SENSATA
Abstract: UL 943 GFCI yoda application note klixon
Text: PGFI Series 30 Amp Portable Series Cord GFCI / ELCI INTRODUCTION The LineGard 30 Amp Portable Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. Available with an operating voltage of 120 VAC, 208 VAC, 240 VAC or 277 VAC (UL 1053 compliant), this product can be integrated
|
Original
|
|
PDF
|
E41978
Abstract: ul498 GFCI e419 GFPOEMM UL943 Ul-498
Text: Product Datasheet - GFPOEMM Product Datasheet GFPOEMM - Circuit Guard Manual Set Portable GFCI Line Cords 15 & 20A 120V 15' GFCI power supply cord with stripped leads, manual set. Product Specifications GFCI Product Type Line Cord Type Industrial Amperage
|
Original
|
UL498
UL943
E41978
UL94V-0
E41978
GFCI
e419
GFPOEMM
Ul-498
|
PDF
|
GFCI schematic
Abstract: No abstract text available
Text: NCS37012 Product Preview Self Test Ground Fault Circuit Interrupter GFCI Description • 6.0 – 12 Volt Operation (120 − 480 V AC mains with the appropriate • • • • • • • • • • • series impedance) −40 to 85°C Very Low Power Consumption: <15 mW @ 5 V
|
Original
|
NCS37012
UL943
NCS37012/D
GFCI schematic
|
PDF
|
Untitled
Abstract: No abstract text available
Text: This document was generated on 03/05/2014 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: Status: Overview: Description: 130137-0234 Active Watertite Wet-Location Wiring Solutions Super-Safeway® GFCI Multiple Outlet FD Box, 1 NEMA 5-20 Duplex with Flip Lids,
|
Original
|
130137Series
3304GFA123
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FAN41501 Ground Fault Interrupter Self-Test Digital Controller Features Description • • Meets 2015 UL943 Self-Test GFCI Requirement Periodic EOL Testing without Compromising Normal GFCI Protection Built-in Noise Filters Reduce False EOL Signals
|
Original
|
FAN41501
UL943
90-Minute
com/dwg/MA/MA06A
dwg/PKG-MA06A
|
PDF
|
Untitled
Abstract: No abstract text available
Text: TESTER-GFI & CIRCUIT CALIB GFCI and Circuit Tester Cat No: 5708-C UPC No: 783310076407 Description • • • • Allows instant testing of GFCI receptacles or GFCI circuit breaker protected circuits Checks 120VAC grounded outlets for correct/incorrect wiring
|
Original
|
5708-C
120VAC
|
PDF
|
Untitled
Abstract: No abstract text available
Text: PowerVerter 1250W Utility/Work Truck Inverter/Charger with 2 Outlets MODEL NUMBER: UT1250UL Highlights 12V DC or 120VAC input; 120VAC output; 2 GFCI protected outlets 1250 watts continuous, 1875 watts OverPower and 2500 watts DoubleBoost inverter output
|
Original
|
UT1250UL
120VAC
UT1250UL
BP-260
com/sku/UT1250UL.
|
PDF
|
Untitled
Abstract: No abstract text available
Text: www.greenlee.com ESSENTIAL ELECTRICAL Kits TK-30A • TK-30AGFI MULTIMETER Measure AC/DC voltage up to 600V NON-CONTACT VOLTAGE DETECTOR Safely detect AC Voltage RECEPTACLE TESTER Ensure sockets are wired correctly and test Ground Fault Circuit Interrupter GFCI
|
Original
|
TK-30A
TK-30AGFI
TK-30A
DM-25)
GT-11)
GT-10)
|
PDF
|
Untitled
Abstract: No abstract text available
Text: ELECTRICAL KIT,GFCI TK-30GFI Electrical Kit, GFCI Description Includes DM-20, GT-11, GT-10GFI Specifications • • • Includes : ƕ DM-20 Digital Multimeter ƕ GT-11 Voltage tester ƕ GT-10GFI Polarity Cubes Model : TK-30GFI Type : GFCI Cat No: TK-30GFI
|
Original
|
TK-30GFI)
DM-20,
GT-11,
GT-10GFI
DM-20
GT-11
GT-10GFI
TK-30GFI
|
PDF
|
Untitled
Abstract: No abstract text available
Text: PowerVerter 2000W Utility/Work Truck Inverter/Charger with 2 Outlets MODEL NUMBER: UT2012UL Highlights 12V DC or 120VAC input; 120VAC output; 2 GFCI protected outlets 2000 watts continuous, 3000 watts OverPower and 4000 watts DoubleBoost inverter output
|
Original
|
UT2012UL
120VAC
UT2012UL
BP-260
com/sku/UT2012UL.
