Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LCR COMPONENTS Search Results

    LCR COMPONENTS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    GCM033C70J104KE02J Murata Manufacturing Co Ltd 0201 (0603M) X7S (EIA) 6.3Vdc 0.1μF±10% Visit Murata Manufacturing Co Ltd
    GRT155R61A106ME13J Murata Manufacturing Co Ltd 0402 (1005M) X5R (EIA) 10Vdc 10μF±20% Visit Murata Manufacturing Co Ltd
    GRT21BD72A225KE13K Murata Manufacturing Co Ltd 0805 (2012M) X7T (EIA) 100Vdc 2.2μF±10% Visit Murata Manufacturing Co Ltd
    KC355QD7LF224KH01K Murata Manufacturing Co Ltd X7T (EIA) 1000Vdc 0.22μF±10% Visit Murata Manufacturing Co Ltd
    KC355WD7LG274MH01K Murata Manufacturing Co Ltd X7T (EIA) 1250Vdc 0.27μF±20% Visit Murata Manufacturing Co Ltd

    LCR COMPONENTS Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    U1732A

    Abstract: CAL 3300 6LR61 U1731A 8888H U1782A U1700
    Text: Agilent U1700 Series Handheld LCR Meters Data Sheet Test passive components conveniently, affordably and reliably with the Agilent U1700 Series LCR meters — extending the tradition of industry-leading benchtop units Agilent U1700 Series handheld LCR meters


    Original
    U1700 U1732A/U1732B) range888 5990-3458EN U1732A CAL 3300 6LR61 U1731A 8888H U1782A PDF

    Untitled

    Abstract: No abstract text available
    Text: Agilent U1700 Series Handheld LCR Meters Data Sheet Test passive components conveniently, affordably and reliably with the Agilent U1700 Series LCR meters — extending the tradition of industry-leading benchtop units Agilent U1700 Series handheld LCR meters


    Original
    U1700 U1732A/U1732B) LC888 5990-3458EN PDF

    7476

    Abstract: 7476 datasheet 7476 data sheet osaka APPLICATION NOTES 7476 datasheet of 7476 nihon LCR Components
    Text: Philips Components - Distributors Asia Pacific China Nihon LCR Co.,Ltd, Hong Kong Tel:+852-2957-1721, Fax:+852-2377-4497 Japan Nihon LCR Co.,Ltd, Tokyo head office Tel:+81-3-3251-7181, Fax:+81-3-3257-1483 Nihon LCR Co.,Ltd, Osaka Tel:+81-6-202-1761, Fax:+81-6-202-1760


    Original
    Sa-92-451-6417 7476 7476 datasheet 7476 data sheet osaka APPLICATION NOTES 7476 datasheet of 7476 nihon LCR Components PDF

    IEC479-1

    Abstract: circuit diagram for cd 6283 cd 6283 cs resistencia 1k capacitor LCR meter QAE 21.2 serial to paralelo Circuitos smd jxp HZ55LX
    Text: Models 885 & 886 LCR METER OPERATING MANUAL MANUAL DE INSTRUCCIÓNES MEDIDOR LCR Modelos 885 & 886 Contents 1. INTRODUCTION .1 1.1 GENERAL. 1


    Original
    v092711 IEC479-1 circuit diagram for cd 6283 cd 6283 cs resistencia 1k capacitor LCR meter QAE 21.2 serial to paralelo Circuitos smd jxp HZ55LX PDF

    agilent 4263B

    Abstract: 4263B ic for lcr meter testing capacitors using a meter gpib ic transformer test 16089A 16089E precision instrument transformer capacitance meter service manual
    Text: Agilent 4263B LCR Meter 100 Hz to 100 kHz Technical Overview Introduction The Agilent Technologies LCR meter makes fast measurements on components. It is optimized for applications that require precision and versatility. The instrument's performance ranges


    Original
    4263B 5964-6181E agilent 4263B ic for lcr meter testing capacitors using a meter gpib ic transformer test 16089A 16089E precision instrument transformer capacitance meter service manual PDF

    Untitled

    Abstract: No abstract text available
    Text: Agilent U1730C Series Handheld LCR Meters Take your expectations higher with the latest LCR meters Data Sheet Agilent’s U1730C Series handheld LCR meters allow you to measure at frequencies as high as 100 kHz—a capability typically found only in benchtop meters. Get measurements done faster


    Original
    U1730C 5990-7778EN PDF

    Untitled

    Abstract: No abstract text available
    Text: Models 878A & 879 LCR Multimeters Data Sheet Model 878A Dual Display Auto Ranging LCR Meter Model 879 Deluxe Dual Display Auto Ranging LCR Meter The 878A and 879 measure capacitance, resistance of non-inductive components and inductance. Components can be measured with selectable test frequencies in series or parallel modes as desired. The 4 1/2 digit main LCD displays values to 19,999, and the secondary


    Original
    100Hz, 120Hz, 10KHz 100Hz 10KHz 12Vmin 15Vmax. A/250V PDF

    Sigma AS 226 manual

    Abstract: circuit and working lcr meter BIN13 capacitor LCR meter 16195B 16196U-010 16196B-710
    Text: Agilent 4287A RF LCR Meter 1 MHz - 3 GHz Technical Overview High-Speed RF LCR Meter Anticipating Next Generation Test Needs The Agilent 4287A is a high performance RF LCR meter best fit to production line testing of devices such as SMD inductors and EMI filters, where impedance testing at high frequencies is required.


