Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    E2V TECHNOLOGIES Search Results

    E2V TECHNOLOGIES Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CS-SATDRIVEX2-001 Amphenol Cables on Demand Amphenol CS-SATDRIVEX2-001 Serial ATA Extension Cable - SATA II Drive Extension Cable with Power (6.0 Gbps) 1m Datasheet
    CS-SATDRIVEX2-002 Amphenol Cables on Demand Amphenol CS-SATDRIVEX2-002 Serial ATA Extension Cable - SATA II Drive Extension Cable with Power (6.0 Gbps) 2m Datasheet
    CS-SATDRIVEX2-000.5 Amphenol Cables on Demand Amphenol CS-SATDRIVEX2-000.5 Serial ATA Extension Cable - SATA II Drive Extension Cable with Power (6.0 Gbps) 0.5m Datasheet
    CS-SASDDP8282-000.5 Amphenol Cables on Demand Amphenol CS-SASDDP8282-000.5 29 position SAS to SATA Drive Connector Dual Data Lanes Cable 0.5m Datasheet
    CS-SASDDP8282-001 Amphenol Cables on Demand Amphenol CS-SASDDP8282-001 29 position SAS to SATA Drive Connector Dual Data Lanes Cable 1m Datasheet

    E2V TECHNOLOGIES Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    CX1191

    Abstract: MA92 FX2519A MA94 CX1140 CX1835 FX-2519 5949A CX1191A FX2525
    Text: E2V Technologies Accessories for Hydrogen Thyratrons The following top cap connectors, sockets, cooling modules and resistor box are available for use with E2V Technologies hydrogen thyratrons. Type Outline Description MA91 Page 2 A five-contact B5F socket with flexible leads and terminal tags, and mounted on an


    Original
    CX1140 MA153 CX1191 MA92 FX2519A MA94 CX1835 FX-2519 5949A CX1191A FX2525 PDF

    CX2801

    Abstract: CX1574C CX1535 CX1585A CX1140 CX1157 CX1836A cx2804 e2v spark gaps Thyratron dc to ac inverter
    Text: E2V Technologies Hydrogen Thyratrons Preamble Table of Contents 1 INTRODUCTION . . . . . . . . . . . . . 2 DESCRIPTION . . . . . . . . . . . . . . 2 2 PRINCIPLES OF OPERATION . . . . . THE SWITCHING CYCLE . . . . . . . i. Voltage Hold-off . . . . . . . . ii. Commutation . . . . . . . . .


    Original
    180A-5 CX2801 CX1574C CX1535 CX1585A CX1140 CX1157 CX1836A cx2804 e2v spark gaps Thyratron dc to ac inverter PDF

    how to build vhf tv transmitter

    Abstract: two cavity klystron Colour television picture tube connection details klystron exciter for tv transmitter TPD170 water heater powered anode relative magnet permeability tungsten TUNABLE FILTER uhf vacuum tube amplifier
    Text: E2V Technologies The Mode of Operation of the EEV IOT Inductive Output Tube and its Use in UHF Television Transmitters CONTENTS 1 What is an IOT?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Where is the EEV IOT used? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2


    Original
    TPD170, how to build vhf tv transmitter two cavity klystron Colour television picture tube connection details klystron exciter for tv transmitter TPD170 water heater powered anode relative magnet permeability tungsten TUNABLE FILTER uhf vacuum tube amplifier PDF

    CX1151L

    Abstract: thyratron thyratron tube operation R2G1 MA360A
    Text: E2V Technologies CX1151L Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled, fast recovery tetrode thyratron, specifically designed for operation under medical linac conditions, but also


    Original
    CX1151L CX1151L, CX1151L thyratron thyratron tube operation R2G1 MA360A PDF

    FX1585

    Abstract: tag 8812 MA360A thyratron tube operation Thyratron E2V Technologies thyratron tube thyratrons TRANSFORMER 7700
    Text: E2V Technologies FX1585 Hydrogen-Filled Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled, flange mounted triode thyratron designed for high voltage modulator applications. It has a rugged internally


    Original
    FX1585 FX1585, FX1585 tag 8812 MA360A thyratron tube operation Thyratron E2V Technologies thyratron tube thyratrons TRANSFORMER 7700 PDF

