Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TFS125 Search Results

    SF Impression Pixel

    TFS125 Price and Stock

    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Onlinecomponents.com TFS1255A
    • 1 $0
    • 10 $0
    • 100 $0
    • 1000 $0
    • 10000 $0
    Buy Now
    Avnet Silica TFS1255A 10 Weeks 1
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Buy Now
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Onlinecomponents.com TFS1250
    • 1 $0
    • 10 $0
    • 100 $0
    • 1000 $0
    • 10000 $0
    Buy Now
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Ameya Holding Limited TFS125V 2,949
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Get Quote

    Vectron International TFS1255

    BAND PASS FILTER
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Richardson RFPD TFS1255 1
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Get Quote

    Microchip Technology Inc TFS1255C

    SAW filter (Alt: TFS1255C)
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Avnet Silica TFS1255C 10 Weeks 1
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Buy Now

    TFS125 Datasheets (9)

    Part ECAD Model Manufacturer Description Curated Datasheet Type PDF
    TFS125 Vectron International Filter, Passive, RF & IF Original PDF
    TFS125A Vectron International Filter Specification Original PDF
    TFS125B Vectron International Filter Original PDF
    TFS125C Vectron International Filter Specification Original PDF
    TFS125D Vectron International Filter specificationull Original PDF
    TFS125F Vectron International VI TELEFILTER Original PDF
    TFS125G Vectron International Filter Specification Original PDF
    TFS125H Vectron International Filter specification Original PDF
    TFS125K Vectron International Filter Specification TFS 125K Original PDF

    TFS125 Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: Tfs125C.doc version 1.2 VI TELEFILTER 12.07.00 Filter Specification TFS 125C 1/5 Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc: 23 °C 0 dBm input: output: 605 Ω  -11 pF 620 Ω  -11 pF Characteristics


    Original
    Tfs125C PDF

    TFS125

    Abstract: No abstract text available
    Text: tfs125g.doc VI TELEFILTER Filter Specification version 1.2 05.11.2002 TFS 125 G 1/5 Measurement Condition Ambient temperature: Input power level: Source impedance: Load impedance: Terminating impedances: * 23 200 50 input: output: C dBm balanced single ended


    Original
    tfs125g TFS125 PDF

    Untitled

    Abstract: No abstract text available
    Text: tfs125d.doc version 2.0 VI TELEFILTER Filter specification 21.02.2002 TFS 125 D 1/5 Measurement Condition Ambient Temperature: Input Power Level: Source impedance: Load impedance: Terminating impedances: * input: output: 23 °C 0 dBm 50 Ω single ended 50 Ω single ended


    Original
    tfs125d PDF

    TFS125K

    Abstract: No abstract text available
    Text: TFS125K.doc Version 1.2 VI TELEFILTER Filter Specification 18.06.2003 TFS 125K 1/5 Measurement condition Ambient temperature: 23 C Input power level: 0 dBm Terminating impedance’s : 50 Characteristics Remark: Reference level for the relative attenuation arel of the TFS 125K is the maximum attenuation in the pass band. The maximum attenuation in the


    Original
    TFS125K PDF

    TFS125

    Abstract: No abstract text available
    Text: TFS125.doc version 1.0 02/98 Specification TFS 125 - Page 1/2 VI TELEFILTER 1. Measurement Condition


    Original
    TFS125 PDF

    TFS125K

    Abstract: No abstract text available
    Text: TFS125K.doc Version 1.2 VI TELEFILTER Filter Specification 18.06.2003 TFS 125K 1/5 Measurement condition Ambient temperature: 23 °C Input power level: 0 dBm Terminating impedance’s : 50 Ω Characteristics Remark: Reference level for the relative attenuation arel of the TFS 125K is the maximum attenuation in the pass band. The maximum attenuation in the


    Original
    TFS125K PDF

    Untitled

    Abstract: No abstract text available
    Text: Filename: TFS1251.doc Version 3.1 Vectron International 05.02.2015 Filter specification TFS 1251 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: Input: Output: Source: Load: 23 200 200 °C dBm Ω Ω 198.2 Ω | -0.29 pF


    Original
    TFS1251 PDF

    Untitled

    Abstract: No abstract text available
    Text: tfs125B.doc Version 1.0 VI TELEFILTER Filter Specification 06.03.01 TFS 125 B 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedances: 23 50 °C dBm Ω Characteristics Remark: Reference level for the relative attenuation arel of the TFS 125 B is the minimum attenuation in the pass band. The minimum attenuation in the pass


    Original
    tfs125B PDF

    Untitled

    Abstract: No abstract text available
    Text: tfs125a.doc Version 1.3 06.01.02 VI TELEFILTER Filter Specification TFS 125 A - Page 1 / 4


    Original
    tfs125a PDF

    125H

    Abstract: No abstract text available
    Text: tfs125H.doc version 1.2 VI TELEFILTER Filter specification 18.06.2003 TFS 125 H 1/5 Measurement Condition Ambient temperature: Input power level: Source impedance: Load impedance: Terminating impedances: * 23 50 50 input: output: C dBm single ended single ended


    Original
    tfs125H 125H PDF

    125H

    Abstract: No abstract text available
    Text: tfs125H.doc version 1.2 VI TELEFILTER Filter specification 18.06.2003 TFS 125 H 1/5 Measurement Condition Ambient temperature: Input power level: Source impedance: Load impedance: Terminating impedances: * 23 °C 0 dBm 50 Ω single ended 50 Ω single ended


    Original
    tfs125H 125H PDF

    Untitled

    Abstract: No abstract text available
    Text: tfs125a.doc Version 1.3 31.10.00 VI TELEFILTER Filter Specification TFS 125 A - Page 1 / 4


    Original
    tfs125a PDF

    Untitled

    Abstract: No abstract text available
    Text: tfs125g.doc VI TELEFILTER Filter Specification version 1.2 05.11.2002 TFS 125 G 1/5 Measurement Condition 23 °C 0 dBm 200 Ω balanced 50 Ω single ended input: 880 Ω // -11,0 pF output: 890 Ω // -12,6 pF Ambient temperature: Input power level: Source impedance:


    Original
    tfs125g PDF

    Untitled

    Abstract: No abstract text available
    Text: Tfs125F.doc version 1.3 06.01.02 VI TELEFILTER Filter Specification TFS 125F 1/5


    Original
    Tfs125F PDF

    TFS125T

    Abstract: No abstract text available
    Text: Filename: tfs 125t.doc Version 2.0 Vectron International 21.05.2013 Filter specification TFS 125T 1/5 Measurement condition Ambient temperature: Input power level: source impedance balanced : load impedance (balanced): Terminating impedance: * Input: Output:


    Original
    TFS125T PDF

    Untitled

    Abstract: No abstract text available
    Text: Filename: tfs 125s.doc Version 1.1 Vectron International 30.11.2011 Filter specification TFS 125S 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 °C dBm 207 Ω | -24 pF 99 Ω | -25 pF Characteristics


    Original
    TFS125S PDF

    TFS125R

    Abstract: No abstract text available
    Text: Filename: tfs 125r.doc Version 1.1 Vectron International 29.11.2011 Filter specification TFS 125R 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 °C dBm 171 Ω | -13,5 pF 137 Ω | -18,5 pF Characteristics


    Original
    TFS125R PDF

    TFS125P

    Abstract: No abstract text available
    Text: Filename: tfs 125P.doc Version 1.1 Vectron International 28.10.2011 Filter specification TFS 125P 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 °C dBm 115 Ω | -21 pF 110 Ω | -35 pF Characteristics


    Original
    TFS125P PDF