Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    VERIS HAWKEYE Search Results

    VERIS HAWKEYE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    10078239-10003LF Amphenol Communications Solutions DDR3 Memory Module Sockets, Storage and Server System, Very low profile (VLP) Through Hole, 240 Position Memory Socket. Visit Amphenol Communications Solutions
    10078239-10002LF Amphenol Communications Solutions DDR3 Memory Module Sockets, Storage and Server System, Very low profile (VLP) Through Hole, 240 Position Memory Socket. Visit Amphenol Communications Solutions
    10078239-11101LF Amphenol Communications Solutions DDR3 Memory Module Sockets, Storage and Server System, Very low profile (VLP) Through Hole, 240 Position Memory Socket. Visit Amphenol Communications Solutions
    10079192-11122LF Amphenol Communications Solutions DDR3 RDIMM, Storage and Server Connector, Very Low Profile, Vertical, Through Hole, 240 Position, 1.00mm (0.039in) Pitch Visit Amphenol Communications Solutions
    10078239-11123LF Amphenol Communications Solutions DDR3 UDIMM, Storage and Server Connector, Very Low Profile, Vertical, Through Hole, 240 Position, 1.00mm (0.039in) Pitch Visit Amphenol Communications Solutions

    VERIS HAWKEYE Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    H921

    Abstract: No abstract text available
    Text: VERIS INDUSTRIES INSTALLATION GUIDE CURRENT MONITORING H921 921 Split-Core Current Transducer 4-20mA Output Installer’s Specifications Sensor Power Insulation Class Frequency Temperature Range Humidity Range Amperage Range Output Hysteresis Off-State Leakage


    Original
    4-20mA 12-30VDC H921 PDF

    Veris hawkeye

    Abstract: H721HC din rail clip hawkeye 721HC Veris Industries H721LC 4-20ma DIGITAL CURRENT SOURCE DIN 921 limit switch bracket
    Text: CURRENT MONITORING 721LC/721HC/921 EASY 2-WIRE INSTALLATION! H721LC 48 Slide Switch Scaling Easy Setup WARRANTY H921 The Hawkeye 721LC, 721HC, & 921 provide accurate Loop powered analog current sensor simplifes installation load trending information with a proportional


    Original
    721LC/721HC/921 H721LC 721LC, 721HC, 4-20mA H721HC) 4-20mADC 600VAC 12-30VDC Veris hawkeye H721HC din rail clip hawkeye 721HC Veris Industries H721LC 4-20ma DIGITAL CURRENT SOURCE DIN 921 limit switch bracket PDF

    H908

    Abstract: No abstract text available
    Text: Installation Guide Current Monitoring TM TM H908 Split-Core Current Switch, Adjustable Trip Point Product Overview The H908 is a current-sensitive switching device that monitors current amperage in the conductor passing through it. A change in amperage in the monitored conductor that crosses the switch (setpoint) threshold plus the


    Original
    Z201494-0F H908 PDF

    H608

    Abstract: No abstract text available
    Text: Installation Guide Current Monitoring TM TM H608 Split-Core Current Switch, Adjustable Trip Point Product Overview The H608 is a current-sensitive switching device that monitors current amperage in the conductor passing through it. A change in amperage in the monitored conductor that crosses the switch (setpoint) threshold plus the


    Original
    Z201757-0H H608 PDF

    H909

    Abstract: H708 H709 hawkeye Veris hawkeye Hawkeye 708 H706 H906 Veris hawkeye 908 H908
    Text: CURRENT MONITORING 708/908 Series THE INDUSTRY STANDARD! 24 H708 Solid-core FI R -YE VE A H908 Split-core WARRANTY Solid- & Split-Core Adjustable Setpoint Digital Output Current Switches The Hawkeye 708/908 Series solid- and split-core Cost effective.reduced installation &


    Original
    600VAC 50/60Hz. 5-30VDC, 30VDC H708/908 H909 H708 H709 hawkeye Veris hawkeye Hawkeye 708 H706 H906 Veris hawkeye 908 H908 PDF

    Hawkeye 705

    Abstract: H904 hawkeye Veris hawkeye RMS-34 AH01 Veris Industries
    Text: CURRENT MONITORING 904 Solid- & Split-Core Adjustable Setpoint Digital Output VFD Current Switch The Hawkeye 904 microprocessor based current status switch provides a unique solution for monitoring status of motors controlled by variable frequency drives.


    Original
    600VAC Hawkeye 705 H904 hawkeye Veris hawkeye RMS-34 AH01 Veris Industries PDF

    H608

    Abstract: hawkeye Veris hawkeye 40HP hawkeye h608 hawkeye 608 AH01 H606 H609 AS15HP
    Text: CURRENT MONITORING 608 Series Mini Split-Core Adjustable Setpoint Digital Output Current Switches The Hawkeye 608 Series is a high per formance miniature split-core current status switch. Its low minimum setpoint 1.25A and small size make it ideal for monitoring status of small to medium


    Original
    600VAC 5-30VDC, 30VDC H608 hawkeye Veris hawkeye 40HP hawkeye h608 hawkeye 608 AH01 H606 H609 AS15HP PDF

    H931

    Abstract: hawkeye Veris hawkeye 3a30vdc DC Relay DIN 931 H721 100 vac to 4-20 ma 3A240VAC H921
    Text: H721/921/931 Loop Powered 4-20 mA Output Loop-powered analog current sensor with integral start/stop command relay • Reduces the number of installed components.saves time and space ■ Self-gripping split core for fast retrofit installation.no need to


    Original
    H721/921/931 H921/931 H931 hawkeye Veris hawkeye 3a30vdc DC Relay DIN 931 H721 100 vac to 4-20 ma 3A240VAC H921 PDF

    H932

    Abstract: hawkeye h922 3A30VDC H722 3A240VAC Veris hawkeye DC Relay din rail clip
    Text: H722/922/932 Self-powered 0 – 5 VDC Analog Current Sensors Self-powered analog current sensor with integral start/stop command relay H932 • Reduces the number of installed components.saves time and space ■ Self-gripping split core for fast retrofit installation.no need to


    Original
    H722/922/932 H922/932) H932 hawkeye h922 3A30VDC H722 3A240VAC Veris hawkeye DC Relay din rail clip PDF

    hawkeye

    Abstract: Veris hawkeye H221 H421 wiring diagram of universal motor medium voltage motor control center Veris hawkeye 800 H321 PS-24 ANALOG TO 4-20 MA
    Text: H221/321/421 High Amperage Split-cores Monitor larger motors and other loads from 100A to 2400A • Split-core design for easy installation ■ Eliminates need for external CTs on large conductors ■ Large openings for heavy conductors ■ Monitor critical motors compressor, fuel, etc.


    Original
    H221/321/421 H221/321/431 hawkeye Veris hawkeye H221 H421 wiring diagram of universal motor medium voltage motor control center Veris hawkeye 800 H321 PS-24 ANALOG TO 4-20 MA PDF