Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MAGNETRON 60 KW Search Results

    MAGNETRON 60 KW Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    magnetron 60 kw

    Abstract: NLM915-60 NL-10258M magnetron* -coaxial National Electronics magnetron magnetron Water Cooled magnetron launcher NATIONAL ELECTRONICS nl-575a
    Text: NLM915-60 NATIONAL MAGNETRON 60 KW CW MAGNETR0N THE NLM915-60 IS A WATER COOLED, CERAMIC-METAL, CW MAGNETRON CAPABLE OF DELIVERING 60KW OF RF POWER INTO A MATCHED LOAD AT 915MHZ. IT IS INTENDED FOR USE IN INDUSTRIAL MICROWAVE PROCESSING AND DIELECTRIC HEATING


    Original
    NLM915-60 NLM915-60 915MHZ. NL-10258R MI10CFM 20CFM NL-10258L, NL-10258M, S/DATASHTS/IND/NLM915-60 magnetron 60 kw NL-10258M magnetron* -coaxial National Electronics magnetron magnetron Water Cooled magnetron launcher NATIONAL ELECTRONICS nl-575a PDF

    magnetron 60 kw

    Abstract: Magnetron 1.5 kW magnetron magnetron kw 9-GHz COOLED magnetron 1934 magnetron tunable frequency 60 kw
    Text: Q 0UR JDQHW V VMU 1934 Magnetron Description: 60 kW, Ku-band coaxial magnetron Features: • · · · · · · · · 150 Sohier Road Beverly, Massachusetts Beverly Microwave Division Frequency 14.7 – 14.9 GHz Peak Power Output 60 kW Duty Cycle .001 Anode Voltage 15 kV


    Original
    PDF

    magnetron 60 kw

    Abstract: magnetron magnetron* -coaxial magnetron kw pulse magnetrons magnetrons
    Text: Magnetrons SFD 325 Magnetron Description: 60 kW, Ku-band coaxial magnetron Features: • · · · · · · · · Frequency 16.0 – 17.0 GHz Peak Power Output 60 kW Duty Cycle .001 Anode Voltage 17 kV Anode Current 16 amps Pulse Width 2.5 microseconds Heater 12.6 volts @ 2.5 amps


    Original
    PDF

    magnetron

    Abstract: magnetron 60 kw magnetron kw ka band MAGNETRON COOLED magnetrons
    Text: Magnetrons SFD 332 Magnetron Description: 60 kW, Ka -band coaxial magnetron Features: • · · · · · · · · Frequency 32.9 – 33.5 GHz Peak Power Output 60 kW Duty Cycle .0004 Anode Voltage 18 kV Anode Current 16 amps Pulse Width 0.2 microseconds Heater 16 volts @ 5 amps


    Original
    PDF

    magnetron s-band kw

    Abstract: s-band coaxial magnetron magnetron magnetron S BAND 9-GHz magnetron kw s-band magnetrons S-Band magnetron 60 kw magnetron kw
    Text: Magnetrons VMS 1177 Magnetron Description: 800 kW, S-band coaxial magnetron Features: • · · · · · · · · Frequency 2.7 – 2.9 GHz Peak Power Output 800 kW Duty Cycle .001 Anode Voltage 33 kV Anode Current 60 amps Pulse Width 2.4 microseconds Heater 70 volts @ 3.2 amps


    Original
    PDF

    power supply for magnetron

    Abstract: magnetron magnetron 60 kw magnetrons magnetron power control kw POWER SUPPLY rf modulator datasheet magnetron kw power 220 power supply magnetron
    Text: Transmitters VPW 3487 Magnetron Modulator Features: • RF Output Power: 150 kW to 250 kW peak power, depending upon magnetron chosen. · Duty Cycle: .001 maximum · Pulsewidth: Four selectable pulsewidths from 0.25mSec to 2.0mSec · Input Power: 220 VAC, Single Phase, 50/60 Hz


