Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    STEAM CONDENSER Search Results

    STEAM CONDENSER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    NFM15PC755R0G3D Murata Manufacturing Co Ltd Feed Through Capacitor, Visit Murata Manufacturing Co Ltd
    NFM15PC435R0G3D Murata Manufacturing Co Ltd Feed Through Capacitor, Visit Murata Manufacturing Co Ltd
    NFM15PC915R0G3D Murata Manufacturing Co Ltd Feed Through Capacitor, Visit Murata Manufacturing Co Ltd
    DE6B3KJ151KA4BE01J Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6B3KJ471KB4BE01J Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd

    STEAM CONDENSER Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    steam CONDENSER

    Abstract: condensers 10 mf CONDENSER steam turbine for the condenser air cooler ABB Group "steam condenser" ABB/steam CONDENSER
    Text: S T E A M C O N D E N S Development of large steam condensers with optimized cost/performance ratio E R S All the technical and commercial characteristics of a product are defined during its development. The way in which these characteristics pass from the development stage to the sales, tendering


    Original
    PDF

    steam turbine

    Abstract: steam CONDENSER small steam turbine 10 mw gas turbine 10 mw reheat steam turbine welding p91 steam turbine application turbine gas turbine generator gas pressure reducing station
    Text: S T E A M T U R B I N Advanced steam turbine technology for improved operating efficiency E S over two casings, ensuring optimum wall thickness and an optimum flange configuration on the outer casing. Both casings have a simple cylindrical basic shape. The horizontally split inner casing of


    Original
    68-GT-4, CH-5401 steam turbine steam CONDENSER small steam turbine 10 mw gas turbine 10 mw reheat steam turbine welding p91 steam turbine application turbine gas turbine generator gas pressure reducing station PDF

    ABB KENT-TAYLOR valve

    Abstract: steam CONDENSER ABB KENT-TAYLOR transmitter automatic plant watering circuit kent taylor IEC348 8036 ABB KENT-TAYLOR EIL8036 abb sensor 8036
    Text: Data Sheet Sodium Monitor SS/8036_5 Model 8036  Wide measuring range 0.01gkg–1 to 10mgkg–1 – covers all power station applications  Full sample temperature compensation – maximises measurement accuracy  'Pumpless' liquid handling section


    Original
    SS/8036 01gkg 10mgkg 160mm SS/8036 ABB KENT-TAYLOR valve steam CONDENSER ABB KENT-TAYLOR transmitter automatic plant watering circuit kent taylor IEC348 8036 ABB KENT-TAYLOR EIL8036 abb sensor 8036 PDF

    steam CONDENSER

    Abstract: pt1000 temperature sensor schematic water level sensor schematic diagram modicon PT1000 PT1000 application note SODIUM schematic inductive sensor flow automatic plant watering automatic plant watering circuit
    Text: Data Sheet SS/8037 Issue 6 Sodium Monitor 8037 „ Wide measuring range – covers all power plant applications „ Automatic sample temperature compensation – maximizes measurement accuracy „ 'Pumpless' liquid handling section – ensures low maintenance


    Original
    SS/8037 SS/8037 steam CONDENSER pt1000 temperature sensor schematic water level sensor schematic diagram modicon PT1000 PT1000 application note SODIUM schematic inductive sensor flow automatic plant watering automatic plant watering circuit PDF

    K3755

    Abstract: MA257E two cavity klystron klystron 5716B ELECTROMAGNET Photoresistor any type steam CONDENSER klystron tubes amphenol socket ma257e
    Text: K3755 EEV High Power Amplifier Klystron for UHF Television Service FEATURING * Frequency Range single tube. 470 to 860 MHz Bands IV and V in a * High Efficiency 50% typical sync. efficiency at 74 kW output in standard operational mode at the least efficient


    Original
    K3755 K3755, MA257E two cavity klystron klystron 5716B ELECTROMAGNET Photoresistor any type steam CONDENSER klystron tubes amphenol socket ma257e PDF

