Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MAIN CIRCUIT BREAKER Search Results

    MAIN CIRCUIT BREAKER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TLP2701 Toshiba Electronic Devices & Storage Corporation Photocoupler (photo-IC output), 5000 Vrms, 4pin SO6L Visit Toshiba Electronic Devices & Storage Corporation
    74HC4053FT Toshiba Electronic Devices & Storage Corporation CMOS Logic IC, SPDT(1:2)/Analog Multiplexer, TSSOP16B, -40 to 125 degC Visit Toshiba Electronic Devices & Storage Corporation
    74HC4051FT Toshiba Electronic Devices & Storage Corporation CMOS Logic IC, SP8T(1:8)/Analog Multiplexer, TSSOP16B, -40 to 125 degC Visit Toshiba Electronic Devices & Storage Corporation
    TCKE800NA Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE800NL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, WSON10B Visit Toshiba Electronic Devices & Storage Corporation

    MAIN CIRCUIT BREAKER Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    T5N400

    Abstract: T4H250 PR222DS T4N250 PR221DS ABB TMAX T7 ABB Sace PR121 ABB T5N400 PR221DS sace tmax dip switch setting PR221DS-LS
    Text: Low voltage circuit breakers Working with trip characteristic curves Index 1. Introduction. 2 2. Main Definitions. 3


    Original
    PDF 1SXU210170B0201 LV170] T5N400 T4H250 PR222DS T4N250 PR221DS ABB TMAX T7 ABB Sace PR121 ABB T5N400 PR221DS sace tmax dip switch setting PR221DS-LS

    E173993

    Abstract: TG05-24 TG20-10 6607A TG20-24 TG10-28 TG05-10 TG05-36 en61558 TG05-28
    Text: TransGlobal TG Series International Transformer Printed Circuit Mount SPECIFICATIONS: ! WARNING INPUT: OUTPUT: INSULATION RATING: DIELECTRIC STRENGTH: AGENCY APPROVALS: ELECTROCUTION HAZARD Disconnect electric power to system at main fuse or circuit breaker box before


    Original
    PDF EN61558 EN60950 E173993 115/230V 50/60Hz P14A-XX-XX E173993 TG05-24 TG20-10 6607A TG20-24 TG10-28 TG05-10 TG05-36 en61558 TG05-28

    QOC24US

    Abstract: QOC30UF QOC24UF PK9GTA PK23GTA QOC30US PK12GTA QOC16US QO816L100F QOC16UF
    Text: QO Load Centers Indoor—Single Phase, Main Lug Class 736, 1130 www.SquareD.com FOR CURRENT INFORMATION Single Phase Three Wire—120/240 Vac—UL Listed Main Lugs Order QO, QOT, QO-EPD, QO-GFI and QO-PL Branch Circuit Breakers From Pages 1-2 and 1-3 LOAD CENTERS


    Original
    PDF Wire--120/240 Lugs--10 QO2L30Scd 1100CT9901. QOM50VH QOM60VH QOM70VH QOM80VH QOM90VH QOM100VH QOC24US QOC30UF QOC24UF PK9GTA PK23GTA QOC30US PK12GTA QOC16US QO816L100F QOC16UF

    NZMB1

    Abstract: NZMH2 NZMH2-A100 moeller 1250 NZMH HPL0211 NZMH2-M100 EN 60947 VDE 0660
    Text: N E W Moeller HPL0211-2003/2004 11/5 Moeller HPL0211-2003/2004 Overview Circuit-breakers, switch-disconnectors Overview Circuit-breakers, switch-disconnectors Circuit-breaker with main switch characteristics conform to IEC/EN 60204 and isolating characteristics conform to IEC/EN 60947, VDE 0660


    Original
    PDF HPL0211-2003/2004 NZMB1 NZMH2 NZMH2-A100 moeller 1250 NZMH HPL0211 NZMH2-M100 EN 60947 VDE 0660

    LB-1240

    Abstract: Stancor LB-6230
    Text: “Low Boy” Low Profile Split Bobbin-Printed Circuit Transformers SPECIFICATIONS: ! WARNING ELECTROCUTION HAZARD Disconnect electric power to system at main fuse or circuit breaker box before servicing. Failure to do so could result in death or serious injury.


