Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SONTAY Search Results

    SONTAY Datasheets (2)

    Part ECAD Model Manufacturer Description Curated Datasheet Type PDF
    GS-AQ911 Sontay Space air quality transmitter Original PDF
    LS-541 Sontay Liquid level float switch Original PDF

    SONTAY Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    split core

    Abstract: PM-H722LC 7353 transistor H722 PM-H722HC PM-H922LC
    Text: Data Sheet Ref: 90501177 Issue: 5.1 PM-Hx22 0-5Vdc Current transducer www.sontay.com Technical Overview The PM-Hx22 series of current transducers can be used to monitor motors, pumps or other electrical loads where a linear voltage output signal is required. The output can be


    Original
    PDF PM-Hx22 PM-Hx22 split core PM-H722LC 7353 transistor H722 PM-H722HC PM-H922LC

    ISS-50

    Abstract: rain sensor electronic hygrometer moisture sensor 0.5 4-20mA TRANGE100 sontay 312-2945 Sontay rh
    Text: Data sheet: 312-2945 Iss.5.0 14/01/2003 s o n t a y 312-2945 Wall Mounting Relative Humidity and Temperature Transmitters Technical Overview The wall mounted combined RH & T sensor provides accurate and reliable measurement for use with a wide range of BMS controllers. The sensing elements


    Original
    PDF 4-20mA 0-10Vdc 0-10Vdc ISS-50 rain sensor electronic hygrometer moisture sensor 0.5 4-20mA TRANGE100 sontay 312-2945 Sontay rh

    Occupancy Sensor

    Abstract: GS-AQ911 810Vdc Sontay rh
    Text: Data Sheet Ref: 90500997 Issue: 5.1 GS-AQ911 Space air quality transmitter www.sontay.com Technical Overview The GS-AQ911 is wall-mounting air quality transmitter designed for use for the control of fresh air for ventilation purposes. The GS-AQ911 measures the level of contaminant


    Original
    PDF GS-AQ911 GS-AQ911 810Vdc. Occupancy Sensor 810Vdc Sontay rh

    ls-541

    Abstract: float switch liquid float level sensor Sontay is 1732 equivalent ls 85 water* pump tank level
    Text: Data Sheet Ref: 90500256 Issue: 5.5 LS-541 Liquid level float switch www.sontay.com Technical Overview The LS-541 is liquid level float switch which is intended to monitor liquid level in a tank or vessel, to provide a switched output to provide local alarm pump or valve control.


    Original
    PDF LS-541 LS-541 10/14mm. 10/14mm float switch liquid float level sensor Sontay is 1732 equivalent ls 85 water* pump tank level

    RH911

    Abstract: TRANGE100 sontay 312-2939 BMS controllers Sontay rh Sontay Sontay RH911
    Text: Data sheet: 312-2939 s o n t a y Iss. 5.0 14/01/2003 312-2939 Space Mounting Relative Humidity and Temperature Transmitters Technical Overview The space mounted combined RH & T sensor provides accurate and reliable measurement for use with a wide range of BMS controllers. An LCD option is


    Original
    PDF 4-20mA 0-10Vdc 4-20mA 0-10vdc RH911 TRANGE100 sontay 312-2939 BMS controllers Sontay rh Sontay Sontay RH911

    BMS controllers

    Abstract: TRANGE100 312-2951 Sontay rh
    Text: Data sheet: 312-2951 Iss.5.0 14/01/2003 s o n t a y 312-2951 Duct Mounting Relative Humidity and Temperature Transmitters Technical Overview The duct mounted combined RH & T sensor provides accurate and reliable measurement for use with a wide range of BMS controllers. The sensing elements


    Original
    PDF 215mm 4-20mA 0-10Vdc 0-10Vdc BMS controllers TRANGE100 312-2951 Sontay rh