2 40/ 2D is a cold-cathode, th re e electrode, gas-filled triode. It has been de ve lo pe d fo r use in ap plications w h e re a h igh e r p o w e r is needed in th e an o d e c ircu it than is obtain ab le w ith the G 150/2D


    OCR Scan
    G240/2D CV2174) G240/2D G150/2D G240/2Dâ CV2174 G240 PDF

    Untitled

    Abstract: No abstract text available
    Text: ENGAGE. ENABLE. EXCEL. www.excelitas.com HY-32 Deuterium Triode Thyratron Description The HY-32 is a deuterium-illed, triode thyratron. The deuterium ill gas facilitates reliable operation at higher voltages and low to moderate repetition rates compared to similar


    Original
    HY-32 HY-32 PDF

    Untitled

    Abstract: No abstract text available
    Text: ENGAGE. ENABLE. EXCEL. www.excelitas.com HY-11 Hydrogen Filled Triode Thyratron Description The HY-11 is a hydrogen-illed, triode thyratron. The hydrogen gas ill facilitates reliable operation at a lower to moderate voltage and very high pulse repetition rates when compared


    Original
    HY-11 HY-11 PDF

    EC50 triode

    Abstract: GAS TRIODE EC50
    Text: Milliard EC50 GAS TRIODE Heater Capacities Vf If Cak Cgk Cag « » = = 6.3 V 1.3 A 3.8 uuF 6.1 uuF 2.7 uuF Operating Conditions V max peak between any two electrodes . 7a max (peak) . la max (average) . la max (peak) .


    OCR Scan
    PDF

    IGNITOR Z 400 M

    Abstract: 67551 Thyratron Ignitron PL6755 Scans-00180016 thyratron tube rs tube scans-0018001 redresseur
    Text: PHILIPS PL 6755 THYRATRON, mercury-vapour and inert gas-rilled, triode THYRATRON, triode à vapeur de mercure et à gaz rare STROMTORRÖHRE, Triode mit Quecksilberdampf- und Edelga? füllung Application: A. Dimming Installations for stage-lighting, fluorescent lighting etc.


    OCR Scan
    PL6755 IGNITOR Z 400 M 67551 Thyratron Ignitron PL6755 Scans-00180016 thyratron tube rs tube scans-0018001 redresseur PDF

    Mullard

    Abstract: GAS TRIODE
    Text: GT4A Mallard GAS TRIODE Heater Tf If Capacities Cak Cgk Cag • = = «= 4.0 V 1.2 V 3.1 uuF *— 3.4 uuF"»=— 2.7 uuF «— Operating Conditions V max peak between any two electrodes Va max (peak) . la max (peak) .


    OCR Scan
    PDF

    c 939

    Abstract: 3c23 PL3C23 valeo thyratron
    Text: PH ILIPS PL 3C23 THYRATRON; mercury vapour and inert gas filled triode with negative oontrol characteristic THYRATRON; triode à remplissage de vapeur de mercure et de gaz inerte avec caractéristique de commande négative STROMTORRÖHRE; quecksilberdampf- und edelgasgefüllte Triode


    OCR Scan
    7R30340 PL3C23 7R303A4 c 939 3c23 PL3C23 valeo thyratron PDF

    Thyratron HY 10 R

    Abstract: Thyratron HY-3002 thyratron tube Thyratron recovery time thyratron tube operation deuterium gas discharge tube application PerkinElmer trigger hy30
    Text: Imaging D A T A S H E E T Lighting Telecom Thyratrons HY-3002 Hydrogen Thyratron Description A TYPICAL OPERATING CONDITION Note 11 The HY-3002 is a hydrogen-filled, triode thyratron. The hydrogen gas fill facilitates reliable operation at a moderately-high


    Original
    HY-3002 HY-3002 DS-198 Thyratron HY 10 R Thyratron thyratron tube Thyratron recovery time thyratron tube operation deuterium gas discharge tube application PerkinElmer trigger hy30 PDF