    Original
    PDF 115/230VAC, 50/60Hz LB-1240 Stancor LB-6230

    SW-520

    Abstract: 12V .4A Transformer DSW-336 SW-420 transformer 32V CT 1,5A DSW-316 transformer 120V 12V 8A TRANSFORMER CT 1A 12v DSW-224 DSW-248
    Text: “Side Winder” SW / DSW Series Split Bobbin-Printed Circuit Transformers Single & Dual Primaries SPECIFICATIONS: ! WARNING INPUT: ELECTROCUTION HAZARD Disconnect electric power to system at main fuse or circuit breaker box before servicing. Failure to do so could result


    Original
    PDF 115VAC, 50/60Hz 115/230VAC, UL-506 to20V SW-520 12V .4A Transformer DSW-336 SW-420 transformer 32V CT 1,5A DSW-316 transformer 120V 12V 8A TRANSFORMER CT 1A 12v DSW-224 DSW-248

    Untitled

    Abstract: No abstract text available
    Text: “Side Winder” SW / DSW Series Split Bobbin-Printed Circuit Transformers Single & Dual Primaries SPECIFICATIONS: ! WARNING INPUT: ELECTROCUTION HAZARD Disconnect electric power to system at main fuse or circuit breaker box before servicing. Failure to do so could result


    Original
    PDF 115VAC, 50/60Hz 115/230VAC, UL-506 Certi120V

    earth leakage circuit

    Abstract: earth leakage diagram CURRENT TRANSFORMER Earth leakage SL7101
    Text: SL7101 EARTH LEAKAGE CURRENT DETECTOR Description The SL7101 is designed for use in earth leakage circuit interrupters for operation directly of the AC Line in breakers. It contains pre regulator, main regulator, after regulator, differential amplifier, level comparator, latch circuit. The input in


    Original
    PDF SL7101 SL7101 00V/200V 00V/200V 1-28V. earth leakage circuit earth leakage diagram CURRENT TRANSFORMER Earth leakage

    PR221DS

    Abstract: ABB T5N 630 PR221DS sace tmax dip switch setting PR221DS sace tmax T-max T3n 250 manual pr221ds ABB Sace Tmax PR221DS-LS IEC 60947-2 ABB SACE TMAX T2S 160 ABB ATS010 manual
    Text: Technical catalogue Tmax Low voltage moulded-case circuit-breakers up to 630 A Preliminary - 1SDC210004D0203 OVERVIEW MAIN CHARACTERISTICS THE RANGES ACCESSORIES CHARACTERISTIC CURVES AND TECHNICAL INFORMATION WIRING DIAGRAMS OVERALL DIMENSIONS ORDERING CODES


    Original
    PDF 1SDC210004D0203 PR021/K PR222DS/PD PR222MP PR212/CI PR222MP 1SDC210004D0203 PR221DS ABB T5N 630 PR221DS sace tmax dip switch setting PR221DS sace tmax T-max T3n 250 manual pr221ds ABB Sace Tmax PR221DS-LS IEC 60947-2 ABB SACE TMAX T2S 160 ABB ATS010 manual

    0313V

    Abstract: SMH4804 SMS44 25VREF
    Text: SUMMIT SMH4804 MICROELECTRONICS, Inc. User-Programmable Nonvolatile Distributed Power Hot Swap Controller with Forced Shutdown Preliminary FEATURES " Programmable Circuit Breaker Mode: Latched Volatile or Nonvolatile ! Soft Starts Main Power Supply on Card Insertion


    Original
    PDF SMH4804 0313V SMH4804 SMS44 25VREF

    wiring diagram ABB motor starter

    Abstract: IEC 60947-4-1 for ABB 1SAM350000R1011 IEC 60947-2 ABB MS132-12 1SAM350000R1014 MS132-32 IEC 60947-2 1SAM350000R1005 MS132-0
    Text: Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less against short-circuit, overload and phase failures.


