Untitled
Abstract: No abstract text available
Text: FAN41501 Ground Fault Interrupter Self-Test Digital Controller Features Description • • Meets 2015 UL943 Self-Test GFCI Requirement Periodic EOL Testing without Compromising Normal GFCI Protection Built-in Noise Filters Reduce False EOL Signals
|
Original
|
PDF
|
FAN41501
UL943
90-Minute
com/dwg/MA/MA06A
dwg/PKG-MA06A
|
Untitled
Abstract: No abstract text available
Text: NCS37010 Self Test With Lockout Ground Fault Circuit Interrupter GFCI The NCS37010 is a fully UL943 compliant signal processor for GFCI applications with self test and lockout. The device integrates a flexible power supply (including both shunt and LDO regulators),
|
Original
|
PDF
|
NCS37010
NCS37010
UL943
NCS37010/D
|
Untitled
Abstract: No abstract text available
Text: NCS37010 Self Test With Lockout Ground Fault Circuit Interrupter GFCI The NCS37010 is a fully UL943 compliant signal processor for GFCI applications with self test and lockout. The device integrates a flexible power supply (including both shunt and LDO regulators),
|
Original
|
PDF
|
NCS37010
UL943
NCS37010/D
|
scr drive circuit diagram
Abstract: LM1851 LM1851AN RV4145M 5KQ30
Text: www.fairchildsemi.com LM1851 Ground Fault Interrupter Features • • • • No potentiometer required Direct interface to SCR Supply voltage derived from AC line—26V shunt Adjustable sensitivity • • • • Grounded neutral fault detection Meets UL943 standards
|
Original
|
PDF
|
LM1851
line--26V
UL943
LM1851
DS30001851
scr drive circuit diagram
LM1851AN
RV4145M
5KQ30
|
Untitled
Abstract: No abstract text available
Text: FAN41501 Ground Fault Interrupter Self-Test Digital Controller Features Description • • Meets 2015 UL943 Self-Test GFCI Requirement Periodic EOL Testing without Compromising Normal GFCI Protection Built-in Noise Filters Reduce False EOL Signals
|
Original
|
PDF
|
FAN41501
UL943
90-Minute
com/dwg/MA/MA06A
dwg/PKG-MA06A
|
schematic diagram DC circuit breaker
Abstract: ac voltage regulator using SCR circuit diagram scr drive circuit diagram schematic diagram ac voltage regulator 100-240 v schematic diagram Power supply 500w Ground fault Interrupter IC schematic diagram ac 220v voltage regulator schematic diagram for ac power line voltage conditioner LM1851 LM1851AN
Text: Electronics Semiconductor Division LM1851 Ground Fault Interrupter Features ¥ ¥ ¥ ¥ No potentiometer required Direct interface to SCR Supply voltage derived from AC lineÑ26V shunt Adjustable sensitivity ¥ ¥ ¥ ¥ Grounded neutral fault detection Meets UL943 standards
|
Original
|
PDF
|
LM1851
UL943
LM1851
DS3001851A
schematic diagram DC circuit breaker
ac voltage regulator using SCR circuit diagram
scr drive circuit diagram
schematic diagram ac voltage regulator 100-240 v
schematic diagram Power supply 500w
Ground fault Interrupter IC
schematic diagram ac 220v voltage regulator
schematic diagram for ac power line voltage conditioner
LM1851AN
|
SCHEMATIC circuit scr oscillator
Abstract: GFCI schematic
