SSG08X-1
Abstract: B88069X0240S102
Text: Surge Arrester Components Material Data Sheet Product Family Name SSG08X-1 B88069X0240S102 Date 01.03.2007 Version 2 Construction Element Material group Material CAS if applicable Ceramics Al2O3 1344-28-1 29 Electrode Cu 7440-50-8 45 Inert Gas Ar / Kr / N2 / H2
|
Original
|
SSG08X-1
B88069X0240S102)
2002/95/EC"
2002/95/EC
2005/618/EC)
2005/717/EC;
2005/747/EC,
2006/310/EC)
SSG08X-1
B88069X0240S102
|
PDF
|
SSG08X-1
Abstract: B88069X0240S102
Text: Switching Spark Gap SSG08X-1 Ordering code: B88069X0240S102 Nominal breakdown voltage VN 800 V Initial values 2 Static breakdown voltage VS 1) First ignition value VS, FTE after 24 hours in darkness Following ignition values VS, FIV ≤ 1000 680 . 920 V
|
Original
|
SSG08X-1
B88069X0240S102
SSG08X-1
B88069X0240S102
|
PDF
|
V1-100
Abstract: No abstract text available
Text: Switching Spark Gap SSG08X-1G Ordering code: B88069X0280T502 Nominal breakdown voltage VN 800 V Initial values 2 Static breakdown voltage VS 1) First ignition value VS, FTE after 24 hours in darkness Following ignition values VS, FIV ≤ 1000 680 . 920
|
Original
|
SSG08X-1G
B88069X0280T502
V1-100
|
PDF
|
SSG08X
Abstract: B88069X0280T502 marking CODE VN
Text: Switching Spark Gap SSG08X-1G Ordering code: B88069X0280T502 Nominal breakdown voltage VN 800 V Initial values 2 Static breakdown voltage VS 1) First ignition value VS, FTE after 24 hours in darkness Following ignition values VS, FIV ≤ 1000 680 . 920
|
Original
|
SSG08X-1G
B88069X0280T502
SSG08X
B88069X0280T502
marking CODE VN
|
PDF
|
SSG08X
Abstract: EPCOS 800 B88069X0280T502 SSG08X-1G
Text: Switching Spark Gaps Series/Type: SSG08X-1G The following products presented in this data sheet are being withdrawn. Ordering Code B88069X0280T502 Substitute Product Date of Withdrawal 2003-10-02 Deadline Last Orders 2003-11-01 Last Shipments 2003-12-01 For further information please contact your nearest EPCOS sales office, which will also support
|
Original
|
SSG08X-1G
B88069X0280T502
SSG08X
EPCOS 800
B88069X0280T502
SSG08X-1G
|
PDF
|
Epcos
Abstract: ZKP 180 schematic diagram Electronic Ballast xenon xenon hid ballast diode ZKP epcos SURGE ARRESTERS SURGE ARRESTER spark gap varistor x72 apqp MANUAL A81-A230X
Text: Überspannungsableiter und Schaltfunkenstrecken Surge Arresters and Switching Spark Gaps Produktschrift 2000 / Product Profile 2000 http://www.epcos.com Vorwort Preview Kommunikationseinrichtungen und Systeme zur Datenübertragung können durch Überspannungen und die
|
Original
|
FS08X-1
Q69-X334
Q69-X340
Q69-X329
Q69-X344
Epcos
ZKP 180
schematic diagram Electronic Ballast xenon
xenon hid ballast
diode ZKP
epcos SURGE ARRESTERS
SURGE ARRESTER spark gap
varistor x72
apqp MANUAL
A81-A230X
|
PDF
|
schematic diagram Electronic Ballast xenon
Abstract: diode ZKP ZKP 180 apqp MANUAL epcos SURGE ARRESTERS A80-A230X M51-A230XSMD xenon igniter RAB0203-I circuit diagram ballast xenon
Text: Überspannungsableiter und Schaltfunkenstrecken Surge Arresters and Switching Spark Gaps Produktschrift 2000 / Product Profile 2000 http://www.epcos.com Vorwort Preview Kommunikationseinrichtungen und Systeme zur Datenübertragung können durch Überspannungen und die
|
Original
|
|
PDF
|
SIEMENS svp gas tube
Abstract: B1-A230 b1-c150 B1-A350 siemens spark arrester B1-C90 siemens spark gap N81 Siemens SVP T61-C350 siemens 230 gas discharge tube SVP B1-C90/20 siemens spark arrester
Text: Designing the Future Überspannungen, die u. a. durch atmosphärische Felder und Entladungen Gewitter , Einkoppelungen aus Energieversorgungsleitungen und Schaltvorgänge ausgelöst werden können, dürfen an den hochwertigen Systemen der Nachrichtenübertragung keine Störungen oder Schäden
|
Original
|
|
PDF
|
B1-A350
Abstract: siemens spark arrester B1-C90 siemens spark arrester Siemens SVP T61-C350 B2-B600 SIEMENS svp gas tube b1-c150 siemens spark gap N81 B1A350 B1-A230
Text: Designing the Future Überspannungen, die u. a. durch atmosphärische Felder und Entladungen Gewitter , Einkoppelungen aus Energieversorgungsleitungen und Schaltvorgänge ausgelöst werden können, dürfen an den hochwertigen Systemen der Nachrichtenübertragung keine Störungen oder Schäden
|
Original
|
|
PDF
|