    Part ECAD Model Manufacturer Description Download Buy
    DMT1-180-1.5L Coilcraft Inc General Purpose Inductor, 180uH, 1 Element, ROHS COMPLIANT Visit Coilcraft Inc
    SER2011-801 Coilcraft Inc Power inductor, high current, 10% tol, SMT, RoHS Visit Coilcraft Inc
    SER2011-801ML Coilcraft Inc Power inductor, high current, 10% tol, SMT, RoHS Visit Coilcraft Inc
    SER2011-801MLB Coilcraft Inc General Purpose Inductor, 0.8uH, 20%, 1 Element, Ferrite-Core, SMD, 7674, ROHS COMPLIANT Visit Coilcraft Inc
    SER2011-801MLD Coilcraft Inc General Purpose Inductor, 0.8uH, 20%, 1 Element, Ferrite-Core, SMD, 7674, ROHS COMPLIANT Visit Coilcraft Inc

    ISO 11801 ACR Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: HARTING Industrial Cable 8-wire Cat. 7 PUR Industrial Cable 8-wire, Cat. 7, PUR Advantages General Suitable for generic cabling Category 7 / Class F according ISO/IEC 11801 respectively EN 50173-1 especially for fixed installation Qualified for transmission up to


    Original
    10GigaBit 10GBase-T IEEE802 AWG23/1 600MHz PDF

    Untitled

    Abstract: No abstract text available
    Text: HARTING Han 24 HPR Industrial enlarged Cable 8-wire, Cat. 5, PUR Industrial Cable 8-wire, Cat. 5, PUR Advantages General • Suitable for generic cabling Category 5 / Class D according ISO/IEC 11801 respectively EN 50173-1 especially for flexible installation patch cords


    Original
    1000Base-T IEEE802 26/7AWG 100MHz E96807 D-32339 D-32328 PDF

    s2yy

    Abstract: RS625 utp cat 5e 25x2x05 5PVC
    Text: RS_625_6726_900222.doc 17.06.2006 page 1 of 2 RS 625-6726 - 25x2x0.52 AWG 24 S-2YY/H 25 Pair UTP Cat. 5e PVC Application IEEE 802.3: 10Base-T; 100Base-T; ISDN; xDSL IEEE 802.5 16 MB; ISDN; TPDDI; ATM155Mbit/s Standards EN 50173, ISO/IEC 11801 Flame resistance


    Original
    25x2x0 10Base-T; 100Base-T; ATM155Mbit/s AWG24) 900222VA0000RS0250 s2yy RS625 utp cat 5e 25x2x05 5PVC PDF

    Untitled

    Abstract: No abstract text available
    Text: Technical specification: A Rated voltage: IEC 61076-2-109 48 V Current rating: IEC 61076-2-109 500 mA at 40°C Transmission properties: 10 Gigabit Ethernet CAT6 ISO IEC 11801 Ø16,5 Ω Ø14 M12x1 L 3 3 Sealing Casing wall 12 10 Width across flats 15 Width across flats14


    Original
    M12x1 60512-9a flats14 Co04x45Â 2002/95/EC M12x1 43K1A1477 PDF

    S2YY

    Abstract: utp cat 5e RS625 bcore
    Text: RS_625_6732_900223.doc 17.06.2006 page 1 of 2 RS 625-6732 - 25x2x0.52 AWG 24 S-2YY/H 25 Pair UTP Cat. 5e LSOH Application IEEE 802.3: 10Base-T; 100Base-T; ISDN; xDSL IEEE 802.5 16 MB; ISDN; TPDDI; ATM155Mbit/s Standards EN 50173, ISO/IEC 11801 Flame resistance


    Original
    25x2x0 10Base-T; 100Base-T; ATM155Mbit/s AWG24) 900223VA0000RS0250 S2YY utp cat 5e RS625 bcore PDF

