Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MERSEN Search Results

    MERSEN Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    LC1-D09 01

    Abstract: ED63A 8536SC03
    Text: Mersen UltraSafeTM Fuse Modules have a unique, compact design suited for use with 45mm wide IEC contactors and motor starters. The USFMCC I has a stand-alone short circuit current rating (SCCR) of 200kA. Mersen Class CC motor protection fuses offer time delay characteristics in a compact body with a 200kA interrupting rating.


    Original
    PDF 200kA. 200kA UL508A 600VAC, CHT-SCCRUSFM-01 LC1-D09 01 ED63A 8536SC03

    CNL500

    Abstract: No abstract text available
    Text: Forklift Truck Fuses Mersen Forklift Truck and Battery Isolator fuses are specially designed for the heavy duty loads associated with DC battery powered equipment such as forklift trucks, hand trucks, motorized work platforms, and other DC battery operated systems.


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: New ratings now available! HP6J 600V DC Class J Photovoltaic Fuses About the HP6J Fuse Mersen’s HP6J photovoltaic PV fuse series was engineered and designed specifically for the protection of photovoltaic systems. Its enhanced fuse construction makes it ideal for continuous temperature and current cycling withstand adding to


    Original
    PDF 600VDC 61016J* 62001J 62011J* 64031J 64011J* 6631J 6611J*

    9F61BWW460

    Abstract: 9F60BHH905 9F60BDD001 transformer e33
    Text: Potential Transformer Amp-Trap and 9F60 Series PT Fuses 0.625kV – 2.4kV – 2.75kV – 4.8kV – 5.0kV – 5.5kV – 7.2kV – 8.25kV and 15.5kV ferrule mounted fuses: Mersen PT fuses are current-limiting fuses with high interrupting rating, used for the


    Original
    PDF 625kV 9F60BHH905 9F61ADG101 9F60BHH001 9F60BHH002 9F60BHH003 120kA 9F61BWW460 9F61BNW450 9F61ADJ101 9F61BWW460 9F60BHH905 9F60BDD001 transformer e33

    9F60DMH905

    Abstract: No abstract text available
    Text: Transformer Protection Amp-Trap CS-3 Series and 9F60/9F62 Series 2.75kV, 5.5kV, 8.25kV, 15.5kV, 25.8kV and 38kV Ferrule Mounted Fuses Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can


    Original
    PDF 9F60/9F62 A155F1D0R0-65E A155F1D0R0-100E A155F2D0R0-175E A155F2D0R0-200E A155F2D0R0-150E A155F2D0R0-125E A155F1D0R0-80E 9F60DMH905

    Untitled

    Abstract: No abstract text available
    Text: TGL, TGN, TGS Telecommunications Fuses Mersen Telecommunications fuses are specially designed for the protection of telecommunications equipment which includes telephone switching equipment, rectifiers, distribution switching panels, battery back-up modules, power supplies and


    Original
    PDF 170VDC 170VDC, 100kA 1-600A TGS25 TGS30 TGS40 TGS50 TGS10 TGS60

    ETI fuse

    Abstract: No abstract text available
    Text: HP10NH1 1000V DC Size NH1 Photovoltaic Fuses About the HP10NH1 Fuse Mersen’s HP10NH1 photovoltaic PV fuse series was engineered and designed specifically for the protection of photovoltaic systems. Its enhanced fuse construction makes it ideal for continuous temperature and current cycling withstand adding to


    Original
    PDF HP10NH1 1000VDC HP10NH1GPV50 Z1028283 HP10NH1GPV63 A1028284 HP10NH1GPV80 ETI fuse

    mersen

    Abstract: inventory
    Text: Get Control of Your Inventory and Costs Fact Sheet Fuse Control TM Mersen’s Fuse Control program is a powerful combination of circuit protection products and services designed to help you get control of your plant inventory, operating costs, code compliance and


    Original
    PDF 300kA, FS-FC-002 mersen inventory

    HP10M15

    Abstract: US101HEL HP10M10 HP10M20 HP10M4 Photovoltaic US101IHEL HP10M12 HP10M7 HP10M5
    Text: HP10M 1000VDC Photovoltaic Fuses Engineered to protect photovoltaic applications Mersen’s HP10M photovoltaic PV fuse series was engineered and designed specifically for the protection of photovoltaic systems. Its enhanced fuse construction makes it ideal for continuous temperature and current cycling withstand adding to


