Untitled
Abstract: No abstract text available
Text: Temperature measurement Accessories thermowell THW-6-DN25K-A4-L150 • ■ ■ Thermowell for temperature probes 6 mm diameter, TP series For food and pharmaceutical processing Surface roughness Ra > 0.8 µm General description Thermowells protect the probes against aggressive media and high pressures. Direct
|
Original
|
THW-6-DN25K-A4-L150
DIN11851
2013-07-14T00
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measurement Accessories thermowell THW-3-TRI3/4-A4-L035 • ■ ■ Thermowell for mounting TS203 probes For food and pharmaceutical processing Surface roughness Ra > 0.8 µm General description Thermowells are used for unpressurized mounting of probes. Direct contact with the
|
Original
|
THW-3-TRI3/4-A4-L035
TS203
2013-07-14T00
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measurement Accessories thermowell THW-3-TRI3/4-A4-L050 • ■ ■ Thermowell for mounting TS203 probes For food and pharmaceutical processing Surface roughness Ra > 0.8 µm General description Thermowells are used for unpressurized mounting of probes. Direct contact with the
|
Original
|
THW-3-TRI3/4-A4-L050
TS203
2013-07-14T00
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measurement Accessories thermowell THW-6-TRI3/4-A4-L100 • ■ ■ Thermowell for temperature probes 6 mm diameter, TP series For food and pharmaceutical processing Surface roughness Ra > 0.8 µm General description Thermowells protect the probes against aggressive media and high pressures. Direct
|
Original
|
THW-6-TRI3/4-A4-L100
2013-07-14T00
D-45472
|
PDF
|
D-150-9133
Abstract: Raychem cable 10612 Raychem cable 10613 10613 Raychem d1509133 Raychem cable 10614 10613 Raychem bend radius raychem JOINT procedure J-STD-006 RK-6008
Text: SPECIFICATION CONTROL DRAWING Tyco Electronics Corporation 300 Constitution Drive, Menlo Park, CA. 94025, U.S.A. TITLE: Raychem DOCUMENT NO.: Unless otherwise specified dimensions are in millimeters. [Inches dimensions are shown in brackets] D-150-9133 ROUGHNESS IN
|
Original
|
MIL-STD-1553B
D-150-9133
27-Sept-00
D000423
HPDS-0519.
RPIP-600-12.
D-150-9133
Raychem cable 10612
Raychem cable 10613
10613 Raychem
d1509133
Raychem cable 10614
10613 Raychem bend radius
raychem JOINT procedure
J-STD-006
RK-6008
|
PDF
|
CALCULATION
Abstract: No abstract text available
Text: E Cores General Information 4 Cores with toleranced air gap The following tolerances for dimension „g“ apply to all E cores: Dimension g mm g < 0,10 mm 0,10 mm ≤ g < 0,5 g ≥ 0,5 Tolerance mm ± 0,01 ± 0,02 ± 0,05 As is the case with ungapped cores, a certain degree of roughness cannot be avoided on the
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measurement Accessories thermowell THW-6-TRI3/4-A4-L050 • ■ ■ Thermowell for temperature probes 6 mm diameter, TP series For food and pharmaceutical processing Surface roughness Ra > 0.8 µm General description Thermowells protect the probes against aggressive media and high pressures. Direct
|
Original
|
THW-6-TRI3/4-A4-L050
2013-07-14T00
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measurement Accessories thermowell THW-3-TRI3/4-A4-L250 • ■ ■ Thermowell for mounting TS203 probes For food and pharmaceutical processing Surface roughness Ra > 0.8 µm General description Thermowells are used for unpressurized mounting of probes. Direct contact with the
|
Original
|
THW-3-TRI3/4-A4-L250
TS203
2013-07-14T00
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measurement Accessories thermowell THW-3-DN25K-A4-L250 • ■ ■ Thermowell for mounting TS203 probes For food and pharmaceutical processing Surface roughness Ra > 0.8 µm General description Thermowells are used for unpressurized mounting of probes. Direct contact with the
|
Original
|
THW-3-DN25K-A4-L250
TS203
DIN11851
2013-07-14T00
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measurement Accessories thermowell THW-3-DN25K-L035 • ■ ■ Thermowell for mounting TS203 probes For food and pharmaceutical processing Surface roughness Ra > 0.8 µm General description Thermowells are used for unpressurized mounting of probes. Direct contact with the
|
Original
|
THW-3-DN25K-L035
TS203
DIN11851
2013-07-14T00
D-45472
|
PDF
|
ARALDITE 103 hy 956
Abstract: ARALDITE D AY 103 epcos etd34 ARALDITE D HY 956 ay 103 mit hy 956 araldite ay 105-1 ARALDITE HY 956 ARALDITE D araldite ciba ARALDITE standard epoxy adhesive
Text: Processing Notes Processing notes 1 Gapped and ungapped ferrite cores Even with the best grinding methods known today, a certain degree of roughness on ground surfaces cannot be avoided, so that the usual term “without air gap” or “ungapped” does not imply no
|
Original
|
|
PDF
|
C1207
Abstract: paste resistor thick film R2210 R2211 quan-tech R2202 R2216 SC414 R-2215 inspection report
Text: CLEC Group R-2200 Specification 1. Scope: This specification applies to resistive paste for thick film circuit and chip resistor. 2. General: 2.1)Transportation method: By Post, Railway, Airways etc 2.2)Operating conditions: Substrate:96% alumina,surface roughness 3-5 m
