UE410-MM
Abstract: UE410-MU SICK 30 fgs UE410 IN40-D0101K sick 14 fgs 2P-250 UE410-2RO UE410-PRO3 SICK AG D-79183
Text: OPERATING INSTRUCTIONS UE410 Muting Modular Safety Controller GB Operating Instructions UE410 Muting This document is protected by the law of copyright, whereby all rights established therein remain with the company SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of
|
Original
|
UE410
UE410-MM
UE410-MU
SICK 30 fgs
IN40-D0101K
sick 14 fgs
2P-250
UE410-2RO
UE410-PRO3
SICK AG D-79183
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FEATURES Thermocouples Isolation Safety Barrier TC100PI-EX-SP 1 input & 1 output TC600PI-EX-SP (1 input & 2 output) —— TCx00PI-EX-SP Series ● Three-port isolation (input, output and power supply) ● High accuracy (0.1% F.S.) (Accuracy reduce with the smaller range)
|
Original
|
TC100PI-EX-SP
TC600PI-EX-SP
TCx00PI-EX-SP
35PPM/Â
RS485)
TCx00PI-EX
|
PDF
|
abzc
Abstract: line driver 7272
Text: Model HS52 Explosion Proof Hollow Shaft Incremental Encoder BEI Sensors The HS52 is the industry’s first UL and ATEX rated explosion proof hollow shaft encoder. Capable of operating directly in Division 1 or Zone 1 environments, the HS52 does not need an Intrinsic Safety barrier. This provides a simpler, more
|
Original
|
000-T16.
abzc
line driver 7272
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Installation Information LIPS X111 RUGGED STAND-ALONE LINEAR POSITION SENSOR INTRINSICALLY SAFE FOR HAZARDOUS GAS/VAPOUR ATMOSPHERES ATEX Qualified to Intrinsic Safety Standard Certificate number Sira 00ATEX2076X Barrier Supply Voltage: Barrier Output: Voltage BX002
|
Original
|
00ATEX2076X
BX002)
0-35V
BX003)
4-20mA
|
PDF
|
iec255 3a
Abstract: iec255 relay 14 pin INTRINSIC SAFE CIRCUIT namur standard 5 pin relay 6vdc 8 pin relay 30vdc DOWNLOAD DATA ABOUT RELAY SWITCH IEC255-4 protected safety barrier
Text: SW20XX-EX Isolating Switching Barrier FEATURES PRODUCT PROGRAM ● Fitted devices: 1. NAMUR Sensors; 2. Mechanical Joints. Part number ● Phase-angel and inverse control setting; ● Open circuit detection setting SW2001-EX ● Respective Isolation 2,500VDC between
|
Original
|
SW20XX-EX
SW2002-EX
SW2001-EX
500VDC
24VDC
220VAC
SW20XX-EX
iec255 3a
iec255 relay 14 pin
INTRINSIC SAFE CIRCUIT
namur standard
5 pin relay 6vdc
8 pin relay 30vdc
DOWNLOAD DATA ABOUT RELAY SWITCH
IEC255-4
protected safety barrier
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Switch Output isolation safety barrier —— TSFX02-EX Series FEATURES ●2-port electrical isolation between input and output ●Isolation voltage Intrinsically safe and no-intrinsically safe:2.5KVAC/60S ●High reliability(MTBF>500,000 hours) ●Protect: power reverse protect
|
Original
|
TSFX02-EX
5KVAC/60S)
TSF202-EX
2V/44mA,
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolating / Safety Switching Barrier Transistor Output ——TSX01-EX Series PART NUMBER SYSTEM FEATURES ●Fitted devices: 1. NAMUR Sensors; 2. Mechanical Joints. ● Phase-angel and inverse control setting; ● Open circuit detection setting ● Operation Temperature:-25°C to +71°C
|
Original
|
TSX01-EX
TS201-EX
TSX01-EX
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolated safety barrier TCx00PI-EX Series Thermocouple isolated safety barrier FEATURES z z z z z z z z z Input, output and power supply isolated from each other High accuracy 0.1% F.S. (The precision decreases with the reduction of the measuring range.