Text: NCS37000 Product Preview Ground Fault Circuit Interrupter GFCI Description The NCS37000 is a fully UL943 compliant signal processor for GFCI applications. The device integrates a flexible power supply (including both shunt and LDO regulators), differential fault, and
|
Original
|
PDF
|
NCS37000
UL943
QFN16
TSSOP-20
NCS37000/D
SCHEMATIC circuit scr oscillator
GFCI schematic
|
Untitled
Abstract: No abstract text available
Text: NCS37000 Product Preview Ground Fault Circuit Interrupter GFCI Description The NCS37000 is a fully UL943 compliant signal processor for GFCI applications. The device integrates a flexible power supply (including both shunt and LDO regulators), differential fault, and
|
Original
|
PDF
|
NCS37000
NCS37000
UL943
QFN16
NCS37000/D
|
Untitled
Abstract: No abstract text available
Text: NCS37010 Product Preview Self Test With Lockout Ground Fault Circuit Interrupter GFCI http://onsemi.com The NCS37010 is a fully UL943 compliant signal processor for GFCI applications with self test and lockout. The device integrates a flexible power supply (including both shunt and LDO regulators),
|
Original
|
PDF
|
NCS37010
NCS37010
UL943
NCS37010/D
|
SCR TRIGGER PULSE circuit
Abstract: Ground Fault IC pin diagram of SCR KA2807 off23
Text: www.fairchildsemi.com KA2807 Earth Leakage Detector Features Description • • • • • • KA2807 is a IC for ground fault circuit interrupters which are intended to provide electrical shock hazard protection from line-to-ground fault currents on grounded circuits of
|
Original
|
PDF
|
KA2807
KA2807
UL943
SCR TRIGGER PULSE circuit
Ground Fault IC
pin diagram of SCR
off23
|
E41978
Abstract: ul498 GFCI e419 GFPOEMM UL943 Ul-498
Text: Product Datasheet - GFPOEMM Product Datasheet GFPOEMM - Circuit Guard Manual Set Portable GFCI Line Cords 15 & 20A 120V 15' GFCI power supply cord with stripped leads, manual set. Product Specifications GFCI Product Type Line Cord Type Industrial Amperage
|
Original
|
PDF
|
UL498
UL943
E41978
UL94V-0
E41978
GFCI
e419
GFPOEMM
Ul-498
|
UJT 2N2646
Abstract: 2N2646 pin diagram UJT-2N2646 PIN DIAGRAM DETAILS UJT pin diagram 2N2646 pin diagram of UJT-2N2646 GE Transient Voltage Suppression Manual UJT THEORY AND CHARACTERISTICS 957B MDA2500 pn junction DIODE 1N4001
Text: TVS/Zener Theory and Design Considerations Handbook HBD854/D Rev. 0, Jun−2005 SCILLC, 2005 Previous Edition © 2001 as Excerpted from DL150/D “All Rights Reserved’’ http://onsemi.com 1 Technical Information, Application Notes and Articles Zener Diode Theory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
|
Original
|
PDF
|
HBD854/D
Jun-2005
DL150/D
NLAS3158/D
UJT 2N2646
2N2646 pin diagram
UJT-2N2646 PIN DIAGRAM DETAILS
UJT pin diagram 2N2646
pin diagram of UJT-2N2646
GE Transient Voltage Suppression Manual
UJT THEORY AND CHARACTERISTICS
957B
MDA2500
pn junction DIODE 1N4001
|
KA2807
Abstract: No abstract text available
Text: www.fairchildsemi.com K A2 8 0 7 Ea r t h Le a k a ge De t e c t or Features Description • • • • • The KA2807 is a IC for ground fault circuit interrupters which are intended to provide an electrical shock hazard protection from line to ground fault currents on grounded circuits of 120V supplies.