    Panduit utp cable

    Abstract: TX6500 DP24688TP CJ688TP DP12688TP UTPSP10 DP48688TP TX6500TM DP96688TP
    Text: TX6500 Category 6 PLUS UTP Cable SPECIFICATION SHEET specifications Category 6 PLUS Cable shall far exceed ANSI/TIA/EIA-568-B.2-1 Category 6 and ISO/IEC 11801 Class E standards. The conductors shall be 23 AWG construction with FEP plenum or polyethylene (non-plenum)


    Original
    TX6500 ANSI/TIA/EIA-568-B PUR6504BU-U PUR6504WH-U PUP6504BU-U PUP6504WH-U SA-COSP27 Panduit utp cable DP24688TP CJ688TP DP12688TP UTPSP10 DP48688TP TX6500TM DP96688TP PDF

    E138034

    Abstract: 219513-X Cat5e current CMP 3.48 UL-910 AMP EIA-568-B standard
    Text: Category 5e UTP Cable, 200MHz 219513-X, 219538-X Ripcord Conductor Insulation Core: 4-Pairs, Cabled Together Pairs: Twisted with Different Lays Jacket Nominal Diameter Description AMP NETCONNECT Enhanced Category 5 Cat5e cables exceed TIA/EIA-568-B.2 Enhanced Category 5 (Category 5e) and ISO/IEC 11801 Class


    Original
    200MHz 219513-X, 219538-X TIA/EIA-568-B 1000BASE-Tx) 100BASE-Tx, 200MHZ /100m 300VAC 25ns/100m E138034 219513-X Cat5e current CMP 3.48 UL-910 AMP EIA-568-B standard PDF

    ISO 11801 cat-5e

    Abstract: UTP cat 6 cable DCD10713-00500DP RAL5012 100N DCD10709-00500DP DCD10710-00500DP DCD10711-00500DP IEC61156-6 UTP Cat 6
    Text: 07.04.2006 Page 1 of 2 CAT 5E U/UTP Patch Unscreened Twisted Pair 125MHz Application Generic cabling systems. Patch and work area cable Standards EN 50173-1; ISO/IEC 11801; EN 50288-3-2; IEC61156-6; Fire rating PVC LSOH : IEC 60332-1 : IEC 60754-2; IEC 61034, IEC 60332-1


    Original
    125MHz IEC61156-6; RAL7035 DCD10707-00500DP RAL3018 DCD10708-00500DP RAL6018 DCD10709-00500DP RAL1018 DCD10710-00500DP ISO 11801 cat-5e UTP cat 6 cable DCD10713-00500DP RAL5012 100N DCD10709-00500DP DCD10710-00500DP DCD10711-00500DP IEC61156-6 UTP Cat 6 PDF

    DRAKA

    Abstract: 100N DCD10709-00500DP DCD10710-00500DP DCD10711-00500DP DCD10713-00500DP IEC61156-6 RAL7035 UTP cat 6 cable DCD10707-00500DP
    Text: 07.04.2006 Page 1 of 2 CAT 5E U/UTP Patch Unscreened Twisted Pair 125MHz Application Generic cabling systems. Patch and work area cable Standards EN 50173-1; ISO/IEC 11801; EN 50288-3-2; IEC61156-6; Fire rating PVC LSOH : IEC 60332-1 : IEC 60754-2; IEC 61034, IEC 60332-1


    Original
    125MHz IEC61156-6; RAL3018 DCD10708-00500DP RAL6018 DCD10709-00500DP RAL1018 DCD10710-00500DP RAL5012 DCD10711-00500DP DRAKA 100N DCD10709-00500DP DCD10710-00500DP DCD10711-00500DP DCD10713-00500DP IEC61156-6 RAL7035 UTP cat 6 cable DCD10707-00500DP PDF

