Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TRANSFORMER FAULTS Search Results

    TRANSFORMER FAULTS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    WB1040-SML Coilcraft Inc Transformer Visit Coilcraft Inc
    AS8426-A Coilcraft Inc Telecom Transformer Visit Coilcraft Inc Buy
    B0727-B Coilcraft Inc Telecom Transformer Visit Coilcraft Inc Buy
    AS8954-A Coilcraft Inc Telecom Transformer Visit Coilcraft Inc
    CR7984-CLD Coilcraft Inc Datacom Transformer Visit Coilcraft Inc

    TRANSFORMER FAULTS Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: Data Sheet Burn Down Transformer ATG 6000 The powerful burn down transformer ATG 6000 is used to decrease the impedance of cable faults in medium and low voltage cable networks. The short circuit resistant 5.75 kVA transformer provides a maximum voltage of 15 kV and is enclosed in a fully encapsulated 19“ housing. The output voltage can


    Original
    6832-Sulz/Austria PDF

    electronic transformer

    Abstract: halogen transformer Transformer electronic transformer halogen SET105M electronic transformer halogen lamp electronic transformer installation transformer over heat protection transformer 240v halogen lamp electronic transformer
    Text: Instruction for the use of the electronic transformer for low voltage halogen lamps Model: SET105M Applications The transformer SET105M is dimmable electronic transformer both with leading edge and trailing edge dimmers for the use in halogen lamp systems (e.g. tube and rail systems,


    Original
    SET105M SET105M 30-240V~ 5-105W H03VVH2-F electronic transformer halogen transformer Transformer electronic transformer halogen electronic transformer halogen lamp electronic transformer installation transformer over heat protection transformer 240v halogen lamp electronic transformer PDF

    SET105R

    Abstract: Electronic transformer H03VVH2-F halogen transformer 35-105W electronic transformer halogen transformer over heat protection thermal fuse 230-240V specifications of power transformer
    Text: Instruction for the use of the electronic transformer for low voltage halogen lamps Model: SET105R Applications The transformer SET105R is exclusively designed for the use in halogen lamp systems e.g. tube and rail systems, halogen lamp sets, hanging lamps, ceiling lamps . The transformer


    Original
    SET105R SET105R 89/336/EEC 30-240V~ 5-105W H03VVH2-F Electronic transformer halogen transformer 35-105W electronic transformer halogen transformer over heat protection thermal fuse 230-240V specifications of power transformer PDF

    Halogen transformer

    Abstract: electronic transformer Transformer SET70M electronic transformer halogen trailing SCHEMATIC dimmer transformer 240v elco transformer H03VVH2-F halogen lamp electronic transformer
    Text: Instruction for the use of the electronic transformer for low voltage halogen lamps Model: SET70M Applications The transformer SET70M is dimmable electronic transformer both with leading edge and trailing edge dimmers for the use in halogen lamp systems (e.g. tube and rail systems,


    Original
    SET70M SET70M 30-240V~ 0-70W H03VVH2-F 50mm2 Halogen transformer electronic transformer Transformer electronic transformer halogen trailing SCHEMATIC dimmer transformer 240v elco transformer halogen lamp electronic transformer PDF

    60870-5-104

    Abstract: No abstract text available
    Text: Multilin T35 TRANSFORMER PROTECTION SYSTEM Cost-Effective Differential Protection for Transformers with up to 6 Sets of CTs KEY BENEFITS • Secure high-speed transformer differential protection with advanced features in a cost-effective package • Improved security for transformer energization and inrush


    Original
    ML2400-F-HI-HI-A2-A2-A6-F1 VP-1-61850 GEA-12671H 60870-5-104 PDF

    ethernet transformer

    Abstract: No abstract text available
    Text: HYDROCAL 1003 Transformer Online Monitoring System with Gas-in-Oil and Moisture in Oil Measurement Analysis of the gases dissolved in power transformer oil is recognized as the most useful tool for early detection and diagnosis of incipient faults in transformers.