|
Original
|
R-2200
Substrate96%
5-15min
100-200Pa
SC4-14/6R)
10rpm,
R-2200
C1207
paste resistor thick film
R2210
R2211
quan-tech
R2202
R2216
SC414
R-2215
inspection report
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measurement Accessories thermowell THW-3-TRI3/4-A4-L100 • ■ ■ Thermowell for mounting TS203 probes For food and pharmaceutical processing Surface roughness Ra > 0.8 µm General description Thermowells are used for unpressurized mounting of probes. Direct contact with the
|
Original
|
THW-3-TRI3/4-A4-L100
TS203
2013-07-14T00
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measurement Accessories thermowell THW-3-DN25K-A4-L100 • ■ ■ Thermowell for mounting TS203 probes For food and pharmaceutical processing Surface roughness Ra > 0.8 µm General description Thermowells are used for unpressurized mounting of probes. Direct contact with the
|
Original
|
THW-3-DN25K-A4-L100
TS203
DIN11851
2013-07-14T00
D-45472
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Temperature measurement Accessories thermowell THW-6-DN25K-A4-L250 • ■ ■ Thermowell for temperature probes 6 mm diameter, TP series For food and pharmaceutical processing Surface roughness Ra > 0.8 µm General description Thermowells protect the probes against aggressive media and high pressures. Direct
|
Original
|
THW-6-DN25K-A4-L250
DIN11851
2013-07-14T00
D-45472
|
PDF
|
transistor 764
Abstract: Ebenheit 2902 powersemiconductor
Text: from Europe for the World Application Note European PowerSemiconductor and Electronics Company Heat Sink Specification for IGBT Modules Condition of Contact Area of Modules Footprint Roughness Planarity of Module RZ [µm] [µm] 130 x 140 10 - 15 < 30 140 x 190
|
Original
|
D-59581
transistor 764
Ebenheit
2902
powersemiconductor
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measurement Accessories thermowell THW-3-DN25K-A4-L050 • ■ ■ Thermowell for mounting TS203 probes For food and pharmaceutical processing Surface roughness Ra > 0.8 µm General description Thermowells are used for unpressurized mounting of probes. Direct contact with the
|
Original
|
THW-3-DN25K-A4-L050
TS203
DIN11851
2013-07-14T00
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measurement Accessories thermowell THW-6-TRI3/4-A4-L250 • ■ ■ Thermowell for temperature probes 6 mm diameter, TP series For food and pharmaceutical processing Surface roughness Ra > 0.8 µm General description Thermowells protect the probes against aggressive media and high pressures. Direct
|
Original
|
THW-6-TRI3/4-A4-L250
2013-07-14T00
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measurement Accessories thermowell THW-3-DN25K-A4-L150 • ■ ■ Thermowell for mounting TS203 probes For food and pharmaceutical processing Surface roughness Ra > 0.8 µm General description Thermowells are used for unpressurized mounting of probes. Direct contact with the
|
Original
|
THW-3-DN25K-A4-L150
TS203
DIN11851
2013-07-14T00
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measurement Accessories thermowell THW-3-TRI3/4-A4-L150 • ■ ■ Thermowell for mounting TS203 probes For food and pharmaceutical processing Surface roughness Ra > 0.8 µm General description Thermowells are used for unpressurized mounting of probes. Direct contact with the
|
Original
|
THW-3-TRI3/4-A4-L150
TS203
2013-07-14T00
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: NO. NAME MATERIAL FINISH Q, TY 01 Core tube 01 TPE/TPR Black 02 SMA 180° Male Brass G o ld e n plating 01 7 6 .5 + 2 X oo CDii o o o o o w en « -( è CUSTOMER1S MODEL PARTS NUMBER ^ - — J Third angle projection TOLERANCE RF A n te n n T e c h n o lo g y C o rp SURFACE ROUGHNESS
|
OCR Scan
|
900/1800MHZ
EA-1011
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Thermal Printheads Serial type •F o r high speed printing on bond paper Specal under-glaze layer and heat element construction allows printing on a rough surfaced media up to 2 sec surface roughness . Part No. Dot density ( d o ts /in c h ) Effective print width
|
OCR Scan
|
NC6436-A1
KV6418-A1
KV6420-A1
KV2001-A1
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Thermal Printheads Serial type #For high speed printing on bond paper Special under-glaze layer and heat element construction allows printing on a rough surfaced media up to 2 sec surface roughness . Part No. NC6436-A1* Dot density (d o ts /in c h ) Effective print width
|
OCR Scan
|
NC6436-A1*
KV6418-A1
KV6420-A1
KV2001-A1
|
PDF
|
Untitled
Abstract: No abstract text available
Text: OF CONTACT. £3 DO NOT SCALE PDM: Drawn JS 20-Apr-00 Material: Checked Engiilineer. 3rd ANGLE PROJECTION Manufact. Surface Roughness Assembly B RE-DRAWN 20-Apr-00 Re* DCN/ECN or Description Date Total Surface Area ITT Cannon RF PRODUCTS Treatment: Quality
|
OCR Scan
|
20-Apr-00
W58-100-2029-01
|
PDF
|