|
Original
|
TCx00PI-EX
2500VAC
50PPM/â
|
PDF
|
TSFx02W-EX
Abstract: Mornsun mornsun-power
Text: Isolated safety barrier TSFx02W-EX Series 12.5mm ultra-thin switch output isolated safety barrier FEATURES z Input, output are mutually isolated from each other z 12.5mm ultra-thin case z Isolation voltage Intrinsically safe and no-intrinsically safe:2KVAC/60S
|
Original
|
TSFx02W-EX
2KVAC/60S)
TSFx02W-EX
Mornsun
mornsun-power
|
PDF
|
thermal fuses color coding
Abstract: No abstract text available
Text: Special Application Fuses 242 Series Barrier Network Fuse Barrier Network Fuse 242 Series Description The 242 Series hazardous area barrier network fuse offers a range of fuses designed to enable greater safety operating electronic equipment within potentially explosive
|
Original
|
JDYX2-10480)
125OC.
125OC
MIL-STD-202F
050UAT1
thermal fuses color coding
|
PDF
|
"Isolation Amplifier" 4-20ma
Abstract: circuit diagram 0-10V industrial interface 4-20mA 0...5V INTRINSIC SAFE CIRCUIT "Isolation Amplifier" 0-10V 4.....20MA 24VDC power supply circuit diagram 0-10v to 4-20ma intrinsically safe dcs system
Text: ANALOG SIGNAL ISOLATING DETECTION BARRIER DESCRIPTION Analog signal isolating detection barrier, which can receive the current output from the hazardous PRODUCT PROGRAM Power Supply Part Number Nominal Range TII13-EX 24VDC TI513-EX TI613-EX Input Output Isolation
|
Original
|
TII13-EX
24VDC
TI513-EX
TI613-EX
18-32VDC
0-20mA)
4-20mA
"Isolation Amplifier" 4-20ma
circuit diagram 0-10V industrial interface
4-20mA 0...5V
INTRINSIC SAFE CIRCUIT
"Isolation Amplifier"
0-10V 4.....20MA
24VDC power supply circuit diagram
0-10v to 4-20ma
intrinsically safe
dcs system
|
PDF
|
Untitled
Abstract: No abstract text available
Text: DETECTION SAFETY BARRIER RS485 INPUT RS232 OUTPUT HALF-DUPLEX FEATURES l Three-port isolation (input, output and power supply) l High isolation voltage (2500VAC/60S) l High reliability (MTBF>500,000 hours) ——TD101-EX-485-xx Series GENERAL DESCRIPTION
|
Original
|
RS485
RS232
2500VAC/60S)
TD101-EX-485-xx
TD101-EX-485-xx
RS-485
RS-232
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Special Application Fuses 242 Series Barrier Network Fuse Barrier Network Fuse 242 Series Description The 242 Series hazardous area barrier network fuse offers a range of fuses designed to enable greater safety operating electronic equipment within potentially explosive
|
Original
|
JDYX2-10480)
125OC.
125OC
MIL-STD-202F
050UAT1
|
PDF
|
Untitled
Abstract: No abstract text available
Text: RS485 (Full-duplex)input isolation safety barrier TD102-EX-485 RS485 Full-duplex output TD103-EX-485(RS232 output) FEATURES l Three-port isolation (input, output and power supply) l High isolation voltage (2500VAC/60S) l High reliability (MTBF>500,000 hours)
|
Original
|
RS485
TD102-EX-485
RS485
TD103-EX-485
RS232
2500VAC/60S)
TD10x-EX-485
RS-485
RS-232
IEC/EN61326
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: DETECTION SAFETY BARRIER RS485 INPUT RS485 OUTPUT HALF-DUPLEX FEATURES l Three-port isolation (input, output and power supply) l High isolation voltage (2500VAC/60S) l High reliability (MTBF>500,000 hours) ——TD100-EX-485-xx Series GENERAL DESCRIPTION
|
Original
|
RS485
2500VAC/60S)
TD100-EX-485-xx
TD100-EX-485-xx
RS-485
|
PDF
|
Untitled
Abstract: No abstract text available