    ISO 11801 cat5

    Abstract: RAL9005 43064 2633 011 code 2620
    Text: Product Datasheet P/N - 43064 Rev.3B Page 1 of 2 Date 01-08-2001 Belden 1868E FLEX CAT5 FTP PVC Application • • Horizontal Patch Cable Support current Category 5 applications, such as: 10 Base-T, 100 Base-T, FDDI, ATM Standards • General standards: ISO/IEC 11801, EN 50173, TIA/EIA 568-A


    Original
    1868E ISO 11801 cat5 RAL9005 43064 2633 011 code 2620 PDF

    DRAKA

    Abstract: ISO 11801 cat-5e 100N DCD10709-00500DP DCD10710-00500DP DCD10711-00500DP DCD10713-00500DP IEC61156-6
    Text: 07.04.2006 Page 1 o f 2 CAT 5E U/UTP Patch Uns c re e ne d Twis te d Pair 125MHz Applic atio n Generic cabling systems. Patch and work area cable S tandards EN 50173-1; ISO/IEC 11801; EN 50288-3-2; IEC61156-6; Fire rating PVC LSOH : IEC 60332-1 : IEC 60754-2; IEC 61034, IEC 60332-1


    Original
    125MHz IEC61156-6; Tem551 RAL3018 DCD10708-00500DP RAL6018 DCD10709-00500DP RAL1018 DCD10710-00500DP RAL5012 DRAKA ISO 11801 cat-5e 100N DCD10709-00500DP DCD10710-00500DP DCD10711-00500DP DCD10713-00500DP IEC61156-6 PDF

    1901551-1

    Abstract: IEC 60603-7 vibration
    Text: 108-2479 Product Specification 7 June 13 Rev B SL Series Jacks, Category 5e 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, Category 5e SL Jacks used to provide a universal connection interface between premise wiring of an


    Original
    PDF

    1901551-1

    Abstract: IEC 60603-7 vibration
    Text: 108-131000 Product Specification 7 June 13 Rev B SL Series Jacks, Category 6 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, Category 6 SL Jacks used to provide a universal connection interface between premise wiring of an office


    Original
    PDF

    ISO 11801 2.2

    Abstract: ISO 11801 acr 959385-1 60603-7-1 ISO 11801 IEC 60603-7-5 61935
    Text: 108-22140 Product Specification 16/Nov/2007 Rev G CATEGORY 6 DIN TELECOMMUNICATIONS OUTLET: AMP-TWIST-6S 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for CATEGORY 6 DIN TELECOMMUNICATIONS OUTLET AMP NETCONNECT* AMP-TWIST*-6S used to connect building wiring


    Original
    16/Nov/2007 INGF-070 ISO 11801 2.2 ISO 11801 acr 959385-1 60603-7-1 ISO 11801 IEC 60603-7-5 61935 PDF

    60603-7-X

    Abstract: 61935
    Text: Product Specification 108-93041 13/Oct/2009 Rev B Class E Consolidation Point cable assemblies 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT* Class E Consolidation Points cable assemblies used to connect building wiring for data and


    Original
    13/Oct/2009 INGF-070 60603-7-X 61935 PDF

    ISO 11801 acr

    Abstract: 61935 ISO 11801 2.2 93018 ISO/IEC 11801 60603-7-X
    Text: Product Specification 108-93030 05/Oct/2009 Rev B Class D Consolidation Point cable assemblies 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT* Class D Consolidation points cable assemblies used to connect building wiring for data and


    Original
    05/Oct/2009 INGF-070 ISO 11801 acr 61935 ISO 11801 2.2 93018 ISO/IEC 11801 60603-7-X PDF

    60603-7-X

    Abstract: ISO 11801 2.2
    Text: Product Specification 108-93017 13/Oct/2009 Rev D Cat 6 Unshielded Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT* Cat 6 unshielded patch cord assemblies used to connect building wiring for data and voice


    Original
    13/Oct/2009 INGF-070 60603-7-X ISO 11801 2.2 PDF

    IEC 60332.1-2

    Abstract: IEC 60603-7-5 ISO 11801 acr 61935 60603-7-X IEC 60512-4-1
    Text: 108-93017 Product Specification 23/Nov/06 Rev. A CAT 6 UNSHIELDED PATCH CORDS 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for NETCONNECT Cat 6 unshielded patch cord assemblies used to connect building wiring for data and voice networking systems.