|
Original
|
PDF
|
KA2807
UL943
|
GFCI schematic
Abstract: No abstract text available
Text: NCS37012 Product Preview Self Test Ground Fault Circuit Interrupter GFCI Description • 6.0 – 12 Volt Operation (120 − 480 V AC mains with the appropriate • • • • • • • • • • • series impedance) −40 to 85°C Very Low Power Consumption: <15 mW @ 5 V
|
Original
|
PDF
|
NCS37012
UL943
NCS37012/D
GFCI schematic
|
|
GFCI schematic
Abstract: ON-MCR08 scr driver ic for rectifier 3 phase
Text: NCS37000 Ground Fault Circuit Interrupter GFCI Description Features • 6.0 – 12 Volt Operation (120 − 480 V AC mains with the appropriate • • • • • • • • • • series impedance) −40 to 85°C Very Low Power Consumption: <5 mW @ 5 V
|
Original
|
PDF
|
NCS37000
UL943
QFN16
TSSOP-20
NCS37000/D
GFCI schematic
ON-MCR08
scr driver ic for rectifier 3 phase
|
FM2807
Abstract: No abstract text available
Text: FM2807 Low Power Ground Fault Interrupter Specification Oct. 2007 FM2807 Low Power Ground Fault Interrupter Ver 1.0 Specification 1 INFORMATION IN THIS DOCUMENT IS INTENDED AS A REFERENCE TO ASSIST OUR CUSTOMERS IN THE SELECTION OF SHANGHAI FUDAN MICROELECTRONICS CO., LTD PRODUCT BEST SUITED TO THE CUSTOMER'S APPLICATION; THEY DO
|
Original
|
PDF
|
FM2807
|
Untitled
Abstract: No abstract text available
Text: 2 | PB-Series - Introduction PB-Series Ground Fault Circuit Protection The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments. The new PB-Series, AC Residual Current Circuit Breaker
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: FAN4147 Ground Fault Interrupter Features Description ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ The FAN4147 is a low-power Ground Fault Interrupter GFI controller for detecting hazardous current paths to ground and ground-to-neutral faults. The FAN4147 application circuit opens the load contacts before a
|
Original
|
PDF
|
FAN4147
FAN4147
|
ENR5201
Abstract: EDS-17 EDS271 EDS172 GFCI CPS152 CH-02 CROUSE-HINDS eds
Text: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-1010-3 Name: 2P-1010 2P 100: DATE: JAN 19 2006 Time: 6:08:35 PM Operator: RB GFS ground fault circuit interrupters are used: ɀ with portable electrical equipment such as tools, lighting systems, compressors and
|
Original
|
PDF
|
SYS19:
CRMAIN06-1010-3
2P-1010
CPS152
ENR5201
EDS-17
EDS271
EDS172
GFCI
CPS152
CH-02
CROUSE-HINDS eds
|
l943
Abstract: No abstract text available
Text: LINEAR INTEGRATED CIRCUIT KA2807 EARTH LEAKAGE DETECTOR T h e K A 2807 is d e s ig n e d fo r u se in e a rth c ir c u it in te r ru p te rs, fo r o p e ra tio n d ire c tly o ff th e A C lin e in te rru p te rs. F u ll a d va n ta g e o f th e U.S. UL943 tim in g s p e c ific a tio n
|
OCR Scan
|
PDF
|
KA2807
UL943
UL943
l943
|
scr 20f
Abstract: No abstract text available
Text: LINEAR INTEGRATED CIRCUIT KA2807 S DIP FEATURES • • • • • • • • • • Full Advantage Of The UL943 Built-In Voltage Regulator Sense Coll: 1000:1 GND/Neutral Coil: 200:1 Normal Fault Sensitivity Current Is 5mA Typical Trip Time In Normal Fault And Ground Neutral Fault
|
OCR Scan
|
PDF
|
KA2807
UL943
800Hz,
scr 20f
|
Untitled
Abstract: No abstract text available
Text: KA2807 LINEAR INTEGRATED CIRCUIT EARTH LEAKAGE DETECTOR KA2807 is a 1C for ground fault circuit interrupters which are intend ed to provide electrical shock hazard protection from line-to-ground fault currents on grounded circuits of 120V supplies. FEATURES
|
OCR Scan
|
PDF
|
KA2807
KA2807
UL943
800Hz,
|
Untitled
Abstract: No abstract text available
Text: PRECISION FAILSAFE TH ER M A L-FU SE RESISTORS CUSTOM DESIGN - V2 W to 60 W A TT msmt •v TF SERIES FEATURES The Ultimate Failsafe Design! ■ Instrinsically safe, completely flameproof. Component opens without hazard of overheating. ■ Meets UL, FCC, REA and EIA requirements
|
OCR Scan
|
PDF
|
100CVS
|
lm1851
Abstract: No abstract text available
Text: w w w .fa irc h ild s e m i.c o m S E M I C O N D U C T O R tm LM1851 Ground Fault I n t e r r u p t e r Features • • • • No potentiometer required Direct interface to SCR Supply voltage derived from AC line—26V shunt Adjustable sensitivity • •
|
OCR Scan
|
PDF
|
LM1851
UL943
LM1851
DS30001851
|