    FPB33553 Search Results

    SF Impression Pixel

    FPB33553 Price and Stock

    Marathon Special Products FPB33553

    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Onlinecomponents.com FPB33553
    • 1 $177.43
    • 10 $156.07
    • 100 $156.07
    • 1000 $156.07
    • 10000 $156.07
    Buy Now

    FPB33553 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    250 amp breaker

    Abstract: JDL3 FPB33553 JJL36250 JLL36250 400kcmil Bradley
    Text: Product Data Sheet FPB33553 Power Distribution Block 335 Amps, 600 Volts AC/DC Wire Range: Line side: (1) 400kcmil - #6 AWG Load Side: (6) #2 - #14 AWG See tables below for SCCR wire ranges and multiple wire approvals. Electrical Ratings: • 335A copper wire, 270A aluminum wire (Based on NEC Table 310-16, 75°C columns)


    Original
    PDF FPB33553 400kcmil 250 amp breaker JDL3 FPB33553 JJL36250 JLL36250 Bradley

    FPB23570

    Abstract: ul508a FPB33588 UL1953 FPB23580 FPB33595 FPB23572 FPB23574
    Text: UL Listed Power Distribution Blocks The requirements of the National Electric Code NEC and UL508A now require many electrical panels to carry a Distribution Blocks are listed to UL1953. The feeder spacing requirements of UL508A are achieved with these blocks.


    Original
    PDF UL508A UL1953. FPB23570 FPB33588 125oC 130oC 100kA 100kA FPB23XXX FPB33588 UL1953 FPB23580 FPB33595 FPB23572 FPB23574

    145X282

    Abstract: No abstract text available
    Text: Power Distribution Blocks with SCCR and Feeder Spacing Short-Circuit Current Ratings and Feeder Spacing SCCR Information: The requirements of the National Electric Code NEC and UL508A now require many electrical panels to carry a Short Circuit Current Rating


    Original
    PDF UL508A 350MCM-6 145X282

    msc 1697

    Abstract: 486A-486B nec 08f DLS FT 031 awg 1608 F60A1B Transistor NEC 05F 6J200A3B KULKA 9-85 1432126
    Text: ENGINEERING CATALOG March, 2008 What’s New: • Flexible Stranded Wire UL Rating Information • SCCR with Fuses or Circuit Breakers • Datasheets on www.marathonsp.com • • • • FUSE HOLDERS POWER BLOCKS TERMINAL BLOCKS CUSTOM PRODUCTS www.marathonsp.com


    Original
    PDF 6137K/SK/7500/3-08/DBH msc 1697 486A-486B nec 08f DLS FT 031 awg 1608 F60A1B Transistor NEC 05F 6J200A3B KULKA 9-85 1432126

    ul508a

    Abstract: FPB33553 FPB33595 FPB23580 FPB23570 FPB23572 FPB23574 FPB33588 FPB23570CH
    Text: UL Listed Power Distribution Blocks The requirements of the 2005 National Electric Code NEC and UL508A now require many electrical panels to carry a Short Circuit Current Rating (SCCR). These new Power Distribution Blocks are listed to UL1953. The feeder spacing requirements of UL508A are


    Original
    PDF UL508A UL1953. E309401 FPB23570 FPB23572 FPB23574 FPB23580 100kA 100kA FPB33553 FPB33595 FPB33588 FPB23570CH

    1443557

    Abstract: JGL36250 JJL36250 1432555 1453586 JLL36250 1453552 1433553 1413400 FPB23570CH
    Text: 13300 Van Camp Road P.O. Box 468 Bowling Green, OH 43402 Standard Power Distribution Blocks With High Short-Circuit Current Ratings Marathon offers 600 Volt Power Distribution Blocks with high SCCR’s in response to new 2005 NEC and UL508A marking requirements


    Original
    PDF UL508A 1443557 JGL36250 JJL36250 1432555 1453586 JLL36250 1453552 1433553 1413400 FPB23570CH