AVA750
Abstract: No abstract text available
Text: e Phone: +49 7157/125-0 Fax: +49 7157/125-120 64,8 20,8 e www.telegaertner.com 5/8-24 UNEF ~97,5 hex 19 hex 60 D-71144 Steinenbronn Lerchenstrasse 35 Germany Mechanical characteristics K.Gärtner GmbH Alle Rechte vorbehalten / all rights reserved Telegärtner
|
Original
|
1818-B
D-71144
AVA7-50,
LCF158-50JA,
LDF7-50A,
J01020G0144
AVA750
|
PDF
|
Untitled
Abstract: No abstract text available
Text: 64,8 Phone: +49 7157/125-0 Mechanische Eigenschaften interface dimensions acc. to assembly code mating life coupling torque Steckgesicht nach Montageanleitung Steckzyklen Kupplungsdrehmoment Components centre contact outer contact other metal parts insulator
|
Original
|
M29x1
1818-B
LCF158-50JA,
LDF7-50A,
AVA7-50,
J01121H0139
|
PDF
|
LCF158-50A
Abstract: DOC-0000179128
Text: HUBER+SUHNER DATA SHEET Coaxial Cable Connector: 11_716-50-42-2/003_- Rev.: D Description Straight cable plug QUICK-FIT connector For outdoor applications Water protection according to IP 68 Technical Data Electrical Data Impedance Interface frequency max.
|
Original
|
DOU-00008431
DOU-00008433
DOC-0000179128
LDF7-50A,
LCF158-50A
DOC-0000184595
|
PDF
|
Untitled
Abstract: No abstract text available
Text: 64,8 Fax: +49 7157/125-120 Phone: +49 7157/125-0 Germany D-71144 Steinenbronn Lerchenstrasse 35 K.Gärtner GmbH Alle Rechte vorbehalten / all rights reserved Telegärtner b M29x1,5 www.telegaertner.com ~83 hook wrench DIN 1818-B 68-75 Hakenschlüssel hex 60
|
Original
|
M29x1
1818-B
LCF158-50JA,
LDF7-50A,
AVA7-50,
D-71144
2002/95/EC
J01121H0139
|
PDF
|
Untitled
Abstract: No abstract text available
Text: 64,8 Fax: +49 7157/125-120 Phone: +49 7157/125-0 Germany D-71144 Steinenbronn Lerchenstrasse 35 K.Gärtner GmbH Alle Rechte vorbehalten / all rights reserved Telegärtner f 5/8-24 UNEF www.telegaertner.com ~92 d hook wrench DIN 1818-B 52-55 Hakenschlüssel
|
Original
|
1818-B
LCF158-50JA,
LDF7-50A,
AVA7-50,
D-71144
J01021G0179
|
PDF
|
Untitled
Abstract: No abstract text available
Text: b Phone: +49 7157/125-0 Fax: +49 7157/125-120 64,8 www.telegaertner.com ~86 hex 32 Mechanical characteristics Germany D-71144 Steinenbronn Lerchenstrasse 35 K.Gärtner GmbH Alle Rechte vorbehalten / all rights reserved Telegärtner cable group / Kabelgruppe G26 1 5/8" :
|
Original
|
1818-B
LCF158-50JA,
LDF7-50A,
AVA7-50,
D-71144
2002/95/EC
J01120H0088
|
PDF
|
Untitled
Abstract: No abstract text available
Text: HELIAX Connector P R O D U C T S P E C I F I C A T I O N L7PNF-RPC N for LDF7-50A, Low Density Foam Dielectric Cable CHARACTERISTICS Components O-ring insulator O-ring (pin) O-ring (outer) O-ring (inner) Ball Bearings Rear Body Silicone Rubber Silicone Rubber
|
Original
|
LDF7-50A,
Temp-55
MIL-C-39012C-3
|
PDF
|
Untitled
Abstract: No abstract text available