    Original
    PDF

    11kV breaker control circuit diagram

    Abstract: power generation POWER COMMAND Hmi 211 100 kva transformer PROJECT REPORT ON 220 kv substation three winding power transformer ABB TMAX T7 HP 2231 opto coupler transformer calculation ret 521 EARTH fault RELAY AUTOMATIC ROOM LIGHT CONTROLLER ppt
    Text: Technical reference manual Transformer protection terminal RET 521*2.5 7HFKQLFDO UHIHUHQFH PDQXDO ProtectIT Transformer protection terminal RET 521*2.5 $ERXW WKLV PDQXDO DocID: 1MRK 504 036-UEN Issue date: December 2003 Revision: - Copyright 2003 ABB. All rights reserved.


    Original
    036-UEN SE-721 11kV breaker control circuit diagram power generation POWER COMMAND Hmi 211 100 kva transformer PROJECT REPORT ON 220 kv substation three winding power transformer ABB TMAX T7 HP 2231 opto coupler transformer calculation ret 521 EARTH fault RELAY AUTOMATIC ROOM LIGHT CONTROLLER ppt PDF

    GE Power Management multilin SR 745

    Abstract: GE multilin 750 GE Power Management multilin SR 750 relay GE 745 multilin multilin 745 C37-90 BS142 automatic 3 phase changer relay multilin
    Text: SR Transformer Management RelayTM 4 High-speed, multi-processor based relay for primary transformer protection and management. Features and Benefits Protection and Control • High-speed, multi-processor, three-phase ■ Two or three-winding ■ Adaptive relaying features


    Original
    808785E3 GE Power Management multilin SR 745 GE multilin 750 GE Power Management multilin SR 750 relay GE 745 multilin multilin 745 C37-90 BS142 automatic 3 phase changer relay multilin PDF

    Royer oscillator

    Abstract: laptop inverter ccfl MOSFET Royer oscillator sl-220J 4 CCFL Lamps Inverter buck royer inverter lcd cccv based battery charge controller toshiba ccfl inverter ccfl smb Royer oscillator circuit diagram
    Text: 19-1755; Rev 1; 3/01 Wide Brightness Range CCFL Backlight Controllers Features ♦ Fast Response to Input Change The MAX1739/MAX1839 monitor and limit the transformer center-tap voltage when required. This ensures minimal voltage stress on the transformer, which


    Original
    MAX1739/MAX1839 MAX1739/MAX1839 Royer oscillator laptop inverter ccfl MOSFET Royer oscillator sl-220J 4 CCFL Lamps Inverter buck royer inverter lcd cccv based battery charge controller toshiba ccfl inverter ccfl smb Royer oscillator circuit diagram PDF

    Royer oscillator

    Abstract: cccv royer inverter MOSFET Royer oscillator
    Text: 19-1755; Rev 1; 3/01 Wide Brightness Range CCFL Backlight Controllers Features ♦ Fast Response to Input Change The MAX1739/MAX1839 monitor and limit the transformer center-tap voltage when required. This ensures minimal voltage stress on the transformer, which


    Original
    MAX1739/MAX1839 MAX1739/ MAX1839 MAX1839 MAX1739/MAX1839 Royer oscillator cccv royer inverter MOSFET Royer oscillator PDF

    transformer calculation ret 521

    Abstract: automatic phase changer file 0-12 1a transformer step down transformer winding ratio automatic phase changer BO-02 tap transformer mva 3 phase automatic phase changer neutral and earth calculation 521 optocoupler
    Text: Transformer protection terminal RET 521*2.1 1MRK 504 012-BEN Page 1 Issued May 1999 Changed since March 1999 Data subject to change without notice SE960158 Features • Multiple function transformer protection terminal in a compact design - Overexcitation restraint with 5th harmonic


    Original
    012-BEN SE960158) 010-BEN 001-BEN 015-BEN 057-BEN S-721 transformer calculation ret 521 automatic phase changer file 0-12 1a transformer step down transformer winding ratio automatic phase changer BO-02 tap transformer mva 3 phase automatic phase changer neutral and earth calculation 521 optocoupler PDF

    D496

    Abstract: D505 VTM*48 VTM48EF020M080A00
    Text: VTM48EF020T080A00 VTM48ET020T080A00 VTM Transformer TM S C US C FEATURES • 48 Vdc to 2 Vdc 80 A transformer - Operating from standard 48 V or 24 V PRMTM regulators • High efficiency >92% reduces system power consumption • High density (272 A/in3)


