Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    POLYGYR Search Results

    POLYGYR Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    polygyr

    Abstract: QAA24 polygyr RWF 32 polygyr rwf siemens RWF qaa25 RKN8 siemens air temperature sensors QAA24 rwi65.01 RWF 32
    Text: 1 . . . . . . . . . 1721P020 1721P010 721 QAA24 QAA25QAA27 Room Temperature Sensors QAA24.27 with and without setpoint adjuster Use In heating, ventilating and air conditioning plants, especially where a high level of comfort is required. Major field of application:


    Original
    PDF 1721P020 1721P010 QAA24 QAA25. QAA27 QAA24. QAA25 QAA26 polygyr QAA24 polygyr RWF 32 polygyr rwf siemens RWF qaa25 RKN8 siemens air temperature sensors QAA24 rwi65.01 RWF 32

    polygyr

    Abstract: QBE61 qbe61.2 Landis PN40 water differential pressure sensor chilled water system landis and staefa Differential Pressure siemens siemens humidity sensor
    Text: 1 Differential Pressure Sensor 915 QBE61.2-dp0,5 This sensor delivering an active measuring signal of DC 0.10 V and works on a AC 24 V operating voltage. Measuring ranges between 0 and 0.5 bar differential pressure. Application Sensing of differential pressure in heating, ventilating and air conditioning plants.


    Original
    PDF QBE61 1915G01 CM1N1915E 1901M02E 1915M01 CM1N3463E polygyr qbe61.2 Landis PN40 water differential pressure sensor chilled water system landis and staefa Differential Pressure siemens siemens humidity sensor

    polygyr

    Abstract: polygyr RWF 32 SM220-SR SM24S Motor Control Center wiring diagram abb SM24-SR90 SM24-SR rwf 61.3 polygyr RWF 1-14 staefa RS
    Text: B C Actuators for heating, ventilation, air-conditioning Product Information Damper actuators SM i0028811 2. SM-4 B C LM NM SM AM GM LF AF R 4 Nm 8 Nm 15 Nm 18 Nm 30 Nm 4 Nm 15 Nm – – – – – 0.8 m2 1.5 m2 3 m2 3.6 m2 6 m2 0.8 m2 3 m2 For dampers Spring return


    Original
    PDF i0028811 i0099805 TR-80060 ENG-93001-93223-04 02-1M polygyr polygyr RWF 32 SM220-SR SM24S Motor Control Center wiring diagram abb SM24-SR90 SM24-SR rwf 61.3 polygyr RWF 1-14 staefa RS

    VOC sensor

    Abstract: polygyr SIEMENS gas QPA63.1 ARG64 QPA63.1 co2 sensor QPA63 Siemens duct temperature sensor RWI65 Siemens duct temperature controller
    Text: 1 QPA63.1 . . . . . . . . 1958P03 1958P02 1958P01 958 QPA63.2 QPA63.1/AUS QPA63. CO2 /VOC Sensors Sensors designed for acquiring indoor air quality in rooms or air ducts. Microprocessor-based units consisting of a selective photo-acoustic CO2 sensor and a VOC1 sensor with a heated stannic dioxide semiconductor.


    Original
    PDF QPA63 1958P03 1958P02 1958P01 QPA63. CM1N1958E VOC sensor polygyr SIEMENS gas QPA63.1 ARG64 QPA63.1 co2 sensor Siemens duct temperature sensor RWI65 Siemens duct temperature controller

    SM220-SR

    Abstract: polygyr rwf polygyr SM24-SR polygyr RWF 32 SM24-SR90 SM24-SRP siemens RWF SM220 staefa RWF
    Text: B C Actuators for heating, ventilation, air-conditioning Product Information Damper actuators SM i0028811 2. SM-3 B C LM NM SM AM GM LF AF 4 Nm 8 Nm 15 Nm 18 Nm 30 Nm 4 Nm 15 Nm – – – – – 0.8 m2 1.5 m2 3 m2 3.6 m2 6 m2 0.8 m2 3 m2 For dampers Spring return


    Original
    PDF i0028811 i0099805 m0026805 ENG-93001-93223-07 99-2M SM220-SR polygyr rwf polygyr SM24-SR polygyr RWF 32 SM24-SR90 SM24-SRP siemens RWF SM220 staefa RWF

    LG-Ni1000

    Abstract: temperature sensor Landis Ni 1000 polygyr Siemens Ni1000 temperature sensor staefa landis ni1000 lg-ni 1000 LG-Ni QAA64
    Text: 1 Room Temperature Sensor 722 QAA64 vandalproof though concealed mounting Use Acquisition of room temperature in spaces where the detector needs to be protected against damage or destruction by people. Such spaces are public buildings like schools, administrative buildings, multipurpose halls, etc.


    Original
    PDF QAA64 QAA64 LG-Ni1000 1722G01 1722M01 CM1N1722E LG-Ni1000 temperature sensor Landis Ni 1000 polygyr Siemens Ni1000 temperature sensor staefa landis ni1000 lg-ni 1000 LG-Ni

    qfm64

    Abstract: RWF61 polygyr polygyr RWF61 rwf61 siemens Siemens duct temperature controller polygyr 3401 rwf61.20 enthalpy Pt 1000 sensor siemens
    Text: 1 899 1899P01 . . . . . . . . . Transducer for absolute Humidity and Enthalpy AQF61.1 Microprocessor-based converter to calculate absolute humidity, enthalpy and enthalpy differential. Application • In ventilating and air conditioning plants. • To measure, regulate, control and display absolute humidity, enthalpy or enthalpy


    Original
    PDF 1899P01 AQF61 ARG81 QFM64 RWF61. qfm64 RWF61 polygyr polygyr RWF61 rwf61 siemens Siemens duct temperature controller polygyr 3401 rwf61.20 enthalpy Pt 1000 sensor siemens

    qbe*61.1

    Abstract: QBE61 landis qbe61.1-p20 polygyr QBE61.1 pressure sensor landis qbe61,1 p20 staefa Landis siemens r134a QBE61 p2
    Text: 1 Pressure Detectors 901 QBE61.1. Active pressure detector delivering a DC 0.10 V measuring signal and operating on AC 24 V. There are five different versions available, with measuring ranges between 0 and 40 bar. Application Measuring and sensing of overpressure in heating, ventilating and air conditioning


    Original
    PDF QBE61 CM1N1901E 1901G01 1901M03E 1901M02E 1901M01 CM1N3461E qbe*61.1 landis qbe61.1-p20 polygyr QBE61.1 pressure sensor landis qbe61,1 p20 staefa Landis siemens r134a QBE61 p2