Abstract: delay Fuses Fuses class H LR29862
Text: KLPC Series POWR-PRO Class L Fuses 600 VAC • Time-Delay ■ 200 – 6000 Amperes SPECIFICATIONS Voltage Ratings: AC: 600 Volts DC: 480 Volts Interrupting Ratings: AC: 200,000 amperes rms symmetrical 300,000 amperes rms symmetrical Littelfuse self-certified .
|
Original
|
PDF
|
E81895)
E71611)
LR29862)
WF-1814
circuit-breakers
delay Fuses
Fuses class H
LR29862
|
Littelfuse FLNR 30
Abstract: FLSR_ID FLSR100ID LR600 LR250 LR29862 250 volt to 600 volt fuse
Text: FLNR_ID/FLSR_ID IndicatorTM Class RK5 Fuses 250/600 VAC • Dual-Element, Time Delay ■ 1/10 – 600 Amperes SPECIFICATIONS Voltage Ratings: AC: 250 Volts FLNR_ID ; 600 Volts (FLSR_ID) DC: 125 Volts (FLNR 1/10 – 30A); 125 Volts (FLNR_ID 35 – 600A); 300 Volts (FLSR_ID)
|
Original
|
PDF
|
E81895)
LR29862)
WF-1814
Littelfuse FLNR 30
FLSR_ID
FLSR100ID
LR600
LR250
LR29862
250 volt to 600 volt fuse
|
Untitled
Abstract: No abstract text available
Text: General Purpose Fuses FLNR_ID/FLSR_ID Indicator Class RK5 Fuses 250/600 VAC • Dual-Element, Time Delay • 1/10 – 600 Amperes Applications General Purpose Fuses Service entrance switches Switchboard main and feeder switches Motor control center mains and motor branch circuits
|
Original
|
PDF
|
|
E81895
Abstract: FLSR100ID LR250 LR29862 LR600 QPL - 8000 Series
Text: FLNR_ID/FLSR_ID IndicatorTM Class RK5 Fuses 250/600 VAC • Dual-Element, Time Delay ■ 1/10 – 600 Amperes SPECIFICATIONS Voltage ratings: AC: 250 Volts FLNR_ID ; 600 Volts (FLSR_ID) DC: 125 Volts (FLNR 1/10-30A); 125 Volts (FLNR_ID 35-600A); GENERAL 300 Volts (FLSR_ID)
|
Original
|
PDF
|
1/10-30A)
5-600A)
E81895)
LR29862)
E81895MPERES
E81895
FLSR100ID
LR250
LR29862
LR600
QPL - 8000 Series
|
Untitled
Abstract: No abstract text available
Text: POWR-GARD Fuse Datasheet ClassRK1–llNRK•llsRK•llsRK_IDseRIesFUses 250/600 VAC • Dual Element • Time-Delay • 1/10 -600 A QPL Ordering Information / 15/100 2/10 1/4 3/10 4/10 1/2 6/10 8/10 1 1 1/8 1 1/4 1 4/10 1 6/10
|
Original
|
PDF
|
|
Edison Fuse
Abstract: FUSEOLOGY NEC 2501 FLSR100ID LR250 LR29862 LR600 UL 248-15 3400A L300G30
Text: Next KLLU Class L Fuses 600 VAC • Time-Delay ■ 601 – 4000 Amperes SPECIFICATIONS Voltage Ratings: AC: 600 Volts DC: Contact factory Interrupting Ratings: 200,000 amperes rms symmetrical Ampere Range: 601 – 4000 amperes Approvals: Standard 248-10, Class L
|
Original
|
PDF
|
E81895)
LR29862)
Edison Fuse
FUSEOLOGY
NEC 2501
FLSR100ID
LR250
LR29862
LR600
UL 248-15
3400A
L300G30
|
mcl d01 94V0
Abstract: mcl d01 94vo lcd nec 2501 LD 229 TY 8016 thyristor LNNB001 mcl d01 display mcl d01 94VO 4300 MCL D01 94VO LCD DISPLAY FREE Bucket Elevator Design NH3 GL-GG
Text: POWR-GARD PRODUCTS CATALOG Littelfuse The World’s Leading Provider of Circuit Protection Solutions An Exceptional Portfolio Littelfuse is committed to providing every one of our customers with the right solutions to meet all of your circuit protection needs. Makes All the Difference
|
Original
|
PDF
|
PF101-11
mcl d01 94V0
mcl d01 94vo lcd
nec 2501 LD 229
TY 8016 thyristor
LNNB001
mcl d01 display
mcl d01 94VO 4300
MCL D01 94VO LCD DISPLAY
FREE Bucket Elevator Design
NH3 GL-GG
|
Littelfuse 16A 250v fuse
Abstract: FLSR100ID LR250 LR29862 LR600 Littelfuse FLNR 30 6002F FLSR_ID FLS-R-10
Text: General Purpose Fuses FLNR_ID/FLSR_ID Indicator Class RK5 Fuses 250/600 VAC • Dual-Element, Time Delay • 1/10 – 600 Amperes Applications General Purpose Fuses Service entrance switches Switchboard main and feeder switches Motor control center mains and motor branch circuits