Text: HELIAX Connector P R O D U C T S P E C I F I C A T I O N L7PDM-RPC 7/16 DIN for LDF7-50A, Low Density Foam Dielectric Cable CHARACTERISTICS Components Snap Ring Center Contact Phosphor Bronze Phosphor Bronze Silver Plate O-ring insulator O-ring (pin) Saw Guide
|
Original
|
LDF7-50A,
MIL-C-39012C-3
|
PDF
|
Untitled
Abstract: No abstract text available
Text: HELIAX Connector P R O D U C T S P E C I F I C A T I O N L7TDM-PS 7-16 DIN Male Positive Stop for 1-5/8" LDF7-50A HELIAX® CHARACTERISTICS Electrical Recommended maximum operating frequency, GHz 2.50 Cable Limited Peak power, max, kW 40.00 Connector Limited
|
Original
|
LDF7-50A
|
PDF
|
recommended torque
Abstract: No abstract text available
Text: TECHNICAL DATA SHEET 1/3 R185A.222.020 STRAIGHT JACK EZ FIT TYPE Series : ECO 7/16 1 5/8" CORRUGATED CABLE All dimensions are in mm. . pn . an COMPONENTS BODY CENTER CONTACT OUTER CONTACT INSULATOR GASKET OTHERS PARTS - MATERIALS PLATING µm BRASS BRONZE
|
Original
|
R185A
Voltage020
2500N
43/2Flats
57/2Flats
recommended torque
|
PDF
|
transistor 6823a
Abstract: AEROFLEX IFR 6844 CALIBRATION ifr 3205 cr 6848 6823a AEROFLEX IFR 6844 6845R SCALAR ANALYZERS 6820A cat 6822 m transistors 6822
Text: Contents RF & MICROWAVE SCALAR ANALYZERS 6820A SERIES and RF & MICROWAVE SYSTEM ANALYZERS 6840A SERIES Remote Operating Manual Document part no. 46892/921 REMOTE OPERATING MANUAL RF & MICROWAVE SCALAR ANALYZERS 6820A SERIES and RF & MICROWAVE SYSTEM ANALYZERS
|
Original
|
|
PDF
|
0926-A
Abstract: LDF7-50A
Text: TECHNICAL DATA SHEET 1/3 R185A.037.020 STRAIGHT PLUG EZ FIT TYPE Series : ECO 7/16 1 5/8" CORRUGATED CABLE All dimensions are in mm. . pn . an COMPONENTS BODY CENTER CONTACT OUTER CONTACT INSULATOR GASKET OTHERS PARTS - MATERIALS PLATING µm BRASS BRASS
|
Original
|
R185A
2500N
43/2Flats
57/2Flats
0926-A
LDF7-50A
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Phone: +49 7157/125-0 Fax: +49 7157/125-120 64,8 www.telegaertner.com ~87 hex 32 SW 32 Mechanical characteristics Germany D-71144 Steinenbronn Lerchenstrasse 35 cable group / Kabelgruppe G26 1 5/8" : RFA 1 5/8"-50, LCF158-50JA, LDF7-50A, AVA7-50, 5438A 1 5/8"-LD, HPL 50-1-5/8,
|
Original
|
1818-B
LCF158-50JA,
LDF7-50A,
AVA7-50,
D-71144
con95/EC
J01120H0088
|
PDF
|
Untitled
Abstract: No abstract text available
Text: www.teleqaertner.com 125-120 7157 Fax: +49 125-0 7157 Phone: +49 SW 32 SW 36 SW 60 Mechanical characteristics Mechanische Eigenschaften cables Kabel jT Hakenschlüssel G26: RFA 1 5/ 8”-5 0 , LCF158-50JA, LDF7-50A, ^ AVA7-50, 5438A 1 5/8”-LD, HPL 50-1-5/8,
|
OCR Scan
|
LCF158-50JA,
LDF7-50A,
AVA7-50,
J01120G
|
PDF
|
|
N male connector for LDF 2-50
Abstract: No abstract text available
Text: System Equipm ent D e s c rip tio n Tower See Pages 616-647 Guyed Self-Supporting Cellular Antenna Platform Tower Accessories 1 Wireless System P la n n in g The typical wireless system shown in the illustration may be used as a guide in planning your system.