    Untitled

    Abstract: No abstract text available
    Text: 61.%$  •61.%$ •61.%$ IR T h e r m o m e t e r P R O 61.%$  61.%$ 61.%$ w w w .T IF.c o m Specification TIF7610 -76 to +932 ° F -60 to +500 ° C Measurement Range Infrared Overview: Thermocouple Measurement Range Infrared is the name given to a range of electromagnetic


    Original
    TIF7610 TIF7612 TIF-05-001 PDF

    English Electric Valve

    Abstract: English Electric Valve company ltd BW1121J2 B1153 Br1161 BW1121 BW1176J2 steam CONDENSER CP 1005 TRIODE ftl8
    Text: ENGLISH ELECTRIC VALVE CO LTD Product Data T riodes POWER T R IO D E S G E N E R A L SEC TIO N M E D IU M POWER T R IO D E S H IG H POWER T R IO D E S POWER T R IO D E ACCESSORIES = The Valve Data Book comprises ten bound volumes, made up as follows: • IGNITRONS


    OCR Scan
    BY4093 English Electric Valve English Electric Valve company ltd BW1121J2 B1153 Br1161 BW1121 BW1176J2 steam CONDENSER CP 1005 TRIODE ftl8 PDF

    Untitled

    Abstract: No abstract text available
    Text: METAL OXIDE VARISTORS TNRTM PRECAUTIONS AND GUIDELINES 1 The performance of varistors may deteriorate, the inside elements may be damaged, and they cause the varistors to smoke or catch fire, if the following precautions are not observed. 1 Do not use varistors in places whose temperature exceeds their rated operating temperature due to direct sunlight or


    Original
    E1006S PDF

    boiler

    Abstract: sk k 1191 BR-710 4cv50 varian
    Text: 4CV50,000J T E C HN I C A L DATA VAPOR COO LED POWER TETRODE The EIMAC 4CV50,000J is a ceramic/metal, vapor-cooled power tetrode intended for use at the 50 to 100 kilowatt output power level. This tube is characterized by low input and feedback capacitances and low internal


    OCR Scan
    4CV50 boiler sk k 1191 BR-710 4cv50 varian PDF

    BR-700

    Abstract: varian x-ray tube 4cv50 varian
    Text: TECHNICAL DATA VAPOR COOLED POWER TETRODE The EIMAC 4CV50,OOOE i s a ceramic,'metal, vapor-cooled power tetrode intended for use a t the 50 to 100 kilowatt output power level. This tube i s characterized by low input and feedback capacitances and low internal lead inductances. A rugged mesh thoriated tungsten filament provides adequate emission over the long operating life. It is recommended


    Original
    4CV50 BR-700 varian x-ray tube 4cv50 varian PDF

    Rectification Failure Relay

    Abstract: ac time overcurrent relay incomplete sequence relay ground detector relay 1500-TD210E-EN-E RE94 flame detector motor operated valve for gas relay 24 volt annunciator relay
    Text: IEEE Device Numbers and Functions PR ODUC TD ATA PRODUC ODUCT DA Bulletin 1500 Description The devices in switching equipment are referred to by numbers, with appropriate suffix letters when necessary, according to the functions they perform. These numbers are based on a system adopted by a standard for automatic swtichgear by IEEE, and


    Original
    1500-TD210E-EN-E 1500-TD210D-EN-E­ Rectification Failure Relay ac time overcurrent relay incomplete sequence relay ground detector relay 1500-TD210E-EN-E RE94 flame detector motor operated valve for gas relay 24 volt annunciator relay PDF

    4cx35000

    Abstract: RS1002A SRS4451 4CX5000 4CX1000A English Electric Valve 4cx1500 English Electric Valve company ltd QB4-1100 4CX10000
    Text: TETRODES GENERAL SECTION PENTODE r~ T ~ M EDIUM POWER T F T R n n F R = = HIGH POWER TETRODES POWER PENTODE , The Valve Data Book comprises ten bound volumes, made up as follows: • IG N ITR O N S R EC TIFIE R S IN D U S T R IA L T H Y R A TR O N S COLD CATHODE TUBES