    Original
    PDF MS132 D0201 wiring diagram ABB motor starter IEC 60947-4-1 for ABB 1SAM350000R1011 IEC 60947-2 ABB MS132-12 1SAM350000R1014 MS132-32 IEC 60947-2 1SAM350000R1005 MS132-0

    A 3120 V

    Abstract: X3120 din 3120
    Text: Undervoltage Release Module X3120-U.for circuit breaker 3120-F. Description Dimensions A module suitable for all double pole versions of type 3120 to trip the main switch/circuit breaker mechanism in the event of loss of voltage. When the voltage is restored the rocker switch must be reset to


    Original
    PDF X3120-U. 3120-F. A 3120 V X3120 din 3120

    SML-010

    Abstract: No abstract text available
    Text: DEMO MANUAL DC2060A LTC4229 Single Ideal Diode and Hot Swap Controller Description Demonstration circuit 2060A is a single-rail circuit with an ideal diode and Hot Swap functionality provided by the LTC 4229, ideal diode and Hot Swap controller. The main components of this circuit are two series connected


    Original
    PDF DC2060A LTC4229 DC2060A LTC4229 dc2060af SML-010

    earth leakage diagram

    Abstract: IL7101N EARTH LEAKAGE CURRENT DETECTOR
    Text: IL7101N TECHNICAL DATA IL7101N EARTH LEAKAGE CURRENT DETECTOR Description The IL7101N is designed for use in earth leakage circuit interrupters for operation directly oft the AC Line in breakers. It contains pre regulator, main regulator, after regulator,


    Original
    PDF IL7101N IL7101N 00V/200V 00V/200V 100mA earth leakage diagram EARTH LEAKAGE CURRENT DETECTOR

    TGC25-28

    Abstract: No abstract text available
    Text: TransGlobal TGC Series International Transformer Chassis Mount SPECIFICATIONS: ! WARNING ELECTROCUTION HAZARD Disconnect electric power to system at main fuse or circuit breaker box before servicing. Failure to do so could result in death or serious injury.


    Original
    PDF EN61558 EN60950 E173993 115/230V 50/60Hz PA41-XX-XX TGC25-28

    Untitled

    Abstract: No abstract text available
    Text: GL7101 GL7101 EARTH LEAKAGE CURRENT DETECTOR Top view Description The GL7101 is designed for use in earth leakage circuit interrupters for operation directly off the AC Line in breakers. It contains pre regulator, main regulator, after regulator, differential amplifier, level comparator,


    Original
    PDF GL7101 GL7101

    earth leakage diagram

    Abstract: ac voltage regulator using SCR circuit diagram varistor 100v KK7101 KK7101D KK7101N KK7101S GROUND FAULT INTERRUPTER EARTH LEAKAGE CURRENT Varistor
    Text: KK7101 GROUND FAULT INTERRUPTER EARTH LEAKAGE CURRENT DETECTOR KK7101 Description The KK7101N/D is designed for use in earth leakage circuit interrupters for operation directly off the AC Line in breakers. It contains pre regulator, main regulator, after regulator, differential


    Original
    PDF KK7101 KK7101N/D 00V/200V 00V/200V 012AA) earth leakage diagram ac voltage regulator using SCR circuit diagram varistor 100v KK7101 KK7101D KK7101N KK7101S GROUND FAULT INTERRUPTER EARTH LEAKAGE CURRENT Varistor

    GL7101

    Abstract: No abstract text available
    Text: GL7101 GL7101 EARTH LEAKAGE CURRENT DETECTOR Top view Description The GL7101 is designed for use in earth leakage circuit interrupters for operation directly off the AC Line in breakers. It contains pre regulator, main regulator, after regulator, differential amplifier, level comparator,


    Original
    PDF GL7101 GL7101

    ABB STOTZ - S 212

    Abstract: stotz s 212 mcb tripping curves ABB STOTZ-KONTAKT S 212 stotz 625 stotz r5402 ABB STOTZ-KONTAKT S 211 ABB Main Circuit breaker MCB ENERGY LET THROUGH
    Text: Selective main circuit breakers S 750 series Technical Data When connecting aluminium conductors ͧ 4 mm2 ensure that the contact surfaces of the conductors are cleaned, brushed and treated with grease. Re-tighten contact terminals after ca. 6 to 8 weeks.