    Original
    25mSec power supply for magnetron magnetron magnetron 60 kw magnetrons magnetron power control kw POWER SUPPLY rf modulator datasheet magnetron kw power 220 power supply magnetron PDF

    magnetron kw

    Abstract: magnetron magnetron* -coaxial
    Text: Q 0UR JDWQH V VMX 1942 Magnetron Description: 70 kW, X-band coaxial magnetron Features: • · · · · · · · · 150 Sohier Road Beverly, Massachusetts Beverly Microwave Division Frequency 9.355 – 9395 GHz Peak Power Output 60 kW Duty Cycle .001 Anode Voltage 16 kV


    Original
    PDF

    magnetron

    Abstract: C-band Magnetron VMC magnetrons C-Band magnetron magnetron 60 kw
    Text: Magnetrons VMC 1130 Magnetron Description: 800 kW, C-band coaxial magnetron Features: • · · · · · · · · Frequency 6.2 – 7.0GHz Peak Power Output 800 kW Duty Cycle .001 Anode Voltage 39 kV Anode Current 60 amps Pulse Width 1.3 microseconds Heater 5 volts @ 19 amps


    Original
    PDF

    Weather Radar

    Abstract: S-band magnetron 9 Ghz magnetron magnetron s-band kw magnetron VMS 1197B DOPPLER circuit magnetron doppler doppler radar magnetron kw s-band
    Text: Magnetrons VMS 1197B Magnetron Description: S-Band magnetron suitable for use in pulse doppler weather radars. Features: • · · · · · · · · · · Frequency 2.7 - 2.9 GHz Peak Power Output 750 kW min. Duty Cycle .0006 Anode Voltage 32 kV @ 60 amps Pulsewidth 4.0 mS


    Original
    1197B Weather Radar S-band magnetron 9 Ghz magnetron magnetron s-band kw magnetron VMS 1197B DOPPLER circuit magnetron doppler doppler radar magnetron kw s-band PDF

    magnetron 200

    Abstract: KT 0803 KT 0803 K TA 2092 N 10S6 2X10 sharp modulateur tube cathodique philips magnetron
    Text: PHILIPS [”55008 Packaged MAGNETRON for use as pulsed oscillator at a fixed frequency In the 8 .6 mm band between the 34512 and 35208 Kc/s limits. It Is capable of delivering a peak output power of more than 60 kW at a peak anode current of 17.5 A The magnetron is designed for very short pulse operation


    OCR Scan
    55GGS magnetron 200 KT 0803 KT 0803 K TA 2092 N 10S6 2X10 sharp modulateur tube cathodique philips magnetron PDF

    magnetron* -coaxial

    Abstract: L-4555 litton MAGNETRON ku L-4451 magnetron ka-band magnetron tunable frequency 60 kw ku band L-4419
    Text: COAXIAL PULSE 60 Kilowatts Minimum Peak Power Tunable Frequency 32,100 to 33,100 MHz The L-4555 is a rugged, compact, light-weight, tunable, Ka-band coaxial magnetron capable of delivering 60 KW peak output power across the frequency range of 32.1 to 33.1 GHz. Tuning is achieved with


    Original
    L-4555 L-4555 541/U L-4451 LITTON010 magnetron* -coaxial litton MAGNETRON ku L-4451 magnetron ka-band magnetron tunable frequency 60 kw ku band L-4419 PDF

    m1379

    Abstract: tuner ku band magnetron tunable frequency 60 kw ku band
    Text: I v i 1 T 3 O TUNABLE GENERAL M1379 DESCRIPTION is a m e c h a n i c a l l y frequency It X-BAND MAGNETRON range is p a c k a g e d GENERAL of an d tuned 9 0 60 x band to 9640 waveguide pulse magnetron, MHz output with type a peak an d designed output forced


    OCR Scan
    M1379 UG-40A/U tuner ku band magnetron tunable frequency 60 kw ku band PDF

    magnetron power control

    Abstract: WR112 ghz transmitter datasheet transmitter microwave transmitter VPX 3478 weight transmitter wr112 waveguide magnetrons microwave transmitter microwave waveguide
    Text: Transmitters VPX 3478 X-Band Transmitter Features: • Frequency: 8.5 - 9.6 GHz with VMX-1855 magnetron and VZW-9831 tuner. · Peak RF power output: 250 kW nominal · Duty cycle: .0011 · Pulsewidth: 1.25 mSec standard; others available · Input power: 380, 415, 440 VAC, 3-phase, 50/60 Hz, 2A