Text: 12.5mm ULTRA-THIN ANALOG SIGNAL OUTPUT ISOLATION SAFETY BARRIER —— TAF1xxW-EX-xx Series FEATURES ●3-port isolation input, output and power supply nonintrinsic safety:2.5KVAC/60S) ●High accuracy (0.1% F.S.) ●High linearity (0.1% F.S.) ●Low Output Ripple & Noise(≤60MVP-P )
|
Original
|
5KVAC/60S)
60MVP-P
50PPM/Â
EN61326
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolated safety barrier TD10x-EX-485-xx FULL-DUPLEX Series FEATURES RS485 INPUT RS485 OUTPUT (FULL-DUPLEX) l TD102-EX-485-xx(RS485 output) TD103-EX-485-xx(RS232 output) l l Input, output and power supply isolated from each other High isolation voltage (2500VAC/60S)
|
Original
|
TD10x-EX-485-xx
RS485
TD102-EX-485-xx
TD103-EX-485-xx
RS232
2500VAC/60S)
TD10x-EX-485-xx
RS-485
|
PDF
|
TSx01W-EX-xx
Abstract: Mornsun mornsun-power
Text: Isolated safety barrier TSx01W-EX-xx Series Ultra-thin detection type switch Isolated Barrier FEATURES z Suitable for connecting devices: 1. Namur sensor 2. The mechanical contacts z Shell design for 12.5mm ultra thin z Disconnection detection function setting
|
Original
|
TSx01W-EX-xx
5KVAC/60S)
Mornsun
mornsun-power
|
PDF
|
TSx00W-EX-xx
Abstract: Mornsun mornsun-power
Text: Isolated safety barrier TSx00W-EX-xx Series FEATURES Ultra-thin detection type switch Isolated Barrier z Suitable for connecting devices: 1. Namur sensor 2. The mechanical contacts z Shell design for 12.5mm ultra thin z Disconnection detection function setting
|
Original
|
TSx00W-EX-xx
5KVAC/60S)
Mornsun
mornsun-power
|
PDF
|
Untitled
Abstract: No abstract text available
Text: PROGRAMMABLE THERMOCOUPIES ISOLATION SAFETY BARRIER —— TCxxxPW-EX Series FEATURES ●Isolation input, output and power supply ●12.5mm slim case ● High accuracy (0.1% F.S.) ● High linearity (0.1% F.S.) ● Low temperature drift(50PPM/°C) ● Low-power dissipation
|
Original
|
50PPM/Â
|
PDF
|
mtl7760ac
Abstract: mtl 7796 MTL7756ac MTL7787P MTL7787 MTL 7756ac MTL7778ac MTL7706 MTL7798 MTL7761ac
Text: MTL7700 Series Shunt-diode safety barriers Instruction Manual INM7700 CONTENTS 1 2 3 4 OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
|
Original
|
MTL7700
INM7700
mtl7760ac
mtl 7796
MTL7756ac
MTL7787P
MTL7787
MTL 7756ac
MTL7778ac
MTL7706
MTL7798
MTL7761ac
|
PDF
|
SOD80 diode Marking Code AA
Abstract: general semiconductor DIODE SOD80
Text: BAS86 VISHAY Vishay Semiconductors Small Signal Schottky Barrier Diode Features • For general purpose applications • This diode features low turn-on voltage. The devices are protected by a PN junction guard ring against excessive voltage, such as electrostatic
|
Original
|
BAS86
DO-35
BAT86.
OD-80)
D-74025
11-Mar-04
SOD80 diode Marking Code AA
general semiconductor DIODE SOD80
|
PDF
|
Untitled
Abstract: No abstract text available
Text: BAS86 VISHAY Vishay Semiconductors Small Signal Schottky Barrier Diode Features • For general purpose applications • This diode features low turn-on voltage. The devices are protected by a PN junction guard ring against excessive voltage, such as electrostatic
|
Original
|
BAS86
DO-35
BAT86.
OD-80)
D-74025
03-Feb-04
|
PDF
|
TRxxxPW-EX
Abstract: Mornsun mornsun-power
Text: Isolated safety barrier TRxxxPW-EX series ultra-thin programmable thermal resistance isolated safety barrier FEATURES Input, output and power supply isolated from each other 12.5mm slim case High accuracy 0.1% F.S. High linearity (0.1% F.S.) low temperature drift (50PPM/℃)
|
Original
|
50PPM/â
TRxxxPW-EX
Mornsun
mornsun-power
|
PDF
|