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: POWR-GARD Fuse Datasheet Class RK1 – LLNRK • LLSRK • LLSRK_ID Series FUSES 250/600 VAC • Dual Element • Time-Delay • 1/10 -600 A QPL Ordering Information / 15/100 2/10 1/4 3/10 4/10 1/2 6/10 8/10 1 1 1/8 1 1/4 1 4/10 1 6/10 1 8/10 2 2 1/4 2 1/2
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: POWR-GARD Fuse Datasheet Class RK5 – FLNR_ID • FLSR_ID SERIES Indicator ® FUSES QPL 250/600 VAC • Dual Element • Time Delay • 1/10 -600 A Ordering Information / 1/8* 15/100 2/10 1/4 3/10† 4/10 1/2 1 10 / 8/10 1 1 1/8 1 1/4 1 4/10 1 1/2 1 6/10
|
Original
|
PDF
|
|
klystron lamps
Abstract: MIL-R-19523 MIL-R-5757 Mil-T-23648 MIL-S-8834 mil-s-8805 1000w inverter design and calculation MIL-R-39007 MIL-L-6363 MIL-STD-756
Text: MIL-HDBK-217F BEF?1991 SUPERSEDING MIL-HDBK-217E, 2 J8nwry 1990 MILITARY NotIce 1 HANDBOOK . RELIABILITY PREDICTION OF ELECTRONIC EQUIPMENT AMSC N/A DISTRIBUTION STATEMENT A: Approved for public release; distribution unlimited. MIL-HDBK-217F DEPARTMENT OF DEFENSE
|
Original
|
PDF
|
MIL-HDBK-217F
MIL-HDBK-217E,
t331ALTY
klystron lamps
MIL-R-19523
MIL-R-5757
Mil-T-23648
MIL-S-8834
mil-s-8805
1000w inverter design and calculation
MIL-R-39007
MIL-L-6363
MIL-STD-756
|
Littelfuse FLNR 30
Abstract: FLSR015ID LR29862 LFR60
Text: POWR-GARD Fuse Datasheet UL Class RK5 FLNR_ID/FLSR_ID SERIES Indicator ® FUSES QPL 250/600 VAC • Dual Element • Time Delay • 1/10 -600 Amperes Specifications Voltage Ratings: AC: 250 V FLNR_ID ; 600 V (FLSR_ID) DC: 125 V (FLNR 1 /10 – 30 A); 125 V (FLNR_ID 35 – 600 A);
|
Original
|
PDF
|
E81895)
LR29862)
WF-1814
-F-1814)
fuses15
Littelfuse FLNR 30
FLSR015ID
LR29862
LFR60
|
Untitled
Abstract: No abstract text available
Text: POWR-GARD Fuse Datasheet UL Class G SLC CLASS G FUSES 480/600 VAC • Time-Delay • 1/2 -60 Amperes QPL Specifications Voltage Ratings: Interrupting Ratings: Ampere Range: Approvals: 600 VAC 1 /2 – 20 A 480 VAC (25 – 60 A) 170 VDC (1 /2 – 60 A) (Littelfuse self-certified)
|
Original
|
PDF
|
E81895)
LR29862)
WF-1814
QPL-W-F-1814)
SLC010
|
Untitled
Abstract: No abstract text available
Text: POWR-GARD Fuse Datasheet CLASS J – JLS SERIES FUSES 600 VAC • Fast-Acting • 1-600 A QPL Ordering Information AMPERE RATINGS 1 3 6 10 15 20 25 30 35 40 TYPE NON-INDICATING 45 50 60 70 80 90 100 110 125 150 SERIES AMPERAGE JLS 110 175 200 225 250 300
|
Original
|
PDF
|
JLS110
0JLS110
LFJ60
|
|
Federal fuse switch
Abstract: LR29862
Text: POWR-PRO Fuses KLPC Series POWR-PRO® Class L Fuses 600 VAC • Time-Delay • 200 – 6000 Amperes POWR-PRO® Fuses current and are also as current-limiting as the fastest Class L fuse on the market. On average, the peak let-through currents of KLPC series fuses
|
Original
|
PDF
|
|
LR29862
Abstract: No abstract text available
Text: General Purpose Fuses JLS Class J Fuses 600 VAC • Fast Acting • 1 – 600 Amperes Space Saving • JLS fuse characteristics are similar to KLNR/KLSR fast acting Class RK1 fuses, but dimensionally are much smaller. Safety General Purpose Fuses
|
Original
|
PDF
|
|
E81895
Abstract: QPL-W-F-1814
Text: POWR-GARD Fuse Datasheet CLass J – JLS series FUSES QPL 600 VAC • Fast-Acting • 1-600 A Ordering Information ampere ratings 1 3 6 10 15 20 25 30 35 40 type non-indicating 45 50 60 70 80 90 100 110 125 150 series amperage JLS 110 175 200 225 250 300
|
Original
|
PDF
|
JLS110
0JLS110
LFJ60
E81895
QPL-W-F-1814
|
LR29862
Abstract: No abstract text available
Text: KLPC Series POWR-PRO Class L Fuses 600 VAC • Time-Delay ■ 200 – 6000 Amperes POWR-PRO FUSES SPECIFICATIONS Voltage ratings: AC: 600 Volts DC: 480 Volts Interrupting ratings: AC: 200,000 amperes rms symmetrical 300,000 amperes rms symmetrical Littelfuse self-certified .