    Original
    VMX-1855 VZW-9831 115VAC, 400Hz WR112 cp250 magnetron power control ghz transmitter datasheet transmitter microwave transmitter VPX 3478 weight transmitter wr112 waveguide magnetrons microwave transmitter microwave waveguide PDF

    philips FP 9400

    Abstract: WR90 choke flange WR90 flange choke la 4445 ap magnetron 5kw LA 4445 magnetron 60 kw RG 52 M151 oscillateur
    Text: PHILIPS Packaged magnetron for use as pulsed oscillator, operating at a fixed frequency within the range 9345 to 9475 Mc/s and capable of delivering a peak output power of rain. 2.5 kW Magnetron avec aimant incorporé, pour utilisation comme oscillateur d'impulsions à une fréquence fixe dans la gamme


    OCR Scan
    10Mc/s- 15Mc/s/ philips FP 9400 WR90 choke flange WR90 flange choke la 4445 ap magnetron 5kw LA 4445 magnetron 60 kw RG 52 M151 oscillateur PDF

    national magnetron life

    Abstract: NLM915-50 power supply for magnetron electromagnet 15KV magnetron tube NL-10256M rs tube magnetron 200 kw magnetron power control
    Text: NLM915-50 A . NATIONAL MAGNETRON 2/5/91 page 1 of 7 50KW CW MAGNETRON The NLM915-50 is a water cooled, ceramic metal, CW magnetron delivering 50 KW of RF power into a matched load at 1, ntended for use in industrial microwave processing and dielectric heating appliances.


    OCR Scan
    NLM915-50 NLM915-50 915MHz. 1/4-28HF national magnetron life power supply for magnetron electromagnet 15KV magnetron tube NL-10256M rs tube magnetron 200 kw magnetron power control PDF

    5J26 magnetron

    Abstract: JB 2256 5J26 magnetron Philips schema 1220-1350 Magnetron pulse magnetrons 58725 magnetrons Philips 16NS
    Text: PHILIPS Î5J26 Forced-air cooled MAGNETRON for high power pulsed service, tunable over a frequency range from 1220-1350 Mc/s, capable of delivering a peak output power W0p > 500 kW. The mag­ netron requires an external magnet MAGNETRON refroidi par air forcé pour service d'impulsions de grande puissance.réglable dans la gamme


    OCR Scan
    PDF

    microwave oven magnetron

    Abstract: magnetron 5kw magnetron 1kw magnetron magnetrons Philips permanent magnet DC generator 6 kw power supply for magnetron magnetrons diagram induction heater magnetron 200
    Text: PHILIPS WATER COOLED MAGNETRON especially intended for use as a continuous wave power oscillator In industrial generators and in microwave ovens. It operates at a fixed frequency of 2450 ± 25 Mc/s and is capable of delivering an output power of 2 or 2.5 kw depending upon the voltage standing


    OCR Scan
    PDF

    YJ1600 magnetron data

    Abstract: YJ1600 power supply for magnetron YJ1600 YJ1600 magnetron magnetron national magnetron life 2.45 ghz magnetron 2.45 ghz magnetron electromagnet microwave oven magnetron magnetron oven
    Text: YJ1600 Magnetron A Ä V NATIONAL March 1991 P a g e l of 18 COHTINUOUS-WAVE 6 kW KAGVETROH Packaged, metal-ceramic, water cooled continuous-wave magnetron with integral RF cathode filter intended for use in industrial microwave heating applications. The tube features a quick-heating cathode, high


    OCR Scan
    YJ1600 YJ1600 YJ1600 magnetron data power supply for magnetron YJ1600 YJ1600 magnetron magnetron national magnetron life 2.45 ghz magnetron 2.45 ghz magnetron electromagnet microwave oven magnetron magnetron oven PDF

    power supply for magnetron

    Abstract: thermoswitch TL 0621 N magnetron* -coaxial tube cathodique philips antenne magnetron tube cathodique
    Text: PHILIPS 55125 WATER COOLED MAGNETRON especially Intended for use as continuous wave oscillator for microwave heating ap­ plications. It operates at a fixed frequency within the range of 2425-2475 Mc/s and is capable of delivering with unsmoothed D.C. supply an output power of 5 kW.