    Original
    23/Nov/06 ING-028 IEC 60332.1-2 IEC 60603-7-5 ISO 11801 acr 61935 60603-7-X IEC 60512-4-1 PDF

    Untitled

    Abstract: No abstract text available
    Text: TX5500 Shielded Cable – S/FTP SPECIFICATION SHEET specifications The S/FTP shielded cable shall be constructed of 4-pair insulated 24 AWG conductors. The twisted pairs shall be wrapped in an overall metallic foil with an overall braid within a LSZH


    Original
    TX5500 PSFL5504DG-ED PSFL5504LG-ED TIA/EIA-568-B NCSP19 WW-NCSP19 PDF

    Untitled

    Abstract: No abstract text available
    Text: Copper components The structured DIGITUS cabling system Different applications, data, speech and video-multimedia ran on different transmission paths in past. This meant multiple installations to do justice to the requirements. The development up to structured cabling has created uniform cabling in the building


    Original
    DK-127014 DK-127015 26-pin SFF-8088) 36-pin SFF-8087) SFF-8088 SFF-8087 PDF

    stpc2mbbl

    Abstract: No abstract text available
    Text: M INI -C OM ® TX5e Shielded Jack Module SPECIFICATION SHEET specifications Eight-position jack module shall terminate 4 pair 22-26 AWG 100 ohm shielded twisted pair cable and shall not require the use of a punchdown tool. Jack module shall use forward motion termination to optimize


    Original
    T568A T568B TX5500 CJS5E88TG COSP36 WW-COSP36 stpc2mbbl PDF

    1633ENH

    Abstract: 11801 ftp cat5e 50C24 ISO 11801 acr 11801
    Text: Product Datasheet P/N - 43133 Rev.3A Page 1 of 2 Date 01-05-2001 Belden 1633ENH CAT 5 enhanced FTP FRNC Application • • Horizontal and building backbone cable. Support current Category 5 and Category 5 enhanced applications, such as: 10 Base-T, 100 Base-T, 1000 Base-T Gigabit Ethernet , FDDI, ATM


    Original
    1633ENH 1633ENH AWG24 11801 ftp cat5e 50C24 ISO 11801 acr 11801 PDF

    iec 60304

    Abstract: STP CAT5e Belden STP STP CAT5e 4pr IEC 11801 EN50173 ISO 11801 colour code 7032 1633ENS
    Text: 1633ENS Cat 5e STP Foil + Braid LSNH Rev 07.09.2004 Application • • Horizontal and building backbone cable. Support current and future Category 5 enhanced applications, such as: 100 Base TX, 100 Base VG AnyLan, 155 ATM and 1000 Base-T (Gibabit Ethernet), FDDI.


    Original
    1633ENS 568-b 1633ENS AWG24 EN50173 1000m iec 60304 STP CAT5e Belden STP STP CAT5e 4pr IEC 11801 EN50173 ISO 11801 colour code 7032 PDF

    ISO 11801 acr

    Abstract: 11801 ftp cat5e 1633E EN 50173 50C24
    Text: Product Datasheet P/N - 43132 Rev.3A Page 1 of 2 Date 01-05-2001 Belden 1633E CAT 5 enhanced FTP PVC Application • • Horizontal and building backbone cable. Support current Category 5 and Category 5 enhanced applications, such as: 10 Base-T, 100 Base-T, 1000 Base-T Gigabit Ethernet , FDDI, ATM


    Original
    1633E 1633E AWG24 ISO 11801 acr 11801 ftp cat5e EN 50173 50C24 PDF