    Original
    PDF D0202 12/09-3-ZVD) ABB STOTZ - S 212 stotz s 212 mcb tripping curves ABB STOTZ-KONTAKT S 212 stotz 625 stotz r5402 ABB STOTZ-KONTAKT S 211 ABB Main Circuit breaker MCB ENERGY LET THROUGH

    GROUND FAULT INTERRUPTER EARTH LEAKAGE CURRENT

    Abstract: earth leakage diagram IL7101 IL7101D IL7101N IL7101S
    Text: IL7101 GROUND FAULT INTERRUPTER EARTH LEAKAGE CURRENT DETECTOR IL7101 Description The IL7101N/D is designed for use in earth leakage circuit interrupters for operation directly off the AC Line in breakers. It contains pre regulator, main regulator, after regulator, differential


    Original
    PDF IL7101 IL7101N/D 00V/200V 00V/200V GROUND FAULT INTERRUPTER EARTH LEAKAGE CURRENT earth leakage diagram IL7101 IL7101D IL7101N IL7101S

    earth leakage circuit

    Abstract: earth leakage diagram ac voltage regulator using SCR circuit diagram KK54123 KK54123D KK54123N KK54123S
    Text: KK54123 GROUND FAULT INTERRUPTER EARTH LEAKAGE CURRENT DETECTOR KK54123 Description The KK54123N/D is designed for use in earth leakage circuit interrupters for operation directly off the AC Line in breakers. It contains pre regulator, main regulator, after regulator, differential


    Original
    PDF KK54123 KK54123N/D 00V/200V 00V/200V 012AA) earth leakage circuit earth leakage diagram ac voltage regulator using SCR circuit diagram KK54123 KK54123D KK54123N KK54123S

    GROUND FAULT INTERRUPTER EARTH LEAKAGE CURRENT

    Abstract: earth leakage diagram il54123 application diagram IL54123N IL54123 IL54123D IL54123S earth leakage circuit
    Text: IL54123 GROUND FAULT INTERRUPTER EARTH LEAKAGE CURRENT DETECTOR IL54123 Description The IL54123N/D is designed for use in earth leakage circuit interrupters for operation directly off the AC Line in breakers. It contains pre regulator, main regulator, after regulator, differential


    Original
    PDF IL54123 IL54123N/D 00V/200V 00V/200V GROUND FAULT INTERRUPTER EARTH LEAKAGE CURRENT earth leakage diagram il54123 application diagram IL54123N IL54123 IL54123D IL54123S earth leakage circuit

    Stancor p 8652

    Abstract: 8653 p Stancor Stancor power transformer P-8653 P-8656 37-6871A stancor transformer P-8380 P-8655
    Text: POWER TRANSFORMERS P-5016, P-8380, P-8652, P-8653, P-8655, P-8656 SPECIFICATIONS: ! WARNING ELECTROCUTION HAZARD Disconnect electric power to system at main fuse or circuit breaker box before servicing. Failure to do so could result in death or serious injury.


    Original
    PDF P-5016, P-8380, P-8652, P-8653, P-8655, P-8656 50/60Hz 37-6871B 7-6871A Stancor p 8652 8653 p Stancor Stancor power transformer P-8653 P-8656 37-6871A stancor transformer P-8380 P-8655

    GL7101

    Abstract: interrupter
    Text: GL7101 EARTH LEAKAGE CURRENT DETECTOR Pin Configuration Description The G L7101 is designed for use in earth leakage circuit interrupters for operation directly off the AC Line in breakers. It contains pre regulator, main regulator, after regulator, differential amplifier, level comparator, latch circuit. The in­


    OCR Scan
    PDF GL7101 GL7101 00V/200V interrupter