|
OCR Scan
|
Plug/7-16
N male connector for LDF 2-50
|
PDF
|
WC109
Abstract: elliptical waveguide l46r WC166 wc 128 circular LDF7P-50A-1A 48940-C LDF4P-50A-1 L44R L5PNM
Text: Microwave and Wireless System Planning System Planning Worksheet. Ask for Andrew Bulletin 8740. System Using C ircular and E llip tica l Waveguide Towers Because we manufacture all the system components, Andrew has a unique understanding of how to design a tower to properly support transmission lines and hold
|
OCR Scan
|
H12PNF
H12PDM
2396A-2
2396A-4
2396A-5
19256B
4312A
WC109
elliptical waveguide
l46r
WC166
wc 128 circular
LDF7P-50A-1A
48940-C
LDF4P-50A-1
L44R
L5PNM
|
PDF
|
L4NM
Abstract: F4NMV2 f4nm L44PCW HJ9-50 L5NF 78AGM
Text: Connector Accessories A C on n e cto r P IN -P A K S . Replacement connector center pins individually packaged in sets quantities shown below . Each pin can be easily separated from the set. PIN-PAKS for 7/8" cable and smaller include five replacement pins: PIN-PAKS for 1-1/4“ and 1-5/8"
|
OCR Scan
|
LDF2-50
L44PCN
75ART,
75AGT
87SGT,
H12PNF,
78AGF,
78ARM,
78ARF,
78AGM,
L4NM
F4NMV2
f4nm
L44PCW
HJ9-50
L5NF
78AGM
|
PDF
|
Untitled
Abstract: No abstract text available
Text: www.teleqaertner.com 125-120 7157 Fax: +49 125-0 7157 Phone: +49 Mechanische Eigenschaften cables Kabel G26: RFA 1 5/ 8”-5 0 , LCF158-50JA, LDF7-50A, W AVA7-50, 5438A 1 5/8”-LD, HPL 50-1-5/8, HFC 42D, FlexLine 1 5/8” R interface dimensions acc. to mating life
|
OCR Scan
|
LCF158-50JA,
LDF7-50A,
AVA7-50,
J01121G0139
|
PDF
|
Untitled
Abstract: No abstract text available
Text: ASSEMBLY TOOLS Contents Page C rim p in g Tools fo r Flexible C ables . 4 0 3 Tool B o x e s . 4 0 5
|
OCR Scan
|
74Z-O
4-50B,
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Lerchenstrasse 35 Telefon 07157/125-0 Telefax 07157/125-120 Anschlußmaße nach IEC 1 6 9 -4 / mating face according to IEC 169-4 längs- und querdicht im gesteckten und nicht gesteckten Zustand min. 2.5 bar longitudinal and cross tightness (plugged and unplugged) min. 2.5 bar
|
OCR Scan
|
J01121A0106
CuZn39
CuZn39Pb3
LDF7-50A
7/16-Kabelbuchse
J01121A0106
|
PDF
|
J01121C
Abstract: J01121C0028 LDF7
Text: Steinenbronn Lerchenstrasse 35 Telefon 07157/125-0 Telefax 07157/125-120 Anschlußmaße nach IEC 1 6 9 -4 / mating face according to IEC 169-4 mit Aufkleber / with label J01121C0028] K.GäKner GmbH federnde Kontaktteile / spring contacts sonstige Metallteile / other metal parts
|
OCR Scan
|
J01121C0028]
CuZn39Pb3
Cu2Y-50
LDF7-50A
7/16-Kabelbuchse
7/16-Straiqht
J01121C
J01121C0028
LDF7
|
PDF
|
82496
Abstract: No abstract text available
Text: A rrestor Plus Lightning Surge P rotectors Ordering Information The Arrestor P lu st Lightning Surge Protector is a onepiece surge protector/HELlAX connector. It uniquely combines the reliability of quarter wave shorting stub technology with the proven performance of HELIAX
|
OCR Scan
|
|
PDF
|
FT5-50T
Abstract: FSJ175 LDF4-50-A EIA-222
Text: T i v Tin*«»* * '• Structural Considerations. Andrew hangers are designed for severe mechanical and environmental conditions. However, the mounting arrangement and structural integrity of the tower or structure, to which the hangers are attached, must be taken into account. A poorly
|
OCR Scan
|
RS-222
TIA-222-E)
throu5-50,
HJ5-50,
HJ5-75,
HT5-50
HJ7-50A.
EIA-222
FT5-50T
FSJ175
LDF4-50-A
|
PDF
|
HJ12-50
Abstract: lst series tower andrew L42P LDF12-50 LDF550A connector female F1PNR-H L4NM L44R Andrew 7/LDF1-50 HELIAX
Text: W ireless Base Station Applications HELIAX Coaxial Cable is the A nsw er f o r Your Wireless Base Station Applications C ellu lar D ispatch Paging 574 U ndrew : PCS SMR Trunking Andrew cables, connectors, and other accessories are designed to work together as an integrated system so
|
OCR Scan
|
|
PDF
|