    Original
    5968-5443E Sigma AS 226 manual circuit and working lcr meter BIN13 capacitor LCR meter 16195B 16196U-010 16196B-710 PDF

    esr meter

    Abstract: Digital Frequency Meter with LCD Display lcr meter circuit LCR Components capacitors ESR Tester capacitor LCR meter digital capacitance meter Capacitor 0.25 uF LCR TL08C 830C
    Text: 49-2012:QuarkCatalogTempNew 9/20/12 1:18 PM Page 49 1 Component Test Equipment TEST & MEASUREMENT Digital LCR Meters Model 878B and 879B Hand-Held LCR Meters Models 885 10 kHz and 886 (100 kHz) Synthesized In-Circuit LCR/ESR Meter B&K Precision’s 878B and 879B 40,000 count L/C/R hand-held meters are designed


    Original
    pF-199 pF-50 esr meter Digital Frequency Meter with LCD Display lcr meter circuit LCR Components capacitors ESR Tester capacitor LCR meter digital capacitance meter Capacitor 0.25 uF LCR TL08C 830C PDF

    EMC PCB Layout

    Abstract: pcb thermal Design guide pcb trace signal path designer MIL-HDBK-241B
    Text: Guillaume Girard LCR Electronics Inc. 1 Solving Electromagnetic Coupling Problems by Spatial Component Placement. Guillaume Girard EMC Engineer LCR Electronics Inc. 9 Forest Avenue Norristown, PA, 19401 United States Telephone: 610 278-0840 Fax: (610) 278-0935


    Original
    0-7803-4703X. EMC PCB Layout pcb thermal Design guide pcb trace signal path designer MIL-HDBK-241B PDF

    LCR Components capacitors

    Abstract: EP0884-PNF LCR Components EP0880-PNF EP0881-PNF EP0882-PNF EP0885-PNF EP0886-PNF EP9001-PNF
    Text: LCR. NYLON LCR COMPONENTS MOUNTING CLIP. For TUBULAR CAPACITORS. revised 20/2/96 issue 4 ceST N », 09104 'SC series 'S C SERIES For surface or central mounting. Metal clips can cut through the insulating sleave and cause problems which cannot occur with an insulating NYLON clip.


    OCR Scan
    EP0881-PNF* EP9001-PNF* EP0882-PNF EP0880-PNF* EP0884-PNF* EP0885-PNF EP0886-PNF LCR Components capacitors EP0884-PNF LCR Components EP0880-PNF EP0881-PNF EP9001-PNF PDF

    inductor measurement on 4284A

    Abstract: 16065A 16048D 16451B 4285A-201 4284A1 5965-4792E 16047A 4285A-202 4284A-002
    Text: Agilent 4284A/4285A Precision LCR Meter Family 20 Hz to 1 MHz 75 kHz to 30 MHz Technical Overview A new standard for precise component, semiconductor and material measurements Agilent precision LCR meter family Utilize state-of-the art measurement technologies


    Original
    284A/4285A inductor measurement on 4284A 16065A 16048D 16451B 4285A-201 4284A1 5965-4792E 16047A 4285A-202 4284A-002 PDF

    universal MOTOR speed control using scr

    Abstract: abstract for universal MOTOR SPEED CONTROL USING IGBT universal MOTOR SPEED CONTROL USING IGBT speed control of 1 phase induction motor by using scr Triac trigger circuit Popular Electronics Magazine, October 1978 triac inductor noise suppression carbon monoxide detector induction motor speed control used triac based ac motor speed control circuit with triac
    Text: Integrating EMI Filters and Appliance Motor Controls Mr. Carl J. Dister LCR Electronics, Inc. 9 South Forest Avenue Norristown, PA 19401 U.S.A. Telephone: 1-800-527-4362 Fax: 610 278-0935 Email: [email protected] WEB Site: www.lcr-inc.com Carl J. Dister


    Original
    PDF

    CSM-10A

    Abstract: Multimeter calibration manual Multimeter service manual NI PXI-2527 PXI-4072 digital multimeter multimeter probes PXI-2527 PXI-2530 761000-01
    Text: 61⁄2-Digit Digital Multimeter, 1.8 MS/s Isolated Digitizer, and LCR Meter NI PXI-4072 • Multifunction device • 61⁄2-digit digital multimeter • 1.8 MS/s isolated digitizer • LCR meter inductance, capacitance, and resistance • 20 built-in measurements


    Original
    61/2-Digit PXI-4072 23-bit Vista/XP/2000 342574B-01* 342574B-01 2007-9223-101-D-A CSM-10A Multimeter calibration manual Multimeter service manual NI PXI-2527 PXI-4072 digital multimeter multimeter probes PXI-2527 PXI-2530 761000-01 PDF

