Untitled
Abstract: No abstract text available
Text: Technical guide OPERATING PARAMETERS OF ALARM RELAYS The well speed rotation information is treated by our RA alarm box see pages 164-166 . Frequency/voltage converter Speed sensor Data The reference cable-up (under speed rotation) starts the alarm. REF processing
|
Original
|
|
PDF
|
convergie
Abstract: bornier FUSIBLE DE 4A MS480
Text: Alimentations d'équipement Série CESAR Puissance 240 à 960 W Catégorie Industrielle Sortie monosource Marquage CE CARACTERISTIQUES GENERALES PROTECTIONS . Les alimentations sont conçues pour se raccorder à un réseau . Par fusible ou disjoncteur triphasé, neutre non-utilisé .
|
Original
|
10mm2)
EN61000-3-2
4V/40A
260x130x90
320x170x115
convergie
bornier
FUSIBLE DE 4A
MS480
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Technical guide III - FANS MOTOR TYPES Squirrel cage rotor with aluminium grade 5 conductor bar for 50/60 Hz versions and copper conductor bar for 400 Hz versions. These types of motors can be used in single phase by adding a split capacitor. Single phase motor
|
Original
|
UL94V0
|
PDF
|
125XR2181000
Abstract: convergie 125XR 125XR2182000
Text: AC Axial Fans 120 x 120 x 38 mm Approvals See selection guide pages 15 to 26 GAMT 1 listed Available with: Electrical protection: impedance protected Housing material: zamak Impeller material: plastic UL 94 VO Weight: 0,725 kg - flying leads - speed sensor
|
Original
|
125XL
125LG
125XR
125XR2181000
convergie
125XR
125XR2182000
|
PDF
|
selection
Abstract: No abstract text available
Text: Technical guide I - SELECTING A FAN Forced convection cooling is an effective solution to dissipate heat in electronic equipment. This technical guide will help you to determine the performance of the required fan for your application. BASIC REQUIREMENTS VOLTAGE: The first step is to determine the
|
Original
|
|
PDF
|
technologies
Abstract: No abstract text available
Text: Technical guide V - TECHNOLOGIES BEARING SYSTEMS tropical environment. In particular, protection against humidity complies with norm NFC20703 test 3B 21 days # MIL STD 202* methode 103B. CODE 14 - The reference is followed by 3 digits. They are allocated to each individual case.
|
Original
|
NFC20703
280DH2LP13000
280DH2LP14000
technologies
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Technical guide IX - LIFE EXPECTANCY The mechanical and electrical design, the choice of materials, and the high level of inspection give our fans excellent reliability. Special attention is given to bearings, both in design and production, i.e.: choice of bearings and lubricants, accurate machining, strict alignment, very careful balancing and
|
Original
|
|
PDF
|
convergie
Abstract: RTH1/10 0452H 7156 16 SAMPLE C PROJECTS in 6713 0304H avocet Linker
Text: HIĆTECH C XA Product Brief HIĆTECH C Complier for the Philips XA microcontroller - technical specifications HI-TECH Software’s range of ANSI C embedded development systems now includes a product targeted specifically at Philips Semiconductors’ XA (eXtended
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Technical guide V - TECHNOLOGIES BEARING SYSTEMS The fan rotors are equipped with two sleeve bearings or 2 sealed ball bearings lubricated for life, according to the required life expectancy, noise level and environmental conditions. They can also be equipped with mixed bearings.
|
Original
|
|