    Original
    VTM48EF020T080A00 VTM48ET020T080A00 D496 D505 VTM*48 VTM48EF020M080A00 PDF

    VTM48ET030T070A00

    Abstract: VTM48EF030T070A00 D496 D505 ph-200 diode vtm48et
    Text: VTM48EF030T070A00 VTM48ET030T070A00 VTM Transformer TM S C US C FEATURES • 48 Vdc to 3 Vdc 70 A transformer - Operating from standard 48 V or 24 V PRMTM regulators • High efficiency >94% reduces system power consumption • High density (238 A/in3)


    Original
    VTM48EF030T070A00 VTM48ET030T070A00 VTM48ET030T070A00 VTM48EF030T070A00 D496 D505 ph-200 diode vtm48et PDF

    sac 187

    Abstract: D496 D505 VIV0102THJ
    Text: VTM48EH015T050A00 VTM48EH015M050A00 Formerly VIV0102THJ VTM Transformer TM S C FEATURES • 48 Vdc to 1.5 Vdc 50 A transformer - Operating from standard 48 V or 24 V PRMTM regulators • High efficiency (>89%) reduces system power consumption • High density (334 A/in3)


    Original
    VTM48EH015T050A00 VTM48EH015M050A00 VIV0102THJ) sac 187 D496 D505 VIV0102THJ PDF

    VTM48EF120T025A00

    Abstract: VTM48ET120T025A00 D496 sac 187 UV 471 D505 vtm48et
    Text: VTM48EF120T025A00 VTM48ET120T025A00 VTM Transformer TM S C US C FEATURES • 48 Vdc to 12 Vdc 25 A transformer - Operating from standard 48 V or 24 V PRMTM regulators • High efficiency >96% reduces system power consumption • High density (85 A/in3)


    Original
    VTM48EF120T025A00 VTM48ET120T025A00 VTM48EF120T025A00 VTM48ET120T025A00 D496 sac 187 UV 471 D505 vtm48et PDF

    500 MVA power transformers parameters

    Abstract: 1MRK000 multiple Transformer oil monitoring with automatic circuit breaking operation automatic 3 phase changer three-winding power transformer transformer calculation ret 521 automatic phase changer file RTXP 24 500 MVA power transformers automatic phase changer
    Text: JL » 1 1 n i p » Transformer protection terminal RET 521 1MRK 504 001-BEN Page 1 Issued June 1998 Changed since April 1998 Data subject to change without notice SE960158 Features Multiple function transformer protection ter­ minal in a compact design


    OCR Scan
    1MRK504 001-BEN SE960158) 010-BEN 015-BEN 1MRK511 057-BEN 500 MVA power transformers parameters 1MRK000 multiple Transformer oil monitoring with automatic circuit breaking operation automatic 3 phase changer three-winding power transformer transformer calculation ret 521 automatic phase changer file RTXP 24 500 MVA power transformers automatic phase changer PDF

    VIV0102THJ

    Abstract: 217F D496 D505 VIV0102MHJ
    Text: VIV0102THJ PRELIMINARY DATASHEET S C NRTL US VTM Transformer TM FEATURES • 38.4 Vdc – 1.2 Vdc 50 A Voltage Transformer - Operating from standard 48 V or 24 V PRMs • High efficiency >89% reduces system power consumption • High density (334 A/in3)


    Original
    VIV0102THJ VIV0102THJ 217F D496 D505 VIV0102MHJ PDF

    VTM48EF040T050A00

    Abstract: VTM48ET040T050A00 vtm48et D496 D505 VTM48EF040M050A00
    Text: VTM48EF040T050A00 VTM48ET040T050A00 VTM Transformer TM S C US C FEATURES • 48 Vdc to 4 Vdc 50 A transformer - Operating from standard 48 V or 24 V PRMTM regulators • High efficiency >94% reduces system power consumption • High density (170 A/in3)


    Original
    VTM48EF040T050A00 VTM48ET040T050A00 VTM48EF040T050A00 VTM48ET040T050A00 vtm48et D496 D505 VTM48EF040M050A00 PDF