    CX1154L

    Abstract: CX1154L thyratron CX1154 ka klystron pulse thyratrons Thyratron thyratron tube operation A1A-CX1154L klystron tubes schematic diagram heater
    Text: E2V Technologies CX1154L Deuterium Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron with ceramic/metal envelope, featuring fast recovery time, low jitter, firing time


    Original
    CX1154L CX1154 CX1154L, CX1154L CX1154L thyratron ka klystron pulse thyratrons Thyratron thyratron tube operation A1A-CX1154L klystron tubes schematic diagram heater PDF

    CX1154

    Abstract: thyratron tube operation thyratron tube thyratron
    Text: E2V Technologies CX1154B Double-Ended Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, double ended high voltage thyratron with ceramic/metal envelope, featuring low jitter, firing time and


    Original
    CX1154B CX1154B, CX1154 thyratron tube operation thyratron tube thyratron PDF

    CX1151

    Abstract: E2V Technologies tag 725 thyratrons thyratron
    Text: E2V Technologies CX1151 Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition


    Original
    CX1151 CX1151, CX1151 E2V Technologies tag 725 thyratrons thyratron PDF

    CX1135

    Abstract: thyratron tube operation thyratron tube thyratron
    Text: E2V Technologies CX1135 Hydrogen-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron with ceramic/metal envelope, featuring low jitter, firing time and drift. Suitable for switching


    Original
    CX1135 volt187 CX1135, CX1135 thyratron tube operation thyratron tube thyratron PDF

    CX1154C

    Abstract: CX1154 thyratron tube thyratron
    Text: E2V Technologies CX1154C Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled pentode thyratron with ceramic envelope, featuring high peak current, high rate of rise of current and


    Original
    CX1154C 1/16-inch CX1154C, CX1154C CX1154 thyratron tube thyratron PDF

    E2V Technologies

    Abstract: CX1171B cx117 thyratron tube operation thyratron tube thyratron A1A-CX1171BC CX1171BC
    Text: E2V Technologies CX1171BC Three-Gap, Double-Ended Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, three-gap, double-ended high voltage thyratron with ceramic/metal envelope, featuring low jitter,


    Original
    CX1171BC CX1171BC, E2V Technologies CX1171B cx117 thyratron tube operation thyratron tube thyratron A1A-CX1171BC CX1171BC PDF

    8503AF

    Abstract: CV6022 MA359 thyratron tube operation Thyratron A1A-8503AF thyratron tube E2V Technologies BS448 thyratrons
    Text: E2V Technologies 8503AF Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Flange mounted hydrogen-filled triode thyratron, positive grid, for pulse operation. A hydrogen reservoir is incorporated. The


    Original
    8503AF CV6022 8503AF, 8503AF MA359 thyratron tube operation Thyratron A1A-8503AF thyratron tube E2V Technologies BS448 thyratrons PDF

    thyratron tube operation 6587

    Abstract: thyratron tube operation thyratron tube 6587 thyratron tube thyratron thyratrons CV6022
    Text: E2V Technologies 6587 Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. PULSE MODULATOR SERVICE MAXIMUM AND MINIMUM RATINGS ABRIDGED DATA Absolute values Hydrogen-filled triode thyratron, positive grid, for pulse


    Original
    CV6022 MIL-E-1/1046. A4-18) thyratron tube operation 6587 thyratron tube operation thyratron tube 6587 thyratron tube thyratron thyratrons PDF

    CX1164

    Abstract: E2V Technologies thyratron A1A-CX1164 105 Thyratron
    Text: E2V Technologies CX1164 Hydrogen-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron with ceramic envelope, featuring low jitter and low anode delay time drift. Suitable for


    Original
    CX1164 CX1164 CX1164, E2V Technologies thyratron A1A-CX1164 105 Thyratron PDF

    4C35A

    Abstract: 4C35 Thyratron thyratrons FX2505 BS448 equivalent thyratron tube operation thyratron tube
    Text: E2V Technologies FX2505 Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled triode thyratron, positive grid, for pulse operation. A hydrogen reservoir is incorporated. Electrically superior to 4C35A.