    OCR Scan
    5CX1500A 4cx35000 RS1002A SRS4451 4CX5000 4CX1000A English Electric Valve 4cx1500 English Electric Valve company ltd QB4-1100 4CX10000 PDF

    Untitled

    Abstract: No abstract text available
    Text: Approval sheet Capacitor Arrays Series MULTILAYER CERAMIC CAPACITORS Automotive Capacitor Arrays Series MY Qualified to AEC-Q200 4 x 0402 NP0 & X7R Dielectrics *Contents in this sheet are subject to change without prior notice. Page 1 of 19 ASC_ Automotive Cap Array_(MY)_026B_AS


    Original
    AEC-Q200 PDF

    Rectification Failure Relay

    Abstract: automatic change over contactor circuit diagram Master sequence device static var compensator motor operated valve limit switch incomplete sequence relay Varistor z32 static var compensator medium voltage motor operated valve c37 ates
    Text: Relay symbols and device numbers; selection from IEC 617-, IEEE C37.2-1991 and IEEE C37.2-1979 Symbols and designations Symbols and designations, based on the IEC 617-series, IEC 617-7 1983 and others Block symbols and qualifying symbols 1. General block symbols


    Original
    617-series, 006-BEN Rectification Failure Relay automatic change over contactor circuit diagram Master sequence device static var compensator motor operated valve limit switch incomplete sequence relay Varistor z32 static var compensator medium voltage motor operated valve c37 ates PDF

    SK-2050

    Abstract: "Power Tubes" 4CW50 4-400 eimac
    Text: 4CW50,000J TEC H N IC A L DATA W A T E R COOLED P OWER TETRODE The EIMAC 4CW50,000J is a ceram ic/m etal, liquid-cooled power tetrode intended for use at the 50 to 100 kilowatt output power level. This tube is characterized by low input and feedback capacitances and low internal lead


    OCR Scan
    4CW50 Ave750 SK-2050 "Power Tubes" 4-400 eimac PDF

    schema power double 300

    Abstract: ABB RELAY RXM abb RMIO ABB RELAY - RXM rario ASEA RARIO rxido2 437A ABB tripping curves RXME ABB
    Text: A n a s ^a, Information RK 649-300 E i l » v sn o w m Edition £ s September 1974 F i l e RK 00-90 bo veri Section 6 A B B Relays Ne g a t i v e - s e q u e n c e PROTECTI OM T Y P E RARIO * Used to protect genera­ * Operates in two different tors , motors and synch­


    OCR Scan
    436-BB 436-B) 437-EB 437-B) 006-BB 006-EB schema power double 300 ABB RELAY RXM abb RMIO ABB RELAY - RXM rario ASEA RARIO rxido2 437A ABB tripping curves RXME ABB PDF

    epcos k276

    Abstract: steam CONDENSER M2020 NTC M1005 K276 EPCOS thermistor k276 absolute humidity sensor ntc m2020 NTC G540 evaporator
    Text: NTC Probes for HVAC and Home Appliances Product Profile 2002 http://www.epcos.com EPCOS AG 2 EPCOS AG Preview NTC probes are simply unbeatable as temperature sensors in HVAC heating, ventilation and air conditioning and domestic appliances. With their fast response and excellent measuring accuracy, these


    Original
    PDF

    Automotive Capacitors Series (MT)

    Abstract: No abstract text available
    Text: Approval sheet Automotive Capacitors MT _Qualified to AEC-Q200 MULTILAYER CERAMIC CAPACITORS Automotive Capacitors Series (MT) Qualified to AEC-Q200 0402 to 1210 Sizes (10V to 630V) NP0, X7R Dielectrics RoHS Compliance *Contents in this sheet are subject to change without prior notice.