|
Original
|
PDF
|
E81895)
E71611)
LR29862)
-F-1814
LR29862
|
MIL-PRF-15160
Abstract: KLK 15 Fuses 4AG fuse 87108 FUSEOLOGY
Text: Introduction to Circuit Protection Fuseology Fuse Facts The application guidelines and product data in this guide are intended to provide technical information that will help with application design. Since these are only a few of the contributing parameters, application testing is strongly recommended and should be used to verify performance in the
|
Original
|
PDF
|
EIA-296:
MIL-PRF-15160
KLK 15 Fuses
4AG fuse
87108
FUSEOLOGY
|
FLSR
Abstract: 250 volt to 600 volt fuse FLSR_ID Federal fuse switch LR29862 LR250 LR600 FLNR Littelfuse FLNR 30
Text: FLNR/FLSR Class RK5 Fuses 250/600 VAC • Dual-Element, Time-Delay ■ 1/10 – 600 Amperes SPECIFICATIONS Voltage Ratings: AC: 250 Volts FLNR ; 600 Volts (FLSR) DC: 125 Volts (FLNR) 300 Volts (FLSR) Interrupting Ratings: AC: 200,000 amperes rms symmetrical
|
Original
|
PDF
|
E81895)
LR29862)
WF-1814
FLSR
250 volt to 600 volt fuse
FLSR_ID
Federal fuse switch
LR29862
LR250
LR600
FLNR
Littelfuse FLNR 30
|
Untitled
Abstract: No abstract text available
Text: POWR-GARD Fuse Datasheet CLass J – JLS series FUSES 600 VAC • Fast-Acting • 1-600 A QPL Ordering Information ampere ratings 1 3 6 10 15 20 25 30 35 40 type non-indicating 45 50 60 70 80 90 100 110 125 150 series amperage JLS 110 175 200 225 250 300
|
Original
|
PDF
|
JLS110
0JLS110
LFJ60
|
Untitled
Abstract: No abstract text available
Text: FLNR/FLSR Class RK5 Fuses 250/600 VAC • Dual-Element, Time-Delay ■ 1/10 – 600 Amperes SPECIFICATIONS Voltage ratings: AC: 250 Volts FLNR ; 600 Volts (FLSR) DC: 125 Volts (FLNR) 300 Volts (FLSR) Interrupting ratings: AC: 200,000 amperes rms symmetrical
|
Original
|
PDF
|
E81895)
LR29862)
WF1814
|
LR29862
Abstract: FUSES 20 A RK1 fuses
Text: JLS CLASS J FUSES 600 VAC • Fast-Acting ■ 1 – 600 Amperes SPECIFICATIONS Voltage ratings: 600 Volts AC Interrupting ratings: 200,000 amperes rms symmetrical Ampere range: 1— 600 amperes Approvals: UL Listed Class J fuses per UL 248 formerly UL 198C
|
Original
|
PDF
|
E81895)
LR29862)
WF1814
LJ600
LR29862
FUSES 20 A
RK1 fuses
|
MIL-PRF-15160
Abstract: IEC 60127-1
Text: Littelfuse is a t yo u r service to help solve yo u r electrical protection problems. When contacting Littelfuse sales engineers, please have all the requirements o f yo u r applications available. Requests for quotes o r assistance in designing o r selecting special types o f circuit protection components
|
OCR Scan
|
PDF
|
EIA-296:
MIL-PRF-15160
IEC 60127-1
|