    HY-3003

    Abstract: Thyratron Thyratron recovery time Thyratron HY 10 R thyratron tube operation thyratrons
    Text: Imaging D A T A S H E E T Lighting Telecom Thyratrons HY-3003 Deuterium Thyratron Description A TYPICAL OPERATING CONDITION Note 11 The HY-3003 is a deuterium-filled, triode thyratron. The deuterium gas fill facilitates reliable operation at a higher voltage and


    Original
    HY-3003 HY-3003 DS-200 Thyratron Thyratron recovery time Thyratron HY 10 R thyratron tube operation thyratrons PDF

    3-500Z

    Abstract: 3-500z tube amperex transmitting IL60147 "Power Triode" amperex amperex aml9-1 500w class d amplifier 500w class d audio amplifier GAS TRIODE
    Text: 3-500Z Amperex High-MU Power Triode • Heavy Graphite anode for high interm ittent overload capabilities. • A Zirconium coated anode to absorb gas for longer life. G ENERAL D A T A "*'1 Electrical: Filament-Thoriated Tungsten Voltage Current, at 5.0 volts


    OCR Scan
    3-500Z 3-500Z 3-500z tube amperex transmitting IL60147 "Power Triode" amperex amperex aml9-1 500w class d amplifier 500w class d audio amplifier GAS TRIODE PDF

    anode clip

    Abstract: socket 939 PL10 3554
    Text: PHILIPS GAS-FILLED TRIODE with high insulated external grid for use in pulse and relay circuits TRIODE A REMPLISSAGE DE GAZ avec grille extérieur h grande résistance d'isolation pour utilisation en circuits d ’impulsions et de relais GASGEFÜLLTE TRIODE mit hochisoliertem äusserem Git­


    OCR Scan
    7R30239 anode clip socket 939 PL10 3554 PDF

    Untitled

    Abstract: No abstract text available
    Text: HY-3002/5948A-Replacement Hydrogen Filled Triode Thyratron NOTE The HY3002/5948A-REPLACEMENT The HY-3002 is a hydrogen-illed, triode thyratron. The hydrogen gas ill facilitates reliable operation is a HY3002 that incorporates a base at a moderately-high voltage and very high pulse repetition rates when compared to similar


    Original
    HY-3002/5948A-Replacement HY3002/5948A-REPLACEMENT HY-3002 HY3002 HY3002/5948AREPLACEMENT HY-3002/5984A-Replacement PDF

    rk61 thyratron tube

    Abstract: Raytheon RK61 "regenerative receiver" GAS TRIODE RK61 Thyratron SUBMINIATURE THYRATRON RAYTHEON thyratron tube operation Raytheon Company
    Text: TECHNICAL INFORMATION SUBMINIATURE GAS TRIODE TYPE ^ l¿ _ e _ Z Z Z y L - < r 7 i — RK61 The RK61 is a small size 3-elem ent thyratron useful in applications requiring extreme economy of space, weight, and battery drain. It is designed for use as a self-quenching super-regenerative


    OCR Scan
    PDF

    Thyratron

    Abstract: XR1-6400 GAS TRIODE mullard scans-0018100 XR1 6400
    Text: T R IO D E T H Y R A T R O N 6,4.4 inert gas-filled triode thyratron with negative control characteristic. Primarily designed for motor control applications. XR1-6400 ' ' This data sheet should be read in conjunction with “ D E F IN IT IO N S A N D O P E R A T IO N A L


    OCR Scan
    XR1-6400 MT5545) XR1-6400 Thyratron GAS TRIODE mullard scans-0018100 XR1 6400 PDF

    GAS TRIODE

    Abstract: CK7979 RAYTHEON Raytheon Company
    Text: Teclinicstl CK7979 Information TEC H NICA L INFORM ATION SERVICE SUBMINIATURE GAS TRIODE MECHANICAL DATA The C K7979 is a g rid c o n tro lle d neon fille d trio d e of su b m in ia tu re c o n s tru c tio n . It has a d ir e c tly E N V E L O P E .T - 2 G lass