    Original
    AEC-Q200 60sec Automotive Capacitors Series (MT) PDF

    st-100sx

    Abstract: Arakawa ST-100SX jis C5003 mosfet induction heater MIL-STD-750b 750H C5003 C5700 ST-100S YG6260
    Text: [ 4 ] Handling Guide for Semiconductor Devices [ 4 ] Handling Guide for Semiconductor Devices [ 4 ] Handling Guide for Semiconductor Devices 1. Using Toshiba Semiconductors Safely TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless,


    Original
    2SK1544 st-100sx Arakawa ST-100SX jis C5003 mosfet induction heater MIL-STD-750b 750H C5003 C5700 ST-100S YG6260 PDF

    ST-100SX

    Abstract: MIL-STD-750b 100SX C5700 jis C5003 750H C5003 ST-100S YG6260 mosfet induction heater
    Text: [ 4 ] Handling Guide for Semiconductor Devices [ 4 ] Handling Guide for Semiconductor Devices [ 4 ] Handling Guide for Semiconductor Devices 1. Using Toshiba Semiconductors Safely TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless,


    Original
    2SK1544 ST-100SX MIL-STD-750b 100SX C5700 jis C5003 750H C5003 ST-100S YG6260 mosfet induction heater PDF

    Sharp Semiconductor

    Abstract: No abstract text available
    Text: SHARP Quality Assurance System Sharp develops and produces a wide range of consumer and industrial-use semiconductor prod­ ucts. In recent years, the applications of ICs have ex­ panded significantly, into fields where extremely high levels of quality are critical.


    OCR Scan
    PDF

    ultrasonic plastic welder circuit

    Abstract: MP-F25
    Text: I MP-F FIBER SELFCONTAINED-DC TYPE Components fa advanced technology Aromat Plastic fiber type MP-F Photoelectric Sensors Coaxial fiber type Glass fiber type Metal tube type MP-F25 MP-F5 MP-FD1 MP-FH5-02 MP-FHD1-02 MP-FX1 MP-FSD1-7 Thru-beam (Thru-beam (Diffuse


    OCR Scan
    MP-F25 MP-FH5-02 MP-FHD1-02 ultrasonic plastic welder circuit PDF

    CA08104001E

    Abstract: westinghouse contactor westinghouse capacitor Westinghouse ampgard westinghouse switchgear westinghouse transformer 3750 KVA 9-0-9 step down transformer fusible 65k westinghouse transformer RBA-800
    Text: Fuses—Medium Voltage 9.0-1 September 2011 Fuses— Medium Voltage Sheet 09 001 Contents i Fuses—Medium Voltage General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.0-2 Current Limiting Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.0-4


    Original
    Section200E, 100SE, 125SE, 150SE, 175SE, 200SE CA08100005E CA08104001E CA08104001E westinghouse contactor westinghouse capacitor Westinghouse ampgard westinghouse switchgear westinghouse transformer 3750 KVA 9-0-9 step down transformer fusible 65k westinghouse transformer RBA-800 PDF

    ups transformer winding formula

    Abstract: SOLAR INVERTER 1000 watts circuit diagram ABB inverter motor fault code block diagram of hemodialysis machine Magnetic Field Sensor FLC 100 2.5 kva inverter diagrams
    Text: Power Distribution Systems 1.0-1 August 2013 Power Distribution Systems Sheet 01 001 Contents Power Distribution Systems System Design Basic Principles. . . . . . . . . . . 1.1-1 Modern Electric Power Technologies . . . . . . . . . . . 1.1-1 Goals of System Design . . . 1.1-2


    Original
    CA08104001E ups transformer winding formula SOLAR INVERTER 1000 watts circuit diagram ABB inverter motor fault code block diagram of hemodialysis machine Magnetic Field Sensor FLC 100 2.5 kva inverter diagrams PDF