    OCR Scan
    PDF

    power supply for magnetron

    Abstract: welding machine wiring diagram microwave oven magnetron 2.45 ghz magnetron launcher wr340 magnetron 200 electrical welding transformer wiring diagram thyristor control arc welding machines circuit NL10230 welding machine transformer wiring diagram
    Text: SM 1050 SWITCHING POWER GENERATOR FOR 3 KW MAGNETRON SM 1050D: for main line 3 x 208V SM1050T: for main line 3 x 400V TECHNICAL NOTE SM 1050 Switch-mode power supplies for 3 kW magnetron Dichiarazione CE di Conformità CE Declaration of Conformity Nome del costruttore:


    Original
    1050D: SM1050T: SM1050 SM1050D SM1050T SMx45 SM1050 power supply for magnetron welding machine wiring diagram microwave oven magnetron 2.45 ghz magnetron launcher wr340 magnetron 200 electrical welding transformer wiring diagram thyristor control arc welding machines circuit NL10230 welding machine transformer wiring diagram PDF

    E3571

    Abstract: magnetron toshiba magnetron s band toshiba x-ray tube WR-90 power supply for magnetron toshiba magnetron magnetron* -coaxial sharp magnetron
    Text: Electron Tube, Device & Equipment TECHNICAL DATA MAGNETRON E 3 5 7 1 Toshiba magnetron E3571 is a fixed frequency pulsed type magnetron intended for use in radar systems of various kinds of ships, such as sail boats, and fishing boats. The peak output power is about 4 kW in


    OCR Scan
    E3571 WR-90 magnetron toshiba magnetron s band toshiba x-ray tube WR-90 power supply for magnetron toshiba magnetron magnetron* -coaxial sharp magnetron PDF

    mg5353

    Abstract: X-band marine radar x-band magnetron JST VHR-2N E2V Technologies Magnetron 1.5 kW power supply for magnetron e2v magnetron power supply for x-band magnetron E2V Technologies magnetron
    Text: MG5353 1.5 kW X-Band Magnetron DESCRIPTION The MG5353 is a fixed frequency pulse magnetron for use in marine radar systems. The peak power output is typically 1.5 kW at a frequency between 9380 and 9440 MHz. This tube is one of e2v technologies’ range of third generation


    Original
    MG5353 MG5353 MG5353, X-band marine radar x-band magnetron JST VHR-2N E2V Technologies Magnetron 1.5 kW power supply for magnetron e2v magnetron power supply for x-band magnetron E2V Technologies magnetron PDF

    TP116

    Abstract: WR975 waveguide AJ2194 circuit diagram of door interlock system magnetron 10 kw CPR975 BURLE-AJ2192 AJ2136V2 AJ2135 magnetron
    Text: Return To Product Page S94600E Magnetron Large Power Magnetron For Industrial Applications • • • • Ceramic-Metal Construction 50 kW CW at 915MHz All Magnetron Support Equipment Available Full Operating Guidance The BURLE S94600E is a fixed-tuned, magnetically


    Original
    S94600E 915MHz S94600E AJ2192 TP116 WR975 waveguide AJ2194 circuit diagram of door interlock system magnetron 10 kw CPR975 BURLE-AJ2192 AJ2136V2 AJ2135 magnetron PDF

    jrc magnetron

    Abstract: MSF1425A jrc radar magnetron magnetron X-band Magnetron 2 kW magnetron magnetron 5kw radar system msf*1425 magnetron 10 kw
    Text: MSF1425A X-Band Magnetron MSF1425A is designed for the magnetron of X-band radar system. The frequency range is fixed between 9.345GHz and 9.405GHz. The peak output power is 12.5kW. - MAXIMUM RATINGS -Min 3.0 0.05 - Max 7.0 50 0.001 1.0 90 Unit A kW us


    Original
    MSF1425A MSF1425A 345GHz 405GHz. jrc magnetron jrc radar magnetron magnetron X-band Magnetron 2 kW magnetron magnetron 5kw radar system msf*1425 magnetron 10 kw PDF