    VTM48FH060T020A00

    Abstract: VTM48FH060M020A00 sac 187 D496 D505 VIV0105THJ
    Text: VTM48FH060T020A00 VTM48FH060M020A00 Formerly VIV0105THJ VTM Transformer TM S C FEATURES • 40 Vdc to 5 Vdc 20 A transformer - Operating from standard 48 V or 24 V PRMTM regulators • High efficiency (>94%) reduces system power consumption • High density (133 A/in3)


    Original
    VTM48FH060T020A00 VTM48FH060M020A00 VIV0105THJ) VTM48FH060T020A00 VTM48FH060M020A00 sac 187 D496 D505 VIV0105THJ PDF

    VTM48EH120T010A00

    Abstract: VTM48EH120M010A00 D496 sac 187 D505 VIV0101THJ NRTL VTM48EH120
    Text: VTM48EH120T010A00 VTM48EH120M010A00 Formerly VIV0101THJ VTM Transformer TM S C FEATURES • 48 Vdc to 12 Vdc 10 A transformer - Operating from standard 48 V or 24 V PRMTM regulators • High efficiency (>95%) reduces system power consumption • High density (901 W/in3)


    Original
    VTM48EH120T010A00 VTM48EH120M010A00 VIV0101THJ) VTM48EH120T010A00 VTM48EH120M010A00 D496 sac 187 D505 VIV0101THJ NRTL VTM48EH120 PDF

    22-A115-A

    Abstract: VTM48EH040T025A00 sac 187 D496 D505 VIV0104THJ VTM48EH040
    Text: VTM48EH040T025A00 VTM48EH040M025A00 Formerly VIV0104THJ VTM Transformer TM S C FEATURES • 40 Vdc to 3.3 Vdc 25 A transformer - Operating from standard 48 V or 24 V PRMTM regulators • High efficiency (>93%) reduces system power consumption • High density (167 A/in3)


    Original
    VTM48EH040T025A00 VTM48EH040M025A00 VIV0104THJ) 22-A115-A VTM48EH040T025A00 sac 187 D496 D505 VIV0104THJ VTM48EH040 PDF

    619-001E

    Abstract: wiring diagram for single phase starter Rxzk4 ABB LNG CT TEK 461 relay ZF 112 012 ralza 619-003E shunt reactor phase selector
    Text: Imo-No. INFORMATION RF 619-001 From/Date ASS Relays Reg. RFA, No\'ember 1988 Edition 4 E Page 743.5 1 Ultra High SpeedLine Protection type RALZA Unaffected by current transformer voltage transformer transients. saturation and capacitor Ultra high Spe-edof fault detection, typical 2-5 ms.


    Original
    11with 619-001E wiring diagram for single phase starter Rxzk4 ABB LNG CT TEK 461 relay ZF 112 012 ralza 619-003E shunt reactor phase selector PDF

    VIV0005TFJ

    Abstract: D496 D505
    Text: VIV0005TFJ US C S C VTM Transformer TM FEATURES • 40 Vdc to 1 Vdc 130 A transformer TM - Operating from standard 48 V or 24 V PRM regulators • 150 A rated with reduced case temperature at 30°C • High efficiency >91% reduces system power consumption


    Original
    VIV0005TFJ VTM48EF012T130A00 VIV0005TFJ D496 D505 PDF

    38CAVH1E

    Abstract: 38CAV 15.5CAVH1E 38CAVH auxiliary transformer 15.5CAV0.5E 12ABCN 38CAVH2E 24CAV2 38CAV4E
    Text: Voltage and Auxiliary Transformer Fuse Links British Standard VT Fuse Links. A range of voltage transformer primary Fuse Links to BS2692-1 and IEC60282-1. Wide range of ratings from 1 kV to 36 kV. 3.15 Amp industry standard current ratings. CAV range with ratings from 3.6kV to 38kV.


    Original
    BS2692-1 IEC60282-1. 7X101 4X102 2X102 8X101 5X100 8X100 4X101 38CAVH1E 38CAV 15.5CAVH1E 38CAVH auxiliary transformer 15.5CAV0.5E 12ABCN 38CAVH2E 24CAV2 38CAV4E PDF