    Original
    PDF HP10M 1000VDC HP10M, 1000VDC HP10M1 HP10M7 HP10M8 HP10M10 HP10M15 US101HEL HP10M10 HP10M20 HP10M4 Photovoltaic US101IHEL HP10M12 HP10M7 HP10M5

    PCF30/50-H

    Abstract: No abstract text available
    Text: PCF Fast-Acting PC Mount Fuses Fast-acting fuses for direct mounting on printed circuit boards. Mersen’s PCF series of fast-acting direct-mountable fuses addresses the increasing need for electrical protection at the PC board as current and voltage requirements


    Original
    PDF PCF10-S PCF12-S PCF15-S PCF20-S PCF25-S PCF30-S PCF30-R PCS40-R PCT30-R PCF30-H PCF30/50-H

    Untitled

    Abstract: No abstract text available
    Text: Capacitor Protection Amp-Trap and 9F60 Series Medium voltage capacitor fuses: Mersen capacitor fuses are designed to ANSI C37-41. They are current-limiting operating without noise or discharge and are designed to be used indoors in a general purpose enclosure or outdoors in a weatherproof enclosure. These are nondisconnecting fuses requiring the use of a disconnect switch. These capacitor fuses


    Original
    PDF C37-41. A430C6-75 A430C8-75 A430C10-75 A430C12-75 A430C18-75 A430C20-75 A430C25-75 A430C30-75 A430C35-75

    Untitled

    Abstract: No abstract text available
    Text: A4BX Welder Protectors Welder protectors Mersen Welder Protectors are special purpose limiters used to provide isolation of faulted welding equipment and protection for the cable drop supplying the welder. Welder Protectors have a high thermal capacity and are less affected by high ambient


    Original
    PDF A4BX100-150 A4BX125-150 A4BX150-150 A4BX200-150 A4BX200-150J A4BX225-1504BX600-150 600VAC 200kA

    S 20 KV 431

    Abstract: No abstract text available
    Text: Capacitor Protection Amp-Trap and 9F60 Series Medium voltage capacitor fuses: Mersen capacitor fuses are designed to ANSI C37-41. They are current-limiting operating without noise or discharge and are designed to be used indoors in a general purpose enclosure or outdoors in a weatherproof enclosure. These are nondisconnecting fuses requiring the use of a disconnect switch. These capacitor fuses


    Original
    PDF C37-41. 9F60RJD040 9F60RJF015 9F60RJF040 9F60RJF025 S 20 KV 431

    9F62FCB300

    Abstract: A055F1D0R0100E A055F2D0R0-450E
    Text: Transformer Protection Amp-Trap CS-3 Series and 9F60/9F62 Series 2.75kV, 5.5kV, 8.25kV, 15.5kV, 25.8kV and 38kV Ferrule Mounted Fuses Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can


    Original
    PDF 9F60/9F62 9F60FJD040 9F60FJD030 9F60DJD025 9F60DJD020 9F60DJD015 9F60DJD005 9F60DJD003 9F60DJD002 9F60DJD001 9F62FCB300 A055F1D0R0100E A055F2D0R0-450E

    Untitled

    Abstract: No abstract text available
    Text: A60C Low Voltage Capacitor Fuses 600V Low Voltage Capacitor Fuses Mersen low voltage capacitor fuses provide advanced safety for power correction and harmonic filtering equipment. A capacitor fuse isolates a shorted capacitor before it can damage surrounding equipment or personnel. Typical capacitor failures occur


    Original
    PDF A60C35-121TI A60C40-121 A60C40-121TI A60C50-121 A60C50-121TI A60C60-121 A60C60-121TI A60C75-121TI A60C80-121 A60C80-121TI

    SP670PV

    Abstract: STP1000YPVM SP350PV IEC 61643-1 SP745PV STP600YPVM microswitch subminiature PV charge controllers 600C 4047 BE
    Text: Data Sheet Surge-Trap PV Pluggable SPD About the Surge-Trap PV Pluggable SPD This Surge-Trap SPD provides advanced overvoltage protection to photovoltaic systems by utilizing Mersen’s patented TPMOV design. The Surge-Trap Pluggable base is designed to be mounted on 35mm DIN-rail