    LCR1210

    Abstract: CR1210-2W LCR2010 LCR2512 CR0402-16W CR1206-4W cr2512-2w 0.022 j.100 resistor 270 ohm CR2010-2W
    Text: Chip Resistors – CR, LCR and ULCR Features • Flat Chip Resistors for surface mount applications • LCR and ULCR for current sensing applications Dimensions L C C C C T w 01005 0201 0402 0603 0805 1206 1210 2010 2512* L Length Inches (mm) 0.016 ± .0008


    Original
    0/-100ppm/v: 90ppm/V LCR1210 CR1210-2W LCR2010 LCR2512 CR0402-16W CR1206-4W cr2512-2w 0.022 j.100 resistor 270 ohm CR2010-2W PDF

    Untitled

    Abstract: No abstract text available
    Text: Chip Resistors – CR, LCR and ULCR Features • Flat Chip Resistors for surface mount applications • LCR and ULCR for current sensing applications Dimensions L C C C C T w 01005 0201 0402 0603 0805 1206 1210 2010 2512* L Length Inches (mm) 0.016 ± .0008


    Original
    079ee PDF

    resistor 2 MEG 0.5W

    Abstract: CR0402-16W
    Text: Chip Resistors – CR, LCR and ULCR Features • Flat Chip Resistors for surface mount applications • LCR and ULCR for current sensing applications Dimensions L C C C C T w 01005 0201 0402 0603 0805 1206 1210 2010 2512* L Length Inches (mm) 0.016 ± .0008


    Original
    PDF

    1-800-lcr-4emc

    Abstract: itt capacitor 092M switch 092M-02 lcr 085.00601.00 F9100 092M-03 LCR 092.02023.00 080M 094m
    Text: LCR. your global source for EMI filters, electronic controls and assemblies. ^ 'L C S t E L m c m o m c s , incC ENGINEERED PRODUCT SOLUTIONS IN A CUSTOMER FOCUSED CULTURE MISSION STATEMENT LCR is dedicated to providing economically viable control and EMC


    OCR Scan
    IS091 1-800-lcr-4emc itt capacitor 092M switch 092M-02 lcr 085.00601.00 F9100 092M-03 LCR 092.02023.00 080M 094m PDF

    ES51919/ES51920

    Abstract: Cyrustek
    Text: ES51919/ES51920 LCR meter chipset Features Application • 19,999/1,999 counts dual LCD display Handheld LCR bridge meter • Current consumption: Typ. 14 mA @ 100kHz QFP-100L package for ES51919 SSOP-48L package for ES51920 Description The chipset of ES51919/ES51920 is suitable


    Original
    ES51919/ES51920 100kHz QFP-100L ES51919 SSOP-48L ES51920 ES51919/ES51920 ES51920 Cyrustek PDF

    16047A

    Abstract: No abstract text available
    Text: ► ► ► Molded Unshielded RF Coils * The LCR Series has been designed to eliminate problems that arise when trying to correlate inductance values of coils manufactured to Q-meter specifications U.S. military which are measured on an HP impedance analyzer or LCR meters.


    OCR Scan
    HP-4275A HP-16047A H3-16061-70022 015pH 16047A PDF

    lcr meter circuit

    Abstract: LCR400 en61326 001H 1nF-100 high precision lcr meter
    Text: CYAN MAGENTA YELLOW BLACK CYAN MAGENTA YELLOW BLACK LCR400 low-cost precision LCR bridge Bridging the price-performance gap Lower cost through innovative design Anyone who has tried to purchase a high accuracy meter for LCR measurement at a reasonable cost will have discovered


    Original
    LCR400 RS-232 10kHz lcr meter circuit en61326 001H 1nF-100 high precision lcr meter PDF

    Untitled

    Abstract: No abstract text available
    Text: Chip Resistors – CR, LCR and ULCR Features • Flat Chip Resistors for surface mount applications • LCR and ULCR for current sensing applications Dimensions L C C C C T w 01005 0201 0402 0603 0805 1206 1210 2010 2512* L Length Inches (mm) 0.016 ± .0008


    Original
    PDF

    CR0402-16W

    Abstract: No abstract text available
    Text: Chip Resistors – CR, LCR and ULCR Features • Flat Chip Resistors for surface mount applications • LCR and ULCR for current sensing applications Dimensions L C C C C T w 01005 0201 0402 0603 0805 1206 1210 2010 2512* L Length Inches (mm) 0.016 ± .0008


    Original
    PDF

    lcr1210

    Abstract: 1206 chip resistor size in mm CR0402-16W
    Text: Chip Resistors – CR, LCR and ULCR Features • Flat Chip Resistors for surface mount applications • LCR and ULCR for current sensing applications Dimensions L C C C C T w 01005 0201 0402 0603 0805 1206 1210 2010 2512* L Length Inches (mm) 0.016 ± .0008


    Original
    079ee lcr1210 1206 chip resistor size in mm CR0402-16W PDF