|
PDF
|
Untitled
Abstract: No abstract text available
Text: PGFI Series 15 Amp Plug Series GFCI / ELCI INTRODUCTION The LineGard 15 Amp Plug Series is a ground fault circuit interrupter designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. The PGFP product is rated for 15 amps at 120 VAC and available in either manual safe start or
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: This document was generated on 03/05/2014 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: Status: Overview: Description: 130137-0237 Active Watertite Wet-Location Wiring Solutions Watertite® GFCI Multiple Outlet FD Box, 1 NEMA 5-20 Duplex with Flip Lids, 1.83m
|
Original
|
130137Series
3304GFL123
|
PDF
|
Untitled
Abstract: No abstract text available
Text: This document was generated on 03/05/2014 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: Status: Overview: Description: 130138-0083 Active Watertite Wet-Location Wiring Solutions Watertite® Multiple Outlet Pendant Box, GFCI, 1 NEMA 5-15 Duplex with Flip Lids,
|
Original
|
130138Series
70W47A143GF
|
PDF
|
Untitled
Abstract: No abstract text available
Text: This document was generated on 03/05/2014 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: Status: Overview: Description: 130137-0227 Active Series image - Reference only Watertite Wet-Location Wiring Solutions Watertite® GFCI Multiple Outlet FD Box with Ground Continuity Monitor, 1 NEMA
|
Original
|
130137Series
610/kg
3301GGFL143
|
PDF
|
|
SOT89 52 10A
Abstract: s6x8ts sot 223 52 10a
Text: Teccor brand Thyristors EV Series 0.8 Amp Sensitive SCRs SxX8xSx Series RoHS Description New device series offers high static dv/dt and lower turn off tq sensitive SCR with its small die planar construction design. It is specifically designed for GFCI (Ground Fault
|
Original
|
OT-223)
OT-89)
OT-223
OT-89
OT223
SOT89 52 10A
s6x8ts
sot 223 52 10a
|
PDF
|
GFCI schematic
Abstract: ON-MCR08 scr driver ic for rectifier 3 phase
Text: NCS37000 Ground Fault Circuit Interrupter GFCI Description Features • 6.0 – 12 Volt Operation (120 − 480 V AC mains with the appropriate • • • • • • • • • • series impedance) −40 to 85°C Very Low Power Consumption: <5 mW @ 5 V
|
Original
|
NCS37000
UL943
QFN16
TSSOP-20
NCS37000/D
GFCI schematic
ON-MCR08
scr driver ic for rectifier 3 phase
|
PDF
|
Untitled
Abstract: No abstract text available
Text: This document was generated on 09/10/2013 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: Status: Overview: Description: 130135-0315 Active Outlet Boxes Watertite GFCI Multiple Outlet Box with Open Neutral Relay, 6 NEMA 5-20 Outlets
|
Original
|
LR6837
130135Series
|
PDF
|
Untitled
Abstract: No abstract text available
Text: This document was generated on 09/10/2013 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: Status: Overview: Description: 130135-0256 Active Outlet Boxes Super-Safeway Angled GFCI Outlet Box, F3 3/4" Cord Grip Body, Including NEMA 5-20 GFCI & Duplex Receptacles with Flip Lids
|
Original
|
130135Series
|
PDF
|
GFCI outlet
Abstract: No abstract text available
Text: This document was generated on 08/13/2012 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: Status: Overview: Description: 130153-0089 Active Outlet Boxes Safe-T-Check User Attachable GFCI Right-Angle Plug, Manual Reset, NEMA 5-15, 15A, 120V
|
Original
|
920/g
130153Series
GFCI outlet
|
PDF
|
Untitled
Abstract: No abstract text available
Text: This document was generated on 01/13/2014 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: Status: Overview: Description: 130135-0242 Active Outlet Boxes Super-Safeway GFCI Multiple Outlet Box, Open Neutral Relay, 3 NEMA 5-20 Single
|
Original
|
670/kg
130135Series
32WG20A123
|
PDF
|
Untitled
Abstract: No abstract text available
Text: This document was generated on 03/05/2014 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: Status: Overview: Description: 130137-0180 Active Watertite Wet-Location Wiring Solutions Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, 1 NEMA 5-15 GFCI
|
Original
|
LR6837
000/g
130137Series
3080-GFI
|
PDF
|
Untitled
Abstract: No abstract text available
Text: This document was generated on 03/05/2014 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: Status: Overview: Description: 130137-0163 Active Watertite Wet-Location Wiring Solutions Watertite® Multiple Outlet Box, Extended Depth, 1 NEMA 5-15 Manual reset GFCI
|
Original
|
LR6837
130137Series
070W-GFI
|
PDF
|
Untitled
Abstract: No abstract text available
Text: This document was generated on 09/09/2013 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: Status: Description: 130102-0150 Active Super-Safeway Rubber Hand Lamp with 300W Open End Guard W 15.24m 50.0' 16/3 SOOW, In-line GFCI Documents:
|
Original
|
LR85374
130102Series
111B163IN
|
PDF
|
Untitled
Abstract: No abstract text available
Text: This document was generated on 01/13/2014 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: Status: Overview: Description: 130135-0250 Active Outlet Boxes Super-Safeway Angled GFCI Outlet Box, Feed-Thru, F3 3/4" Cord Grip Body, Including NEMA 5-15 GFCI & Duplex Receptacles with Flip Lids and 7.62m (25.0' )
|
Original
|
Physic29
890/g
130135Series
3320FA123
|
PDF
|