    Original
    PDF STP600YPVM STP1000YPVM STP1200YPVM DS-STP-PV-002 SP670PV SP350PV IEC 61643-1 SP745PV microswitch subminiature PV charge controllers 600C 4047 BE

    Untitled

    Abstract: No abstract text available
    Text: Capacitor Protection Amp-Trap and 9F60 Series Medium voltage capacitor fuses: Mersen capacitor fuses are designed to ANSI C37-41. They are current-limiting operating without noise or discharge and are designed to be used indoors in a general purpose enclosure or outdoors in a weatherproof enclosure. These are nondisconnecting fuses requiring the use of a disconnect switch. These capacitor fuses


    Original
    PDF C37-41. A300C95-20 A300C100-20 A300C115-20 A300C125-20 A300C130-20 A300C150-20 A300C175-20 A300C50-60 A300C60-60

    Untitled

    Abstract: No abstract text available
    Text: Motor Protection Amp-Trap and 9F60 Series 2.4kV, 2.54kV, 4.8kV, 5.08kV and 7.2kV Ferrule mounted fuses: Mersen R-Rated fuses are current-limiting, high interrupting rating fuses intended for the short circuit protection of medium voltage motors and motor controllers.


    Original
    PDF 9F60LCL309 9F60MCL324 9F60MCL318 9F60LCL312 9F60LCL304 9F60LCL303 9F60MCB518 9F60LCB512 9F60LCB504 9F60LCB503

    A155B

    Abstract: No abstract text available
    Text: Transformer Protection Amp-Trap and 9F62 Bolt-In Series 5.0kV, 5.5kV, 7.2kV, 8.25kV, and 15.5kV Bolt-In fuses: Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can


    Original
    PDF 9F62KED300 9F61AHG001 9F61CHL009 A155B

    30321 mersen

    Abstract: No abstract text available
    Text: DCT Special Purpose Midget Fuses Mersen DCT fuses were developed to meet requirements coming from new applications such as protection of photovoltaic cells, multi meters and compact on board traction equipment for auxiliary circuits. This high performance DC fuse in its


    Original
    PDF DCT10-2 DCT12-2 DCT15-2 DCT20-2 DCT25-2 DCT30-2 E60314 10x38mm) 30321 mersen

    30321 mersen

    Abstract: No abstract text available
    Text: VSP MOV Protector Fuse Surge Suppression Fuses Mersen surge suppression fuses are specially designed to address the protection of SPD systems. Our surge suppression fuses have been specially designed to withstand 8x20 µSec surge pulses without opening, allowing the SPD system to


    Original
    PDF 600VAC, 200kA 5-100kA 60305J 60315J 60325J 60306J 60316J 60326J 60307J 30321 mersen

    Untitled

    Abstract: No abstract text available
    Text: A2Y/A6Y Form 600 Form 600 fuses Mersen Form 600 fuses are the original current-limiting fuses, pre-dating all the standards. Their 500V DC rating through 600A is a useful feature for special fusing applications. Form 600 fuses provide a high degree of current limitation in AC and DC


    Original
    PDF A2Y200-3 A6Y200-3 A2Y200-4 A6Y200-4 A6Y200-5 A6Y225-3 A6Y225-4 VAC/500 25-600A 50-1200A

    HP6M

    Abstract: ELEVATOR Elevator motors Ferraz Shawmut HP10M INVERTER TRANSFORMERS design COMBINER BOX wiring shunt trip Ferraz Shawmut SPD elevator inverter
    Text: Circuit Protection Products Electricity runs the world. At Mersen formerly Ferraz Shawmut , we keep it safe and reliable with a comprehensive range of products and services to protect your products and systems and the people who use them. Explore what we can do for you!


    Original
    PDF LC-PRDCTS-001 HP6M ELEVATOR Elevator motors Ferraz Shawmut HP10M INVERTER TRANSFORMERS design COMBINER BOX wiring shunt trip Ferraz Shawmut SPD elevator inverter

    Untitled

    Abstract: No abstract text available
    Text: gl-gG, aM NH Dimension Knife-Blade Fuse-Links NH Dimension Knife-Blade fuse-links, fuse bases, and accessories Mersen NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator


    Original
    PDF 120kA. 5-100A 25-315A 250/300A 15-425A 00-800A