    OCR Scan
    CK7979 CK7979 GAS TRIODE RAYTHEON Raytheon Company PDF

    rca tube 80

    Abstract: RCA tube RADIOTRON rca company JAMP
    Text: GAS-TRIODE C O L D -C A T H O D E G L O W -D IS C H A R G E T Y P E Maximum Overall Length 2 -5/8” Maximum Seated Height 2-1/16” Maximum Diameter 1-5/16" Bulb ^ T-9 Base n /^ t\ Intermed.Sh.Octal 6-Pin Pin 1 -N o Connection P 'n 7 — Grid Pin 2 -Cathode


    OCR Scan
    92C-64I9RI 92C-6420 92C-6419R1 92C-6420 rca tube 80 RCA tube RADIOTRON rca company JAMP PDF

    MCMurdo

    Abstract: MCMurdo valve
    Text: Gl/HIK TYPE G 1/37IK HIGH SPEED PRIMED-TRIGGER COLD-CATHODE TUBE The G1/371K is a high-speed primed-trigger tube developed for use w ith the G10/241E Unidirectional Cold-Cathode Gas Filled Decade C o un ter fo r which a single cathode trigger tube is required as a coupling elem ent between tubes.


    OCR Scan
    G1/37IK G1/371K G10/241E MCMurdo MCMurdo valve PDF

    light sensitive trigger circuit Application

    Abstract: ionisation cold cathode G400 BY100
    Text: 6400/IK C l/ M TYPE G 400/IK HIGH VOLTAGE COLD CATHODE VOLTAGE STABILISER The G400/1 K is a miniature low current, high voltage gas-filled stabiliser specially developed for use w here a high degree of stability is required. C H A R A C T E R IS T IC S 400


    OCR Scan
    C400/IK G400/IK G400/1 GI/236G G1/236G /236G light sensitive trigger circuit Application ionisation cold cathode G400 BY100 PDF

    Thyratron

    Abstract: ME1502 Mullard i-089
    Text: T R IO D E T H Y R A T R O N ANI T riode inert-gas-filled thyratron with negative control ch a racteristic. P rim a rily d esigne d for in d u strial control applications. " • IO N S A N D , preceding This data sheet should be read in conjunction wi


    OCR Scan
    ME1502) 200mA Thyratron ME1502 Mullard i-089 PDF

    GAS TRIODE

    Abstract: ST12 Scans-0017381
    Text: DU MONT GAS TRIODES Typ es 2B4 an d 6 Q 5 G M ech an ical D im ensions, B asing , an d A v e ra g e O p e ra tin g C h a racte ristics T h e T y p e s 2B 4 and 6Q 5G G a s T riod es are intended for use in D u M ont Cathode-ray O scillographs for sw eep oscillator service. T h ey are also designed for ap plication s where


    OCR Scan
    Interel00 GAS TRIODE ST12 Scans-0017381 PDF

    Raytheon Company

    Abstract: RAYTHEON GAS TRIODE NE-2 neon CK1050A raytheon transistor lamp ne2
    Text: Technical Infox'ma.tioxi TECHNICAL INFORMATION SERVICE CK1050A SUBMINIATURE GAS TRIODE MECHANICAL DATA The C K 1050A is a g rid c o n tro lle d neon f ille d trio d e of su b m in ia tu re c o n s tru c tio n . It has a d ir e c tly heated cathode and is d e sig ned for use e ith e r as an in d ic a to r lamp or a low current ne g a tive g rid


    OCR Scan
    CK1050A CK1050A Raytheon Company RAYTHEON GAS TRIODE NE-2 neon raytheon transistor lamp ne2 PDF

    2A4G

    Abstract: RADIOTRON 2a4 triode ST-12 rca company Scans-0017379
    Text: 2A4-G GAS-TRIODE H Q T -C A T H O D E C O N T R O L - G R ID T Y P E F ila m e n t V o lt a g e * C u rre n t Maximum O v e r a ll Length Maximum Seated H e ig h t Maximum Diam eter Bui b Base P in 1 - N o C o n n e ctio n P in 2 - Fi 1ciment + P in 3 - P la te


    OCR Scan
    ST-12 2A4G RADIOTRON 2a4 triode ST-12 rca company Scans-0017379 PDF