    Original
    FX2505 4C35A. A4-18) FX2505, 4C35A 4C35 Thyratron thyratrons FX2505 BS448 equivalent thyratron tube operation thyratron tube PDF

    thyratron tube 5c22

    Abstract: CV6022 thyratron 5c22 5C22 thyratrons thyratron tube operation Thyratron 5c22 tube thyratron tube E2V Technologies
    Text: E2V Technologies 8503 Service Type CV6022 Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled triode thyratron, positive grid, for pulse operation. A hydrogen reservoir is incorporated. Electrically


    Original
    CV6022) thyratron tube 5c22 CV6022 thyratron 5c22 5C22 thyratrons thyratron tube operation Thyratron 5c22 tube thyratron tube E2V Technologies PDF

    e2v ccd60

    Abstract: CCD60 CCD60 Back Illuminated
    Text: CCD60 Back Illuminated Electron Multiplying CCD Sensor INTRODUCTION GENERAL DATA 2 The CCD60 is part of the new L3Vision range of products from e2v technologies. This device uses a novel output amplifier circuit that is capable of operating at an equivalent


    Original
    CCD60 CCD60BI, e2v ccd60 CCD60 Back Illuminated PDF

    CX1171T

    Abstract: thyratron thyratron tube operation
    Text: E2V Technologies CX1171T Three-Gap Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, three-gap, high voltage thyratron with ceramic/metal envelope, designed for operation in oil or air.


    Original
    CX1171T CX1171T, CX1171T thyratron thyratron tube operation PDF

    peltier schematic

    Abstract: fenwal thermistor peltier cooler schematic 196-302LAD-002
    Text: CCD60 Front Illuminated Peltier Pack Electron Multiplying CCD Sensor INTRODUCTION GENERAL DATA 2 The CCD60 is part of the new L3Vision range of products from e2v technologies. This device uses a novel output amplifier circuit that is capable of operating at an equivalent


    Original
    CCD60 CCD60FI peltier schematic fenwal thermistor peltier cooler schematic 196-302LAD-002 PDF

    Untitled

    Abstract: No abstract text available
    Text: CCD97-00 Back Illuminated 2-Phase IMO Series Electron Multiplying CCD Sensor INTRODUCTION The CCD97 is part of the L3VisionTM range of products from e2v technologies. This device uses a novel output amplifier circuit that is capable of operating at an equivalent output


    Original
    CCD97-00 CCD97 A1A-CCD97BI PDF

    Thyratron

    Abstract: CX1168 thyratron tube operation thyratron tube
    Text: E2V Technologies CX1168C Two-Gap Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, two-gap, high voltage thyratron with ceramic/ metal envelope, featuring low jitter, firing time and drift. The


    Original
    CX1168C 3573B CX1168C, Thyratron CX1168 thyratron tube operation thyratron tube PDF

    CX1154

    Abstract: Thyratron thyratrons thyratron tube operation thyratron diagram
    Text: E2V Technologies CX1154 Deuterium Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron with ceramic/metal envelope, featuring low jitter, firing time and drift. Suitable for


    Original
    CX1154 CX1154, CX1154 Thyratron thyratrons thyratron tube operation thyratron diagram PDF

    Untitled

    Abstract: No abstract text available
    Text: MityCCD High Performance Cameras MityCCD-E3011 APPLICATIONS • Embedded Instrumentation • Raman Spectroscopy • Low Light Imaging Applications • Portable Scientific Instrumentation • Astronomy FEATURES • High Performance Scientific Camera ƒ e2V 30-11 series


    Original
    MityCCD-E3011 ging-space-and-scientific-sensors/03-3011 CCD30-11 scientific-sensors/05-30-11DD-BI-NIMO-DIP ace-and-scientificsensors/Papers/ccdtn101 PDF

    KV 147

    Abstract: thyratron tube operation CX1174 thyratron 6890A E2V TECHNOLOGIES BR/BW1617F E2V TECHNOLOGIES BR/BW1617F SERIES thyratron tube schematic diagram heater thyratron diagram
    Text: E2V Technologies CX1174 Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron with ceramic/metal envelope, featuring low jitter, firing time and drift. Suitable for


    Original
    CX1174 CX1174, KV 147 thyratron tube operation CX1174 thyratron 6890A E2V TECHNOLOGIES BR/BW1617F E2V TECHNOLOGIES BR/BW1617F SERIES thyratron tube schematic diagram heater thyratron diagram PDF